메뉴 건너뛰기




Volumn 19, Issue 7, 2010, Pages 1034-1039

Does slower rehabilitation after arthroscopic rotator cuff repair lead to long-term stiffness?

Author keywords

Case Series; Healing; Immobilization; Level IV; Rehabilitation; Rotator cuff repair; Shoulder; Stiffness; Treatment Study

Indexed keywords

ADULT; AGED; AMERICAN SHOULDER AND LBOW SURGEONS; ARTICLE; CLINICAL ARTICLE; COHORT ANALYSIS; FEMALE; FOLLOW UP; FRACTURE HEALING; HUMAN; IMMOBILIZATION; JOINT MOBILITY; MALE; MUSCULOSKELETAL STIFFNESS; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE CARE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RANGE OF MOTION; RETROSPECTIVE STUDY; ROTATION; ROTATOR CUFF RUPTURE; SCORING SYSTEM; SHOULDER ARTHROSCOPY; TREATMENT OUTCOME;

EID: 77956620236     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2010.04.006     Document Type: Article
Times cited : (160)

References (20)
  • 1
    • 33646203224 scopus 로고    scopus 로고
    • Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study
    • Bishop J., Klepps S., Lo I.K., Bird J., Gladstone J.N., Flatow E.L. Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg 2006, 15:290-299. 10.1016/j.jse.2005.09.017.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 290-299
    • Bishop, J.1    Klepps, S.2    Lo, I.K.3    Bird, J.4    Gladstone, J.N.5    Flatow, E.L.6
  • 2
    • 33846632741 scopus 로고    scopus 로고
    • Complications after arthroscopic rotator cuff repair
    • Brislin K.J., Field L.D., Savoie F.H. Complications after arthroscopic rotator cuff repair. Arthroscopy 2007, 23:124-128. 10.1016/j.arthro.2006.09.001.
    • (2007) Arthroscopy , vol.23 , pp. 124-128
    • Brislin, K.J.1    Field, L.D.2    Savoie, F.H.3
  • 4
    • 0023115201 scopus 로고
    • A clinical method of functional assessment of the shoulder
    • PMID: 3791738
    • Constant C.R., Murley A.H. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 1987, 160-164. PMID: 3791738.
    • (1987) Clin Orthop Relat Res , pp. 160-164
    • Constant, C.R.1    Murley, A.H.2
  • 5
    • 0942279683 scopus 로고    scopus 로고
    • The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears
    • PMID: 14960664
    • Galatz L.M., Ball C.M., Teefey S.A., Middleton W.D., Yamaguchi K. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am 2004, 86:219-224. PMID: 14960664.
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 219-224
    • Galatz, L.M.1    Ball, C.M.2    Teefey, S.A.3    Middleton, W.D.4    Yamaguchi, K.5
  • 6
    • 34447510956 scopus 로고    scopus 로고
    • Long durations of immobilization in the rat result in enhanced mechanical properties of the healing supraspinatus tendon insertion site
    • Gimbel J.A., Van Kleunen J.P., Williams G.R., Thomopoulos S., Soslowsky L.J. Long durations of immobilization in the rat result in enhanced mechanical properties of the healing supraspinatus tendon insertion site. J Biomech Eng 2007, 129:400-404. 10.1115/1.2721075.
    • (2007) J Biomech Eng , vol.129 , pp. 400-404
    • Gimbel, J.A.1    Van Kleunen, J.P.2    Williams, G.R.3    Thomopoulos, S.4    Soslowsky, L.J.5
  • 7
    • 0035161609 scopus 로고    scopus 로고
    • Effect of arm elevation and rotation on the strain in the repaired rotator cuff tendon. A cadaveric study
    • PMID:11734494
    • Hatakeyama Y., Itoi E., Pradhan R.L., Urayama M., Sato K. Effect of arm elevation and rotation on the strain in the repaired rotator cuff tendon. A cadaveric study. Am J Sports Med 2001, 29:788-794. PMID:11734494.
    • (2001) Am J Sports Med , vol.29 , pp. 788-794
    • Hatakeyama, Y.1    Itoi, E.2    Pradhan, R.L.3    Urayama, M.4    Sato, K.5
  • 8
    • 0031847835 scopus 로고    scopus 로고
    • Continuous passive motion after repair of the rotator cuff. A prospective outcome study
    • PMID: 9698005
    • Lastayo P.C., Wright T., Jaffe R., Hartzel J. Continuous passive motion after repair of the rotator cuff. A prospective outcome study. J Bone Joint Surg Am 1998, 80:1002-1011. PMID: 9698005.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1002-1011
    • Lastayo, P.C.1    Wright, T.2    Jaffe, R.3    Hartzel, J.4
  • 9
    • 34547748291 scopus 로고    scopus 로고
    • Magnetic resonance imaging of arthroscopic supraspinatus tendon repair
    • Liem D., Lichtenberg S., Magosch P., Habermeyer P. Magnetic resonance imaging of arthroscopic supraspinatus tendon repair. J Bone Joint Surg Am 2007, 89:1770-1776. 10.2106/JBJS.F.00749.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 1770-1776
    • Liem, D.1    Lichtenberg, S.2    Magosch, P.3    Habermeyer, P.4
  • 11
    • 33845472441 scopus 로고    scopus 로고
    • Rehabilitation of the rotator cuff: an evaluation-based approach
    • PMID: 17030593
    • Millett P.J., Wilcox R.B., O'Holleran J.D., Warner J.J. Rehabilitation of the rotator cuff: an evaluation-based approach. J Am Acad Orthop Surg 2006, 14:599-609. PMID: 17030593.
    • (2006) J Am Acad Orthop Surg , vol.14 , pp. 599-609
    • Millett, P.J.1    Wilcox, R.B.2    O'Holleran, J.D.3    Warner, J.J.4
  • 12
    • 0029789335 scopus 로고    scopus 로고
    • Captured shoulder: a complication of rotator cuff surgery
    • Mormino M.A., Gross R.M., McCarthy J.A. Captured shoulder: a complication of rotator cuff surgery. Arthroscopy 1996, 12:457-461. 10.1016/S0749-8063(96)90040-7.
    • (1996) Arthroscopy , vol.12 , pp. 457-461
    • Mormino, M.A.1    Gross, R.M.2    McCarthy, J.A.3
  • 13
    • 0033977565 scopus 로고    scopus 로고
    • Repair of the rotator cuff. Mini-open and arthroscopic repairs
    • Norberg F.B., Field L.D., Savoie F.H. Repair of the rotator cuff. Mini-open and arthroscopic repairs. Clin Sports Med 2000, 19:77-99. 10.1016/S0278-5919(05)70297-0.
    • (2000) Clin Sports Med , vol.19 , pp. 77-99
    • Norberg, F.B.1    Field, L.D.2    Savoie, F.H.3
  • 14
    • 0030008219 scopus 로고    scopus 로고
    • Early results of continuous passive motion after rotator cuff repair: a prospective, randomized, blinded, controlled study
    • PMID: 8775698
    • Raab M.G., Rzeszutko D., O'Connor W., Greatting M.D. Early results of continuous passive motion after rotator cuff repair: a prospective, randomized, blinded, controlled study. Am J Orthop 1996, 25:214-220. PMID: 8775698.
    • (1996) Am J Orthop , vol.25 , pp. 214-220
    • Raab, M.G.1    Rzeszutko, D.2    O'Connor, W.3    Greatting, M.D.4
  • 16
    • 0031006780 scopus 로고    scopus 로고
    • A biomechanical evaluation of suture anchors in repair of the rotator cuff
    • Rossouw D.J., McElroy B.J., Amis A.A., Emery R.J. A biomechanical evaluation of suture anchors in repair of the rotator cuff. J Bone Joint Surg Br 1997, 79:458-461. 10.1302/0301-620X.79B3.6983.
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 458-461
    • Rossouw, D.J.1    McElroy, B.J.2    Amis, A.A.3    Emery, R.J.4
  • 17
    • 38049165928 scopus 로고    scopus 로고
    • After rotator cuff repair, stiffness-but not the loss in range of motion-increased transiently for immobilized shoulders in a rat model
    • Sarver J.J., Peltz C.D., Dourte L., Reddy S., Williams G.R., Soslowsky L.J. After rotator cuff repair, stiffness-but not the loss in range of motion-increased transiently for immobilized shoulders in a rat model. J Shoulder Elbow Surg 2008, 17:108S-113S. 10.1016/j.jse.2007.08.004.
    • (2008) J Shoulder Elbow Surg , vol.17
    • Sarver, J.J.1    Peltz, C.D.2    Dourte, L.3    Reddy, S.4    Williams, G.R.5    Soslowsky, L.J.6
  • 18
    • 0037291271 scopus 로고    scopus 로고
    • Tendon to bone healing: differences in biomechanical, structural, and compositional properties due to a range of activity levels
    • Thomopoulos S., Williams G.R., Soslowsky L.J. Tendon to bone healing: differences in biomechanical, structural, and compositional properties due to a range of activity levels. J Biomech Eng 2003, 125:106-113. 10.1115/1.1536660.
    • (2003) J Biomech Eng , vol.125 , pp. 106-113
    • Thomopoulos, S.1    Williams, G.R.2    Soslowsky, L.J.3
  • 19
    • 11844275235 scopus 로고    scopus 로고
    • Prevention of shoulder stiffness after rotator cuff repair
    • Trenerry K., Walton J.R., Murrell G.A. Prevention of shoulder stiffness after rotator cuff repair. Clin Orthop Relat Res 2005, 94-99. 10.1097/01.blo.0000137564.27841.27.
    • (2005) Clin Orthop Relat Res , pp. 94-99
    • Trenerry, K.1    Walton, J.R.2    Murrell, G.A.3
  • 20
    • 0036488125 scopus 로고    scopus 로고
    • Complications associated with arthroscopic shoulder surgery
    • Weber S.C., Abrams J.S., Nottage W.M. Complications associated with arthroscopic shoulder surgery. Arthroscopy 2002, 18:88-95. 10.1016/S0749-8063(02)80008-1.
    • (2002) Arthroscopy , vol.18 , pp. 88-95
    • Weber, S.C.1    Abrams, J.S.2    Nottage, W.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.