메뉴 건너뛰기




Volumn 19, Issue 7, 2010, Pages 1085-1090

Integrity and function of the subscapularis after total shoulder arthroplasty

Author keywords

Bear hug; Case Series; Integrity; Lesser tuberosity; Level IV; Osteotomy; Physical examination; Shoulder; Subscapularis; Total shoulder arthroplasty; Ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; BONE RADIOGRAPHY; CLINICAL ARTICLE; DYNAMOMETRY; FEMALE; FOLLOW UP; HUMAN; ISOKINETIC EXERCISE; ISOMETRIC EXERCISE; JOINT MOBILITY; MALE; OSTEOARTHRITIS; OUTCOME ASSESSMENT; PHYSICAL EXAMINATION; POSTOPERATIVE CARE; PRIORITY JOURNAL; SCAPULA; SCORING SYSTEM; SHOULDER ARTHROPLASTY; SHOULDER INJURY; SUBLUXATION; SUBSCAPULARIS TEAR; TENOTOMY;

EID: 77956611768     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2010.04.001     Document Type: Article
Times cited : (116)

References (21)
  • 1
    • 33748539053 scopus 로고    scopus 로고
    • Ultrasound evaluation and clinical correlation of subscapularis repair after total shoulder arthroplasty
    • Armstrong A., Lashgari C., Teefey S., Menendez J., Yamaguchi K., Galatz L.M. Ultrasound evaluation and clinical correlation of subscapularis repair after total shoulder arthroplasty. J Shoulder Elbow Surg 2006, 15:541-548. 10.1016/j.jse.2005.09.013.
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 541-548
    • Armstrong, A.1    Lashgari, C.2    Teefey, S.3    Menendez, J.4    Yamaguchi, K.5    Galatz, L.M.6
  • 2
    • 33749248822 scopus 로고    scopus 로고
    • The bear-hug test: a new and sensitive test for diagnosing a subscapularis tear
    • Barth J.R., Burkhart S.S., De Beer J.F. The bear-hug test: a new and sensitive test for diagnosing a subscapularis tear. Arthroscopy 2006, 22:1076-1084. 10.1016/j.arthro2006.05.005.
    • (2006) Arthroscopy , vol.22 , pp. 1076-1084
    • Barth, J.R.1    Burkhart, S.S.2    De Beer, J.F.3
  • 3
    • 60649093058 scopus 로고    scopus 로고
    • Subscapularis function after primary tendon to tendon repair in patients after replacement arthroplasty of the shoulder
    • Caplan J.L., Whitfield B., Neviaser R.J. Subscapularis function after primary tendon to tendon repair in patients after replacement arthroplasty of the shoulder. J Shoulder Elbow Surg 2009, 18:193-196. 10.1016/j.jse.2008.10.019.
    • (2009) J Shoulder Elbow Surg , vol.18 , pp. 193-196
    • Caplan, J.L.1    Whitfield, B.2    Neviaser, R.J.3
  • 4
    • 0021269585 scopus 로고
    • Total shoulder arthroplasty with the Neer prosthesis
    • Cofield R.H. Total shoulder arthroplasty with the Neer prosthesis. J Bone Joint Surg Am 1984, 66A:899-906.
    • (1984) J Bone Joint Surg Am , vol.66 A , pp. 899-906
    • Cofield, R.H.1
  • 5
    • 0030111271 scopus 로고    scopus 로고
    • Sonographic detection of tears of the anterior portion of the rotator cuff (subscapularis tendon tears)
    • PMID:8919503
    • Farin P., Jaroma H. Sonographic detection of tears of the anterior portion of the rotator cuff (subscapularis tendon tears). J Ultrasound Med 1996, 15:221-225. PMID:8919503.
    • (1996) J Ultrasound Med , vol.15 , pp. 221-225
    • Farin, P.1    Jaroma, H.2
  • 6
    • 0030036715 scopus 로고    scopus 로고
    • Isolated rupture of the subscapularis tendon
    • Gerber C., Hersche O., Farron A. Isolated rupture of the subscapularis tendon. J Bone Joint Surg Am 1996, 78A:1015-1023.
    • (1996) J Bone Joint Surg Am , vol.78 A , pp. 1015-1023
    • Gerber, C.1    Hersche, O.2    Farron, A.3
  • 7
    • 0025774901 scopus 로고
    • Isolated rupture of the tendon of the subscapularis muscle. Clinical features in 16 cases
    • Gerber C., Krushell R.J. Isolated rupture of the tendon of the subscapularis muscle. Clinical features in 16 cases. J Bone Joint Surg Br 1991, 73B:389-394.
    • (1991) J Bone Joint Surg Br , vol.73 B , pp. 389-394
    • Gerber, C.1    Krushell, R.J.2
  • 8
    • 23044508920 scopus 로고    scopus 로고
    • Subscapularis muscle function and structure after total shoulder replacement with lesser tuberosity osteotomy and repair
    • Gerber C., Yian E.H., Pfirrmann C.A., Zumstein M.A., Werner C.M. Subscapularis muscle function and structure after total shoulder replacement with lesser tuberosity osteotomy and repair. J Bone Joint Surg Am 2005, 87A:1739-1745. 10.2106/JBJS.D.02788.
    • (2005) J Bone Joint Surg Am , vol.87 A , pp. 1739-1745
    • Gerber, C.1    Yian, E.H.2    Pfirrmann, C.A.3    Zumstein, M.A.4    Werner, C.M.5
  • 9
    • 0029738607 scopus 로고    scopus 로고
    • Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand). The Upper Extremity Collaborative Group (UECG)
    • 6<602::AID-AJIM4>3.0.CO;2-L
    • Hudak P.L., Amadio P.C., Bombardier C. Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand). The Upper Extremity Collaborative Group (UECG). Am J Ind Med 1996, 29:602-608. 6<602::AID-AJIM4>3.0.CO;2-L. 10.1002/(SICI)1097-0274(199606)29.
    • (1996) Am J Ind Med , vol.29 , pp. 602-608
    • Hudak, P.L.1    Amadio, P.C.2    Bombardier, C.3
  • 10
    • 25444518438 scopus 로고    scopus 로고
    • Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome
    • Miller B.S., Joseph T.A., Noonan T.J., Horan M.P., Hawkins R.J. Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome. J Shoulder Elbow Surg 2005, 14:492-496. 10.1016/j.jse.2005.02.013.
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 492-496
    • Miller, B.S.1    Joseph, T.A.2    Noonan, T.J.3    Horan, M.P.4    Hawkins, R.J.5
  • 11
    • 0038390310 scopus 로고    scopus 로고
    • Loss of subscapularis function after total shoulder replacement: A seldom recognized problem
    • Miller S.L., Hazrati Y., Klepps S., Chiang A., Flatow E.L. Loss of subscapularis function after total shoulder replacement: A seldom recognized problem. J Shoulder Elbow Surg 2003, 1:29-34. 10.1067/mse.2003.128195.
    • (2003) J Shoulder Elbow Surg , vol.1 , pp. 29-34
    • Miller, S.L.1    Hazrati, Y.2    Klepps, S.3    Chiang, A.4    Flatow, E.L.5
  • 14
    • 28544444609 scopus 로고    scopus 로고
    • Biomechanical and clinical evaluation of a novel lesser tuberosity repair technique in total shoulder arthroplasty
    • Ponce B.A., Ahluwalia R.S., Mazzocca A.D., Bobezie R.G., Warner J.J., Millet P.J. Biomechanical and clinical evaluation of a novel lesser tuberosity repair technique in total shoulder arthroplasty. J Bone Joint Surg Am 2005, 87A(Suppl 2):1-8. 10.2106/JBJS.E.00441.
    • (2005) J Bone Joint Surg Am , vol.87 A , Issue.SUPPL. 2 , pp. 1-8
    • Ponce, B.A.1    Ahluwalia, R.S.2    Mazzocca, A.D.3    Bobezie, R.G.4    Warner, J.J.5    Millet, P.J.6
  • 15
    • 41649101064 scopus 로고    scopus 로고
    • Subscapularis function after total shoulder replacement: results with lesser tuberosity osteotomy
    • Qureshi S., Hsiao A., Klug R.A., Lee E., Braman J., Flatow E. Subscapularis function after total shoulder replacement: results with lesser tuberosity osteotomy. J Shoulder Elbow Surg 2008, 17:68-72. 10.1016/j.jse.2007.04.018.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 68-72
    • Qureshi, S.1    Hsiao, A.2    Klug, R.A.3    Lee, E.4    Braman, J.5    Flatow, E.6
  • 17
    • 0038475793 scopus 로고    scopus 로고
    • Sonographic evaluation of shoulder arthroplasty
    • PMID:12646465
    • Sofka C.M., Adler R.S. Sonographic evaluation of shoulder arthroplasty. AJR Am J Roentgenol 2003, 180:1117-1120. PMID:12646465.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 1117-1120
    • Sofka, C.M.1    Adler, R.S.2
  • 19
    • 0034076924 scopus 로고    scopus 로고
    • Ultrasonography of the rotator cuff. A comparison of ultrasonographic and arthroscopic findings in one hundred consecutive cases
    • Teefey S.A., Hasan S.A., Middleton W.D., Patel M., Wright R.W., Yamaguchi K. Ultrasonography of the rotator cuff. A comparison of ultrasonographic and arthroscopic findings in one hundred consecutive cases. J Bone Joint Surg Am 2000, 82A:498-504.
    • (2000) J Bone Joint Surg Am , vol.82 A , pp. 498-504
    • Teefey, S.A.1    Hasan, S.A.2    Middleton, W.D.3    Patel, M.4    Wright, R.W.5    Yamaguchi, K.6
  • 20
    • 20044377610 scopus 로고    scopus 로고
    • Detection and measurement of rotator cuff tears with sonography: analysis of diagnostic errors
    • PMID:15908528
    • Teefey S.A., Middleton W.D., Payne W.T., Yamaguchi K. Detection and measurement of rotator cuff tears with sonography: analysis of diagnostic errors. AJR Am J Roentgenol 2005, 184:1768-1773. PMID:15908528.
    • (2005) AJR Am J Roentgenol , vol.184 , pp. 1768-1773
    • Teefey, S.A.1    Middleton, W.D.2    Payne, W.T.3    Yamaguchi, K.4
  • 21
    • 1842578965 scopus 로고    scopus 로고
    • Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases
    • Teefey S.A., Rubin D.A., Middleton W.D., Hildebolt C.F., Leibold R.A., Yamaguchi K. Detection and quantification of rotator cuff tears. Comparison of ultrasonographic, magnetic resonance imaging, and arthroscopic findings in seventy-one consecutive cases. J Bone Joint Surg Am 2004, 86A:708-716.
    • (2004) J Bone Joint Surg Am , vol.86 A , pp. 708-716
    • Teefey, S.A.1    Rubin, D.A.2    Middleton, W.D.3    Hildebolt, C.F.4    Leibold, R.A.5    Yamaguchi, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.