메뉴 건너뛰기




Volumn 411, Issue 21-22, 2010, Pages 1728-1734

An automated turbulent flow liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method for quantitation of serum creatinine

Author keywords

Creatinine; Liquid chromatography isotope dilution mass spectrometry; Turbulent flow

Indexed keywords

CREATININE;

EID: 77956470874     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2010.07.013     Document Type: Article
Times cited : (52)

References (9)
  • 1
    • 19944429161 scopus 로고    scopus 로고
    • Excerpts from the United States Renal Data System 2004 annual data report: atlas of end-stage renal disease in the United States
    • J, A5-7, S1-280
    • Collins A.J., Kasiske B., Herzog C., Chavers B., Foley R., Gilbertson D., et al. Excerpts from the United States Renal Data System 2004 annual data report: atlas of end-stage renal disease in the United States. Am J Kidney Dis Jan 2005, 45(1 Suppl 1). A5-7, S1-280.
    • (2005) Am J Kidney Dis , vol.45 , Issue.1 SUPPL 1
    • Collins, A.J.1    Kasiske, B.2    Herzog, C.3    Chavers, B.4    Foley, R.5    Gilbertson, D.6
  • 2
    • 29744469415 scopus 로고    scopus 로고
    • Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program
    • J
    • Myers G.L., Miller W.G., Coresh J., Fleming J., Greenberg N., Greene T., et al. Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem Jan 2006, 52(1):5-18.
    • (2006) Clin Chem , vol.52 , Issue.1 , pp. 5-18
    • Myers, G.L.1    Miller, W.G.2    Coresh, J.3    Fleming, J.4    Greenberg, N.5    Greene, T.6
  • 3
    • 14844325792 scopus 로고    scopus 로고
    • Creatinine measurement: state of the art in accuracy and interlaboratory harmonization
    • M
    • Miller W.G., Myers G.L., Ashwood E.R., Killeen A.A., Wang E., Thienpont L.M., et al. Creatinine measurement: state of the art in accuracy and interlaboratory harmonization. Arch Pathol Lab Med Mar 2005, 129(3):297-304.
    • (2005) Arch Pathol Lab Med , vol.129 , Issue.3 , pp. 297-304
    • Miller, W.G.1    Myers, G.L.2    Ashwood, E.R.3    Killeen, A.A.4    Wang, E.5    Thienpont, L.M.6
  • 4
    • 0000841697 scopus 로고
    • Ueber den Niederschlag, welchen Pikrinsäure in normalem Harn erzeugt und über eine neune Reaktion des Kreatinins
    • Jaffe M. Ueber den Niederschlag, welchen Pikrinsäure in normalem Harn erzeugt und über eine neune Reaktion des Kreatinins. Z Physiol Chem 1886, 10:391-400.
    • (1886) Z Physiol Chem , vol.10 , pp. 391-400
    • Jaffe, M.1
  • 5
    • 0030995225 scopus 로고    scopus 로고
    • Positive interference with the Jaffe reaction by cefpirome
    • M
    • Kerr J.R., Ferguson W.P., Archbold P. Positive interference with the Jaffe reaction by cefpirome. Intensive Care Med Mar 1997, 23(3):357-358.
    • (1997) Intensive Care Med , vol.23 , Issue.3 , pp. 357-358
    • Kerr, J.R.1    Ferguson, W.P.2    Archbold, P.3
  • 6
    • 0031962367 scopus 로고    scopus 로고
    • Mechanisms of dopamine and dobutamine interference in biochemical tests that use peroxide and peroxidase to generate chromophore
    • J
    • Karon B.S., Daly T.M., Scott M.G. Mechanisms of dopamine and dobutamine interference in biochemical tests that use peroxide and peroxidase to generate chromophore. Clin Chem Jan 1998, 44(1):155-160.
    • (1998) Clin Chem , vol.44 , Issue.1 , pp. 155-160
    • Karon, B.S.1    Daly, T.M.2    Scott, M.G.3
  • 7
    • 0022750054 scopus 로고
    • Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method
    • J
    • Welch M.J., Cohen A., Hertz H.S., Ng K.J., Schaffer R., Van der Lijn P., et al. Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method. Anal Chem Jul 1986, 58(8):1681-1685.
    • (1986) Anal Chem , vol.58 , Issue.8 , pp. 1681-1685
    • Welch, M.J.1    Cohen, A.2    Hertz, H.S.3    Ng, K.J.4    Schaffer, R.5    Van der Lijn, P.6
  • 8
    • 0042347707 scopus 로고    scopus 로고
    • Development of a liquid chromatography-mass spectrometry method for the high-accuracy determination of creatinine in serum
    • A
    • Stokes P., O'Connor G. Development of a liquid chromatography-mass spectrometry method for the high-accuracy determination of creatinine in serum. J Chromatogr B Anal Technol Biomed Life Sci Aug 2003, 794(1):125-136.
    • (2003) J Chromatogr B Anal Technol Biomed Life Sci , vol.794 , Issue.1 , pp. 125-136
    • Stokes, P.1    O'Connor, G.2
  • 9
    • 33644696674 scopus 로고    scopus 로고
    • Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods
    • M
    • Owen L.J., Wear J.E., Keevil B.G. Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods. Ann Clin Biochem Mar 2006, 43(Pt 2):118-123.
    • (2006) Ann Clin Biochem , vol.43 , Issue.PART 2 , pp. 118-123
    • Owen, L.J.1    Wear, J.E.2    Keevil, B.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.