Non-contact reflection photoplethysmography towards effective human physiological monitoring

Author keywords

Bland altman plot; Cardio physiological monitoring; Non contact reflection photoplethysmography (NRPPG); Pearson's correlation; Sensor placement

Indexed keywords

BLAND-ALTMAN PLOT; NON-CONTACT; PEARSON'S CORRELATION; PHYSIOLOGICAL MONITORING; SENSOR PLACEMENT;

EID: 77956470617     PISSN: 16090985     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (18)
  • 1
    • 0000126622 scopus 로고
    • Observations on the finger volume pulse recorded photoelectrically
    • A. B. Hertzman and C. R. Spealman, "Observations on the finger volume pulse recorded photoelectrically," Am. J. Physiol. Meas., 119: 334-335, 1937.
    • (1937) Am. J. Physiol. Meas. , vol.119 , pp. 334-335
    • Hertzman, A.B.1    Spealman, C.R.2
  • 2
    • 0031910258 scopus 로고    scopus 로고
    • The variability of the photoplethysmographic signal: A potential method for the evaluation of the autonomic nervous system
    • M. Nitzan, A. Babchenko, B. Khanokh and D. Landau, "The variability of the photoplethysmographic signal: a potential method for the evaluation of the autonomic nervous system," Physiol. Meas., 19: 93-102, 1998.
    • (1998) Physiol. Meas. , vol.19 , pp. 93-102
    • Nitzan, M.1    Babchenko, A.2    Khanokh, B.3    Landau, D.4
  • 4
    • 77950990298 scopus 로고    scopus 로고
    • Doctoral Thesis, Loughborough University, Leicestershire, United Kingdom
    • M. Hayes, "Artefact reduction in photoplethysmography," Doctoral Thesis, Loughborough University, Leicestershire, United Kingdom, 1998.
    • (1998) Artefact Reduction in Photoplethysmography
    • Hayes, M.1
  • 7
    • 23844526783 scopus 로고    scopus 로고
    • Contactless multiple wavelength photoplethysmographic imaging: A first step toward "SpO2 camera" technology
    • F. P. Wieringa, F. Mastik and A. F. van der Steen, "Contactless multiple wavelength photoplethysmographic imaging: a first step toward "SpO2 camera" technology," Ann. Biomed. Eng., 33: 1034-1041, 2005.
    • (2005) Ann. Biomed. Eng. , vol.33 , pp. 1034-1041
    • Wieringa, F.P.1    Mastik, F.2    Van Der Steen, A.F.3
  • 8
    • 33645355756 scopus 로고    scopus 로고
    • Artifact reduction in Photoplethysmography
    • International Patent, WO/1999/032030
    • P. R. Smith and M. J. Hayes, "Artifact reduction in Photoplethysmography," International Patent, WO/1999/032030, 1999.
    • (1999)
    • Smith, P.R.1    Hayes, M.J.2
  • 9
    • 0026629967 scopus 로고
    • Pulse oximetry: Theory and applications for noninvasive monitoring
    • Y. Mendelson, "Pulse oximetry: theory and applications for noninvasive monitoring," Clin. Chem., 38: 1601-1607, 1992.
    • (1992) Clin. Chem. , vol.38 , pp. 1601-1607
    • Mendelson, Y.1
  • 10
    • 0001012726 scopus 로고
    • Photon migration in the presence of a single defect: A perturbation analysis
    • S. Feng, F. Zeng, and B. Chance, "Photon migration in the presence of a single defect: a perturbation analysis," App. Opt., 34: 3826-3837 1995.
    • (1995) App. Opt. , vol.34 , pp. 3826-3837
    • Feng, S.1    Zeng, F.2    Chance, B.3
  • 11
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • J. Allen, "Photoplethysmography and its application in clinical physiological measurement," Physiol. Meas., 28: R1-39, 2007.
    • (2007) Physiol. Meas. , vol.28
    • Allen, J.1
  • 14
    • 84908219488 scopus 로고
    • Statistical method for assessing agreement between two methods of clinical measurement
    • J. M. Bland and D. G. Altman, "Statistical method for assessing agreement between two methods of clinical measurement," Lancet, 1: 307-310, 1986.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • J. M. Bland and D. G. Altman, "Measuring agreement in method comparison studies," Stat. Methods Med. Res., 8: 135-60, 1999.
    • (1999) Stat. Methods Med. Res. , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0027236104 scopus 로고
    • The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia
    • S. J. Barker, J. Hyatt, N. K. Shah, and Y. J. Kao, "The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia," Anesthesiology, 79: 248-254, 1993.
    • (1993) Anesthesiology , vol.79 , pp. 248-254
    • Barker, S.J.1    Hyatt, J.2    Shah, N.K.3    Kao, Y.J.4
  • 17
    • 0004157622 scopus 로고    scopus 로고
    • Bristol, UK: Institute of Physics Publishing
    • J. G. Webster (Ed.), Design of Pulse Oximeters, Bristol, UK: Institute of Physics Publishing, 1997.
    • (1997) Design of Pulse Oximeters
    • Webster, J.G.1
  • 18
    • 0002480057 scopus 로고    scopus 로고
    • Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head
    • E. Okada, M. Firbank, M. Schweiger, S. R. Arridge, M. Cope, and D. T. Delpy, "Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head," Appl. Opt., 36: 21-31, 1997.
    • (1997) Appl. Opt. , vol.36 , pp. 21-31
    • Okada, E.1    Firbank, M.2    Schweiger, M.3    Arridge, S.R.4    Cope, M.5    Delpy, D.T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.