메뉴 건너뛰기




Volumn 7, Issue 5, 2010, Pages 599-604

Titanium-nitride-oxide-coated Titan-2 bioactive coronary stent: A new horizon for coronary intervention

Author keywords

bioactive stents; drug eluting stents; in stent restenosis; percutaneous coronary intervention; stent thrombosis

Indexed keywords

BIOACTIVE STENTS; DRUG-ELUTING STENTS; IN-STENT RESTENOSIS; PERCUTANEOUS CORONARY INTERVENTION; STENT THROMBOSIS;

EID: 77956466755     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/erd.10.44     Document Type: Review
Times cited : (4)

References (37)
  • 1
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys PW, de Jaegere P, Kiemeneij F et al. A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N. Engl. J. Med. 331, 489-495 (1994).
    • (1994) N. Engl. J. Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    De Jaegere, P.2    Kiemeneij, F.3
  • 2
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fischman DL, Leon MB, Baim DS et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N. Engl. J. Med. 331, 496-501 (1994).
    • (1994) N. Engl. J. Med , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 5
    • 0031670506 scopus 로고    scopus 로고
    • The influnce of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation
    • Abizaid A, Kornowski R, Mintz GS et al. The influnce of diabetes mellitus on acute and late clinical outcomes following coronary stent implantation. J. Am. Coll. Cardiol. 32, 584-589 (1998).
    • (1998) J. Am. Coll. Cardiol , vol.32 , pp. 584-589
    • Abizaid, A.1    Kornowski, R.2    Mintz, G.S.3
  • 7
    • 9144249927 scopus 로고    scopus 로고
    • A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
    • Stone GW, Ellis SG, Cox DA et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N. Engl. J. Med. 350, 221-231 (2004).
    • (2004) N. Engl. J. Med , vol.350 , pp. 221-231
    • Stone, G.W.1    Ellis, S.G.2    Cox, D.A.3
  • 8
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N. Engl. J. Med. 349, 1315-1323 (2003).
    • (2003) N. Engl. J. Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 9
    • 34147176083 scopus 로고    scopus 로고
    • Stent thrombosis late after implantation of first generation drug-eluting stents: A cause for concern
    • Camenzind E, Steg PG, Wijns W. Stent thrombosis late after implantation of first generation drug-eluting stents: a cause for concern. Circulation 115, 1440-1455 (2007).
    • (2007) Circulation , vol.115 , pp. 1440-1455
    • Camenzind, E.1    Steg, P.G.2    Wijns, W.3
  • 10
    • 33847762819 scopus 로고    scopus 로고
    • Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden
    • Lagerqvist B, James SK, Stenestrand U et al. Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden. N. Engl. J. Med. 356, 1009-1019 (2007).
    • (2007) N. Engl. J. Med , vol.356 , pp. 1009-1019
    • Lagerqvist, B.1    James, S.K.2    Stenestrand, U.3
  • 11
    • 33751247472 scopus 로고    scopus 로고
    • Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: A meta-analysis
    • Nordmann AJ, Briel M, Bucher HC. Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysis. Eur. Heart J. 27, 2784-2814 (2006).
    • (2006) Eur. Heart J , vol.27 , pp. 2784-2814
    • Nordmann, A.J.1    Briel, M.2    Bucher, H.C.3
  • 12
    • 21144436791 scopus 로고    scopus 로고
    • Randomized comparison of a titanium-nitride oxide-coated stent with a stainless steel stent for coronary revascularization. The TINOX trial
    • Windecker S, Simon R, Lins M et al. Randomized comparison of a titanium-nitride oxide-coated stent with a stainless steel stent for coronary revascularization. The TINOX trial. Circulation 111, 2617-2622 (2005).
    • (2005) Circulation , vol.111 , pp. 2617-2622
    • Windecker, S.1    Simon, R.2    Lins, M.3
  • 13
    • 33947315603 scopus 로고    scopus 로고
    • Real world experience with the TITAN stent: A 9-month follow-up report from the Titan PORI registry
    • Karjalainen PP, Ylitalo A, Airaksinen KE. Real world experience with the TITAN stent: a 9-month follow-up report from the Titan PORI registry. EuroInterv. 2, 187-191 (2006).
    • (2006) EuroInterv , vol.2 , pp. 187-191
    • Karjalainen, P.P.1    Ylitalo, A.2    Airaksinen, K.E.3
  • 14
    • 66449097563 scopus 로고    scopus 로고
    • The titanium-NO stent: Results of a multicenter registry
    • Mosseri M, Miller H, Tamari I et al. The titanium-NO stent: results of a multicenter registry. EuroInterv. 2, 192-196 (2006).
    • (2006) EuroInterv , vol.2 , pp. 192-196
    • Mosseri, M.1    Miller, H.2    Tamari, I.3
  • 15
    • 24344433399 scopus 로고    scopus 로고
    • Short and long term outcome of the Titanium- NO stent registry
    • Mosseri M, Tamari I, Plich M et al. Short and long term outcome of the Titanium- NO stent registry. Cardiovasc. Revasc. Med. 6(1), 2-6 (2005).
    • (2005) Cardiovasc. Revasc. Med , vol.6 , Issue.1 , pp. 2-6
    • Mosseri, M.1    Tamari, I.2    PliMielke, C.H.3
  • 16
    • 72949123374 scopus 로고    scopus 로고
    • Titan 2 bio-active stent (BAS) with titanium-NO
    • Giraud-Sauveur Y. Titan 2 bio-active stent (BAS) with titanium-NO. EuroInterv. 3, 526-528 (2007).
    • (2007) EuroInterv , vol.3 , pp. 526-528
    • Giraud-Sauveur, Y.1
  • 17
    • 33749353486 scopus 로고    scopus 로고
    • Titanium and nitride oxide-coated stents and paclitaxel-eluting stents for coronary revascularization in an unselected population
    • Karjalainen PP, Ylitalo A, Airaksinen JK. Titanium and nitride oxide-coated stents and paclitaxel-eluting stents for coronary revascularization in an unselected population. J. Invasive Cardiol. 18, 462-468 (2006).
    • (2006) J. Invasive Cardiol , vol.18 , pp. 462-468
    • Karjalainen, P.P.1    Ylitalo, A.2    Airaksinen, J.K.3
  • 18
    • 77957857703 scopus 로고    scopus 로고
    • Long-term clinical outcome with titanium-nitride-oxide-coated stents and paclitaxel-eluting stents for coronary revascularization in an unselected population
    • DOI: 10.1016/j.ijcard.2009.03.120 In press
    • Karjalainen PP, Annala AP, Ylitalo A, Vahlberg T, Airaksinen KE. Long-term clinical outcome with titanium-nitride-oxide-coated stents and paclitaxel-eluting stents for coronary revascularization in an unselected population. Int. J. Cardiol. DOI: 10.1016/j.ijcard.2009.03.120 (2009) (In press).
    • (2009) Int. J. Cardiol
    • Karjalainen, P.P.1    Annala, A.P.2    Ylitalo, A.3    Vahlberg, T.4    Airaksinen, K.E.5
  • 19
    • 59049086639 scopus 로고    scopus 로고
    • Titanium-nitride-oxide coated stents versus paclitaxel-eluting stents in acute myocardial infarction: A 12-months follow-up report from the TITAX AMI trial
    • Karjalainen PP, Ylitalo A, Niemel M et al. Titanium-nitride-oxide coated stents versus paclitaxel-eluting stents in acute myocardial infarction: a 12-months follow-up report from the TITAX AMI trial. EuroInterv 4(2), 234-241 (2008).
    • (2008) EuroInterv , vol.4 , Issue.2 , pp. 234-241
    • Karjalainen, P.P.1    Ylitalo, A.2    Niemel, M.3
  • 20
    • 77955166800 scopus 로고    scopus 로고
    • Two-year follow-up after percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus paclitaxel-eluting stents in acute myocardial infarction
    • Karjalainen PP, Ylitalo A, Niemela M et al. Two-year follow-up after percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus paclitaxel-eluting stents in acute myocardial infarction. Ann. Med. 21, 1-9 (2009).
    • (2009) Ann. Med , vol.21 , pp. 1-9
    • Karjalainen, P.P.1    Ylitalo, A.2    Niemela, M.3
  • 21
    • 0030339091 scopus 로고    scopus 로고
    • Metal implants and surface reactions
    • Steinemann SG. Metal implants and surface reactions. Injury 27, SC16-22 (1996).
    • (1996) Injury , vol.27
    • Steinemann, S.G.1
  • 23
    • 0032189569 scopus 로고    scopus 로고
    • In vivo investigation of blood compatibility of titanium oxide films
    • DOI 10.1002/(SICI)1097-4636(199810)42:1<128::AID-JBM16>3.0.CO;2-H
    • Zhang F, Zheng Z, Chen Y, Liu X, Chen A, Jiang Z. In vivo investigation of blood compatibility of titanium oxide films. J. Biomed. Mater. Res. 42(1), 128-133 (1998). (Pubitemid 28413005)
    • (1998) Journal of Biomedical Materials Research , vol.42 , Issue.1 , pp. 128-133
    • Zhang, F.1    Zheng, Z.2    Chen, Y.3    Liu, X.4    Chen, A.5    Jiang, Z.6
  • 25
    • 24644488708 scopus 로고    scopus 로고
    • Correlation between blood compatibility and physical surface properties of titanium-based coatings
    • Tsyganov I, Maitz MF, Wieser E, Richter E, Reuther H. Correlation between blood compatibility and physical surface properties of titanium-based coatings. Surface and Coatings Technology 200, 1041-1044 (2005).
    • (2005) Surface and Coatings Technology , vol.200 , pp. 1041-1044
    • Tsyganov, I.1    Maitz, M.F.2    Wieser, E.3    Richter, E.4    Reuther, H.5
  • 27
    • 42449145750 scopus 로고    scopus 로고
    • Stent coating with titanium-nitride-oxide for prevention of restenosis
    • Windecker S, Billinger M, Hess OM. Stent coating with titanium-nitride-oxide for prevention of restenosis. EuroInterv. 2(2), 146-148 (2006).
    • (2006) EuroInterv , vol.2 , Issue.2 , pp. 146-148
    • Windecker, S.1    Billinger, M.2    Hess, O.M.3
  • 28
    • 0035928759 scopus 로고    scopus 로고
    • Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia
    • Windecker S, Mayer I, De Pasquale G et al. Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation 104, 928-933 (2001).
    • (2001) Circulation , vol.104 , pp. 928-933
    • Windecker, S.1    Mayer, I.2    De Pasquale, G.3
  • 29
    • 0035806921 scopus 로고    scopus 로고
    • Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model
    • Suzuki T, Kopia G, Hayashi S et al. Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model. Circulation 104, 1188-1193 (2001).
    • (2001) Circulation , vol.104 , pp. 1188-1193
    • Suzuki, T.1    Kopia, G.2    Hayashi, S.3
  • 30
    • 77956467912 scopus 로고    scopus 로고
    • Comparison randomisée de lutilisation de stents couverts au titane-nitride-oxyde dans lischémie aiguë: effets sur la thrombose précoce et tardive et sur la resténose angiographique
    • Sansa M, Cernigliaro C, Rosso R et al. Comparison randomisée de lutilisation de stents couverts au titane-nitride-oxyde dans lischémie aiguë: effets sur la thrombose précoce et tardive, et sur la resténose angiographique. Archives maladies du coeur et des vaisseaux 98(12) (2005).
    • (2005) Archives Maladies du Coeur et des Vaisseaux , vol.98 , Issue.12
    • Sansa, M.1    Cernigliaro, C.2    Rosso, R.3
  • 31
    • 66449113668 scopus 로고    scopus 로고
    • Randomized comparison of percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus stainless steel stents in patients with coronary artery disease: RIO trial
    • SantAnna FM, Batista LA, Brito MB et al. Randomized comparison of percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus stainless steel stents in patients with coronary artery disease: RIO trial. Rev. Bras. Cardiol. Invas. 17(1), 69-75 (2009).
    • (2009) Rev. Bras. Cardiol. Invas , vol.17 , Issue.1 , pp. 69-75
    • Santanna, F.M.1    Batista, L.A.2    Brito, M.B.3
  • 32
    • 77956455821 scopus 로고    scopus 로고
    • Clinical outcome following PCI using titanium nitride oxide coated stents in complex patients, compared with Cypher-and Taxus-stents in a clinical registry
    • The BERN Registry. Presented at: San Francisco, CA, USA 21-25 September
    • Lauterburg A, Ltscher S, Raeber L et al. Clinical outcome following PCI using titanium nitride oxide coated stents in complex patients, compared with Cypher-and Taxus-stents in a clinical registry. The BERN Registry. Presented at: TransCatherter Therapeutics. San Francisco, CA, USA, 21-25 September (2009).
    • (2009) TransCatherter Therapeutics
    • Lauterburg, A.1    Ltscher, S.2    Raeber, L.3
  • 33
    • 77955151518 scopus 로고    scopus 로고
    • The TIBET Registry. Clinical and angiographic events in diabetes patients treated with the TITAN stent
    • Valdes M, Fernandez J, Bethencourt A et al. The TIBET Registry. Clinical and angiographic events in diabetes patients treated with the TITAN stent. Am. J. Cardiol. 94(Suppl. 6A), 47E (2004).
    • (2004) Am. J. Cardiol , vol.94 , Issue.6 SUPPL. A
    • Valdes, M.1    Fernandez, J.2    Bethencourt, A.3
  • 34
    • 77955131785 scopus 로고    scopus 로고
    • The EXTREME Registry: Titanium-nitride-oxide coated stents in small coronary arteries
    • Valdesuso R, Karjalainen P, Garcia J et al. The EXTREME Registry: Titanium-nitride-oxide coated stents in small coronary arteries. Catheter. Cardiovasc. Interv. 76(2), 281-287 (2010).
    • (2010) Catheter. Cardiovasc. Interv. , vol.76 , Issue.2 , pp. 281-287
    • Valdesuso, R.1    Karjalainen, P.2    Garcia, J.3
  • 36
    • 77956468565 scopus 로고    scopus 로고
    • Pooled analysis of trials comparing titanium-nitride-oxide-coated stents with paclitaxel-eluting stents in patients undergoing coronary stenting
    • Karjalainen PP, Biancari F, Ylitalo A et al. Pooled analysis of trials comparing titanium-nitride-oxide-coated stents with paclitaxel-eluting stents in patients undergoing coronary stenting. J. Invas. Cardiol. 22(7), 322-326 (2010).
    • (2010) J. Invas. Cardiol , vol.22 , Issue.7 , pp. 322-326
    • Karjalainen, P.P.1    Biancari, F.2    Ylitalo, A.3
  • 37
    • 24644523719 scopus 로고    scopus 로고
    • Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: Randomised Basel Stent Kosten Effektivitts Trial (BASKET)
    • Kaiser C, Brunner-La Rocca HP et al. Incremental cost-effectiveness of drug-eluting stents compared with a third-generation bare-metal stent in a real-world setting: randomised Basel Stent Kosten Effektivitts Trial (BASKET). Lancet 366(9489), 921-929 (2005).
    • (2005) Lancet , vol.366 , Issue.9489 , pp. 921-929
    • Kaiser, C.1    Brunner-La Rocca, H.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.