Internal filtration in dialyzers with different membrane permeabilities

Author keywords

Convective solute removal; Dialysis; Internal filtration

Indexed keywords

ARTICLE; ARTIFICIAL KIDNEY; BLOOD FLOWMETRY; BLOOD SAMPLING; CONTROLLED STUDY; EXPERIMENTAL STUDY; HEMOFILTRATION; INTERMETHOD COMPARISON; MEMBRANE PERMEABILITY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; ULTRAFILTRATION; WATER PERMEABILITY; ARTIFICIAL MEMBRANE; DEVICES; FILTRATION; PERMEABILITY; RENAL REPLACEMENT THERAPY;

EID: 77956465544     PISSN: 14347229     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10047-010-0506-z     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 58849138742 scopus 로고    scopus 로고
    • Validity of internal filtration-enhanced hemodialysis as a new hemodiafiltration therapy
    • Mineshima M, Ishimori I, Sakiyama R. Validity of internal filtration-enhanced hemodialysis as a new hemodiafiltration therapy. Blood Purif. 2009;27:33-7.
    • (2009) Blood Purif , vol.27 , pp. 33-37
    • Mineshima, M.1    Ishimori, I.2    Sakiyama, R.3
  • 2
    • 26844518847 scopus 로고    scopus 로고
    • Membrane fouling and dialysate flow pattern in an internal-filtration enhancing dialyzer
    • Yamamoto K, Hiwatari M, Kohori F, Sakai K, Fukuda M, Hiyoshi T. Membrane fouling and dialysate flow pattern in an internal-filtration enhancing dialyzer. J Artif Organs. 2005;8:198-205.
    • (2005) J Artif Organs , vol.8 , pp. 198-205
    • Yamamoto, K.1    Hiwatari, M.2    Kohori, F.3    Sakai, K.4    Fukuda, M.5    Hiyoshi, T.6
  • 4
    • 0030015068 scopus 로고    scopus 로고
    • Internal filtration advantage in haemodialysis?
    • Dellanna F, Wuepper A, Baldamus CA. Internal filtration advantage in haemodialysis? Nephrol Dial Transpl. 1996;11 (Suppl 2):83-6.
    • (1996) Nephrol Dial Transpl , vol.11 , Issue.SUPPL. 2 , pp. 83-86
    • Dellanna, F.1    Wuepper, A.2    Baldamus, C.A.3
  • 6
    • 0037591826 scopus 로고    scopus 로고
    • Effect of hollow fiber length on solute removal and quantification of internal filtration rate by Doppler ultrasound
    • Sato Y, Mineshima M, Ishimori I, Kaneko I, Akiba T, Teraoka S. Effect of hollow fiber length on solute removal and quantification of internal filtration rate by Doppler ultrasound. Int J Artif Organs. 2003;26:129-34.
    • (2003) Int J Artif Organs , vol.26 , pp. 129-134
    • Sato, Y.1    Mineshima, M.2    Ishimori, I.3    Kaneko, I.4    Akiba, T.5    Teraoka, S.6
  • 8
    • 0029911432 scopus 로고    scopus 로고
    • High-flux hemodialysis postpones clinical manifestation of dialysis-related amyloidosis
    • Kuchle C, Fricke H, Held E, Schiffl H. High-flux hemodialysis postpones clinical manifestation of dialysis-related amyloidosis. Am J Nephrol. 1996;16:484-8.
    • (1996) Am J Nephrol , vol.16 , pp. 484-488
    • Kuchle, C.1    Fricke, H.2    Held, E.3    Schiffl, H.4
  • 10
    • 0032947298 scopus 로고    scopus 로고
    • Comparison of mortality in ESRD patients on convective anddiffusive extracorporeal treatments
    • Locatelli F, Marcelli D, Conte F, Limido A, Malberti F, Spotti D. Comparison of mortality in ESRD patients on convective anddiffusive extracorporeal treatments. Kidney Int. 1999;55:286-93.
    • (1999) Kidney Int , vol.55 , pp. 286-93
    • Locatelli, F.1    Marcelli, D.2    Conte, F.3    Limido, A.4    Malberti, F.5    Spotti, D.6