메뉴 건너뛰기




Volumn 411, Issue 21-22, 2010, Pages 1832-

Sensitive and high sensitivity cardiac troponin I concentrations in the Heart Outcomes Prevention Evaluation (HOPE) study - A high risk population

Author keywords

[No Author keywords available]

Indexed keywords

TROPONIN I;

EID: 77956455264     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2010.07.001     Document Type: Letter
Times cited : (9)

References (5)
  • 2
    • 77956460987 scopus 로고    scopus 로고
    • High-sensitive cardiac troponin I (hs-cTnI) values in patients with stable cardiovascular disease: an initial foray
    • Schulz O., Reinicke M., Berghoefer G.H., Bensch R., Kraemer J., Schimke I., et al. High-sensitive cardiac troponin I (hs-cTnI) values in patients with stable cardiovascular disease: an initial foray. Clin. Chim. Acta 2010, 411:812-817.
    • (2010) Clin. Chim. Acta , vol.411 , pp. 812-817
    • Schulz, O.1    Reinicke, M.2    Berghoefer, G.H.3    Bensch, R.4    Kraemer, J.5    Schimke, I.6
  • 3
    • 33645300793 scopus 로고    scopus 로고
    • Troponin I as a predictor of coronary heart disease and mortality in 70-year-old men: a community-based cohort study
    • Zethelius B., Johnston N., Venge P. Troponin I as a predictor of coronary heart disease and mortality in 70-year-old men: a community-based cohort study. Circulation 2006, 113:1071-1078.
    • (2006) Circulation , vol.113 , pp. 1071-1078
    • Zethelius, B.1    Johnston, N.2    Venge, P.3
  • 4
    • 33747079319 scopus 로고    scopus 로고
    • Comparative impact of multiple biomarkers and N-terminal pro-brain natriuretic peptide in the context of conventional risk factors for the prediction of recurrent cardiovascular events in the Heart Outcomes Prevention Evaluation (HOPE) study
    • Blankenberg S., McQueen M.J., Smieja M., Pogue J., Balion C., Lonn E., et al. Comparative impact of multiple biomarkers and N-terminal pro-brain natriuretic peptide in the context of conventional risk factors for the prediction of recurrent cardiovascular events in the Heart Outcomes Prevention Evaluation (HOPE) study. Circulation 2006, 114:201-208.
    • (2006) Circulation , vol.114 , pp. 201-208
    • Blankenberg, S.1    McQueen, M.J.2    Smieja, M.3    Pogue, J.4    Balion, C.5    Lonn, E.6
  • 5
    • 62149091831 scopus 로고    scopus 로고
    • Analytic and clinical utility of a next-generation, highly sensitive cardiac troponin I assay for early detection of myocardial injury
    • Kavsak P.A., MacRae A.R., Yerna M.J., Jaffe A.S. Analytic and clinical utility of a next-generation, highly sensitive cardiac troponin I assay for early detection of myocardial injury. Clin. Chem. 2009, 55:573-577.
    • (2009) Clin. Chem. , vol.55 , pp. 573-577
    • Kavsak, P.A.1    MacRae, A.R.2    Yerna, M.J.3    Jaffe, A.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.