메뉴 건너뛰기




Volumn 33, Issue 7, 2009, Pages 525-531

A non-uniform expansion mechanical safety model of the stent

Author keywords

Displacement; Non uniform; Safety; Serial; Stent

Indexed keywords

DISPLACEMENT; LASER CUTTING; MAXIMUM DISPLACEMENT; MECHANICAL SAFETY; NON-UNIFORM; NORMAL DISPLACEMENT; SAFETY CRITERION; SAFETY LEVEL; SAFETY PROBLEMS; SERIAL; STENT; STRENGTHENING COEFFICIENT; UNSTABLE STRUCTURES;

EID: 77956409882     PISSN: 03091902     EISSN: 1464522X     Source Type: Journal    
DOI: 10.1080/07434610902744082     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 0034333737 scopus 로고    scopus 로고
    • Mechanical behaviour modeling of balloon expandable stents
    • Dumoulin, C., Cochelin, B. 2000, Mechanical behaviour modeling of balloon expandable stents. Journal of Biomechanics, 33, 1461-1470.
    • (2000) Journal of Biomechanics , vol.33 , pp. 1461-1470
    • Dumoulin, C.1    Cochelin, B.2
  • 2
    • 0034930155 scopus 로고    scopus 로고
    • Mechanical property of coronary stents determined by using finite element analysis
    • Etave, F., Finet, G., Boivin, M., Boyer, J., Rioufol, G., Thollet, G. 2001, Mechanical property of coronary stents determined by using finite element analysis. Journal of Biomechanics, 34, 1065-1075.
    • (2001) Journal of Biomechanics , vol.34 , pp. 1065-1075
    • Etave, F.1    Finet, G.2    Boivin, M.3    Boyer, J.4    Rioufol, G.5    Thollet, G.6
  • 3
    • 0036000226 scopus 로고    scopus 로고
    • Mechanical behavior of coronary stents investigated through the finite element method
    • Migliavacca, F., Petrini, L., Colombo, M., Auricchio, F. 2002, Mechanical behavior of coronary stents investigated through the finite element method. Journal of Biomechanics, 35, 803-811.
    • (2002) Journal of Biomechanics , vol.35 , pp. 803-811
    • Migliavacca, F.1    Petrini, L.2    Colombo, M.3    Auricchio, F.4
  • 4
    • 20444475661 scopus 로고    scopus 로고
    • Cardiovascular stent design and vessel stresses: A finite element analysis
    • Lally, C., Dolan, F., Prendergast, P. J. 2005, Cardiovascular stent design and vessel stresses: a finite element analysis. Journal of Biomechanics, 38, 1574-1581.
    • (2005) Journal of Biomechanics , vol.38 , pp. 1574-1581
    • Lally, C.1    Dolan, F.2    Prendergast, P.J.3
  • 5
    • 27744557004 scopus 로고    scopus 로고
    • Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method
    • Wang, W., Liang, D., Yang, D., Qi, M. 2006, Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method. Journal of Biomechanics, 39, 21-32.
    • (2006) Journal of Biomechanics , vol.39 , pp. 21-32
    • Wang, W.1    Liang, D.2    Yang, D.3    Qi, M.4
  • 7
    • 16344362656 scopus 로고    scopus 로고
    • Changes in the mechanical environment of stenotic arteries during interaction with stents: Computational assessment of parametric stent designs
    • Holzapfel, G. A. and Stadler, M. 2005, Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs. Journal of Biomechanical Engineering, 127, 166-180.
    • (2005) Journal of Biomechanical Engineering , vol.127 , pp. 166-180
    • Holzapfel, G.A.1    Stadler, M.2
  • 8
    • 34147173952 scopus 로고    scopus 로고
    • A general finite element analysis method for balloon expandable stents based on repeated unit cell (RUC) model
    • Xia, Z., Ju, F., Sasaki, K. 2007, A general finite element analysis method for balloon expandable stents based on repeated unit cell (RUC) model. Finite Elements in Analysis and Design, 43, 649-658.
    • (2007) Finite Elements in Analysis and Design , vol.43 , pp. 649-658
    • Xia, Z.1    Ju, F.2    Sasaki, K.3
  • 9
    • 25444471259 scopus 로고    scopus 로고
    • Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery
    • Liang, D., Yang, D., Qi, M., Wang, W. 2005, Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery. International Journal of Cardiology, 104, 314-318.
    • (2005) International Journal of Cardiology , vol.104 , pp. 314-318
    • Liang, D.1    Yang, D.2    Qi, M.3    Wang, W.4
  • 10
    • 32144463659 scopus 로고    scopus 로고
    • In vivo assessment of coronary artery angioplasty and stent deployment from balloon pressure-volume data
    • Olbrich, T., Williams, D. O., Doig, J. C., Murray, A. 2006, In vivo assessment of coronary artery angioplasty and stent deployment from balloon pressure-volume data. Physiological Measurement, 27, 213-223.
    • (2006) Physiological Measurement , vol.27 , pp. 213-223
    • Olbrich, T.1    Williams, D.O.2    Doig, J.C.3    Murray, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.