메뉴 건너뛰기




Volumn 48, Issue 12, 2010, Pages 1206-1212

A miniaturized carbon dioxide gas sensor based on infrared absorption

Author keywords

Carbon dioxide; Gas sensor; Infrared absorption; Measurement model; Space double beam

Indexed keywords

AIR CHAMBERS; BACKGROUND LIGHT; CARBON DIOXIDE GAS SENSOR; DIFFUSIVE SAMPLING; DOUBLE-BEAM; GAS CONCENTRATION; GAS SENSORS; INFRARED SOURCE; LAMBERT-BEER LAW; MEASUREMENT ACCURACY; MEASUREMENT MODEL; MEASUREMENT RANGE; OPTICAL PROBE; PARTIAL LEAST-SQUARES METHOD; POWER CONSUMPTION; RESPONSE TIME; SAPPHIRE WINDOWS; WORKING PRINCIPLES;

EID: 77956402493     PISSN: 01438166     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.optlaseng.2010.06.012     Document Type: Article
Times cited : (33)

References (15)
  • 3
    • 0033705156 scopus 로고    scopus 로고
    • A carbon dioxide gas sensor based on solid electrolyte for air quality control
    • K. Kaneyasu, K. Otsuka, and Y. Setoguchi A carbon dioxide gas sensor based on solid electrolyte for air quality control Sensors and Actuators B 66 2000 56 58
    • (2000) Sensors and Actuators B , vol.66 , pp. 56-58
    • Kaneyasu, K.1    Otsuka, K.2    Setoguchi, Y.3
  • 4
    • 0030108397 scopus 로고    scopus 로고
    • Phase fluorometric optical carbon dioxide gas sensor for fermentation off-gas monitoring
    • J. Sipior, L. Eichhorn, and J.R. Lakowicz Phase fluorometric optical carbon dioxide gas sensor for fermentation off-gas monitoring Biotechnol Prog 12 2 1996 266 271
    • (1996) Biotechnol Prog , vol.12 , Issue.2 , pp. 266-271
    • Sipior, J.1    Eichhorn, L.2    Lakowicz, J.R.3
  • 6
    • 49749120977 scopus 로고    scopus 로고
    • Effect of open-path gas analyzer wetness on eddy covariance flux measurements: A proposed solution
    • B.G. Heusinkveld, A.F.G. Jacobs, and A.A.M. Holtslag Effect of open-path gas analyzer wetness on eddy covariance flux measurements: a proposed solution Agricultural and Forest Meteorology 148 2008 1563 1573
    • (2008) Agricultural and Forest Meteorology , vol.148 , pp. 1563-1573
    • Heusinkveld, B.G.1    Jacobs, A.F.G.2    Holtslag, A.A.M.3
  • 8
    • 0025747804 scopus 로고
    • A fast response water vapour and carbon dioxide sensor
    • K. William A fast response water vapour and carbon dioxide sensor Proceedings of SPIE 1511 1991 114 119
    • (1991) Proceedings of SPIE , vol.1511 , pp. 114-119
    • William, K.1
  • 10
    • 2142744892 scopus 로고
    • Research of the stationary signal transitive equation and some design problems of time double beam infrared gas analyzer
    • C.Z. Zhou, and J.J. Cao Research of the stationary signal transitive equation and some design problems of time double beam infrared gas analyzer Chinese Journal of Science Instruments 3 4 1982 345 351
    • (1982) Chinese Journal of Science Instruments , vol.3 , Issue.4 , pp. 345-351
    • Zhou, C.Z.1    Cao, J.J.2
  • 12
    • 0012985055 scopus 로고    scopus 로고
    • Study of mathematical models in material corrosion prediction
    • J.W. Cheng, and Q. Zhang Study of mathematical models in material corrosion prediction Journal of Aeronautics 21 2 2000 183 186
    • (2000) Journal of Aeronautics , vol.21 , Issue.2 , pp. 183-186
    • Cheng, J.W.1    Zhang, Q.2
  • 13
    • 77956416740 scopus 로고    scopus 로고
    • Pulsable infrared light source IR-55
    • Pulsable infrared light source IR-55. In: PerkinElmer Optoelectronics, 2002.
    • (2002) PerkinElmer Optoelectronics
  • 14
    • 77956406302 scopus 로고    scopus 로고
    • Device specification for pyroelectric IR-detector
    • Device specification for pyroelectric IR-detector. In: PerkinElmer Optoelectronics, 2002.
    • (2002) PerkinElmer Optoelectronics
  • 15
    • 77956401150 scopus 로고    scopus 로고
    • Pyroelectric infrared detectors application note (Document number: AN1000.1)
    • Pyroelectric infrared detectors application note (Document number: AN1000.1). In: PerkinElmer Optoelectronics, 2002.
    • (2002) PerkinElmer Optoelectronics


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.