메뉴 건너뛰기




Volumn 62, Issue 4, 2010, Pages 250-264

Computer-assisted sleep classification according to the standard of the American Academy of sleep medicine: Validation study of the AASM version of the Somnolyzer 24 × 7

Author keywords

American Academy of Sleep Medicine standard; Arousal detection; Automated sleep scoring; Polysomnography; Semi automated sleep scoring

Indexed keywords

ADULT; AGED; ANXIETY DISORDER; ARTICLE; AUTOMATION; COMPUTER ASSISTED DIAGNOSIS; CONTROLLED STUDY; DEPRESSION; DYSKINESIA; FEMALE; HUMAN; INSOMNIA; MAJOR CLINICAL STUDY; MALE; POLYSOMNOGRAPHY; PRIORITY JOURNAL; SCORING SYSTEM; SLEEP; SLEEP APNEA SYNDROME; SLEEP DISORDER; SOMNOLENCE; VALIDATION STUDY;

EID: 77956385150     PISSN: 0302282X     EISSN: None     Source Type: Journal    
DOI: 10.1159/000320864     Document Type: Article
Times cited : (104)

References (29)
  • 2
    • 17144460085 scopus 로고
    • Automatic classification of sleep stages and the discrimination of vigilance changes using digital computer methods
    • Itil TM: Automatic classification of sleep stages and the discrimination of vigilance changes using digital computer methods. Agressologie 1969; 10(suppl):603-610.
    • (1969) Agressologie , vol.10 , Issue.SUPPL. , pp. 603-610
    • Itil, T.M.1
  • 4
    • 0021684810 scopus 로고
    • Quantitative description of sleep stage electrophysiology using digital period analytic techniques
    • Hoffmann R, Moffitt A, Wells R, Sussman P, Pigeau R, Shearer J: Quantitative description of sleep stage electrophysiology using digital period analytic techniques. Sleep 1984; 7: 356-364.
    • (1984) Sleep , vol.7 , pp. 356-364
    • Hoffmann, R.1    Moffitt, A.2    Wells, R.3    Sussman, P.4    Pigeau, R.5    Shearer, J.6
  • 5
    • 0024520653 scopus 로고
    • Sleep EEG evaluation: A comparison of results obtained by visual scoring and automatic analysis with the Oxford sleep stager
    • Kubicki S, Holler L, Berg I, Pastelak-Price C, Dorow R: Sleep EEG evaluation: a comparison of results obtained by visual scoring and automatic analysis with the Oxford sleep stager. Sleep 1989; 12:140-149.
    • (1989) Sleep , vol.12 , pp. 140-149
    • Kubicki, S.1    Holler, L.2    Berg, I.3    Pastelak-Price, C.4    Dorow, R.5
  • 6
    • 0028656445 scopus 로고
    • C STAGE, automated sleep scoring: Development and comparison with human sleep scoring for healthy older men and women
    • Prinz PN, Larsen LH, Moe KE, Dulberg EM, Vitiello MV: C STAGE, automated sleep scoring: development and comparison with human sleep scoring for healthy older men and women. Sleep 1994; 17: 711-717.
    • (1994) Sleep , vol.17 , pp. 711-717
    • Prinz, P.N.1    Larsen, L.H.2    Moe, K.E.3    Dulberg, E.M.4    Vitiello, M.V.5
  • 8
    • 0030775848 scopus 로고    scopus 로고
    • On the use of neural network techniques to analyze sleep EEG data
    • Third communication: robustification of the classificator by applying an algorithm obtained from 9 different networks
    • Baumgart-Schmitt R, Herrmann WM, Eilers R: On the use of neural network techniques to analyze sleep EEG data. Third communication: robustification of the classificator by applying an algorithm obtained from 9 different networks. Neuropsychobiology 1998; 37: 49-58.
    • (1998) Neuropsychobiology , vol.37 , pp. 49-58
    • Baumgart-Schmitt, R.1    Herrmann, W.M.2    Eilers, R.3
  • 9
    • 0035197525 scopus 로고    scopus 로고
    • Computer-assisted sleep staging
    • Agarwal R, Gotman J: Computer-assisted sleep staging. IEEE Trans Biomed Eng 2001; 48:1412-1423.
    • (2001) IEEE Trans Biomed Eng , vol.48 , pp. 1412-1423
    • Agarwal, R.1    Gotman, J.2
  • 10
    • 0036369916 scopus 로고    scopus 로고
    • Automated sleep stage detection with a classical and a neural learning algorithm-Methodological aspects
    • Pt 1
    • Schwaibold M, Schochlin J, Bolz A: Automated sleep stage detection with a classical and a neural learning algorithm-Methodological aspects. Biomed Tech (Berl) 2002; 47(suppl 1 Pt 1):318-320.
    • (2002) Biomed Tech (Berl) , vol.47 , Issue.SUPPL. 1 , pp. 318-320
    • Schwaibold, M.1    Schochlin, J.2    Bolz, A.3
  • 11
    • 16644385088 scopus 로고    scopus 로고
    • Assessment of automated scoring of polysomnographic recordings in a population with suspected sleep-disordered breathing
    • Pittman SD, MacDonald MM, Fogel RB, Malhotra A, Todros K, Levy B, Geva AB, White DP: Assessment of automated scoring of polysomnographic recordings in a population with suspected sleep-disordered breathing. Sleep 2004; 27: 1394-1403.
    • (2004) Sleep , vol.27 , pp. 1394-1403
    • Pittman, S.D.1    MacDonald, M.M.2    Fogel, R.B.3    Malhotra, A.4    Todros, K.5    Levy, B.6    Geva, A.B.7    White, D.P.8
  • 14
    • 18644375591 scopus 로고    scopus 로고
    • Sleep laboratory study on single and repeated dose effects of paroxetine, alprazolam and their combination in healthy young volunteers
    • Ba rba noj MJ, Clos S , Romero S, Morte A, Gi-ménez S, Lorenzo JL, Luque A, Dal-Ré R: Sleep laboratory study on single and repeated dose effects of paroxetine, alprazolam and their combination in healthy young volunteers. Neuropsychbiology 2005; 51: 134-147.
    • (2005) Neuropsychbiology , vol.51 , pp. 134-147
    • Barbanoj, M.J.1    Clos, S.2    Romero, S.3    Morte, A.4    Gi-Ménez, S.5    Lorenzo, J.L.6    Luque, A.7    Dal-Ré, R.8
  • 15
    • 18644373630 scopus 로고    scopus 로고
    • Insomnia in somatoform pain disorder: Sleep laboratory studies on differences to controls and acute effects of trazodone, evaluated by the Somnolyzer 24 ! 7 and the Siesta database
    • Saletu B, Prause W, Anderer P, Mandl M, Freidl M, Weiss M, Aigner M, Mikova O, Sa-letu-Zyhlarz GM: Insomnia in somatoform pain disorder: sleep laboratory studies on differences to controls and acute effects of trazodone, evaluated by the Somnolyzer 24 ! 7 and the Siesta database. Neuropsycho-biology 2005; 51: 148-163.
    • (2005) Neuropsycho-biology , vol.51 , pp. 148-163
    • Saletu, B.1    Prause, W.2    Anderer, P.3    Mandl, M.4    Freidl, M.5    Weiss, M.6    Aigner, M.7    Mikova, O.8    Sa-Letu-Zyhlarz, G.M.9
  • 16
    • 35648979000 scopus 로고    scopus 로고
    • Evaluation of automated and semi-automated scoring of poly-somnographic recordings from a clinical trial using zolpidem in the treatment of insomnia
    • Svetnik V, Ma J, Soper K, Doran S, Renger JJ, Deacon S, Koblan KS: Evaluation of automated and semi-automated scoring of poly-somnographic recordings from a clinical trial using zolpidem in the treatment of insomnia. Sleep 2007; 20:1562-1574.
    • (2007) Sleep , vol.20 , pp. 1562-1574
    • Svetnik, V.1    Ma, J.2    Soper, K.3    Doran, S.4    Renger, J.J.5    Deacon, S.6    Koblan, K.S.7
  • 26
    • 47849096398 scopus 로고    scopus 로고
    • Rethinking sleep analysis: Comment on the AASM manual for the scoring of sleep and associated events
    • Schulz H: Rethinking sleep analysis: comment on the AASM manual for the scoring of sleep and associated events. J Clin Sleep Med 2008; 4: 99-103.
    • (2008) J Clin Sleep Med , vol.4 , pp. 99-103
    • Schulz, H.1
  • 27
    • 67650753484 scopus 로고    scopus 로고
    • Commentary from the Italian Association of Sleep Medicine on the AASM manual for the scoring of sleep and associated events: For debate and discussion
    • Parrino L, Ferri R, Zucconi M, Fanfulla F: Commentary from the Italian Association of Sleep Medicine on the AASM manual for the scoring of sleep and associated events: for debate and discussion. Sleep Med 2009; 10: 799-808.
    • (2009) Sleep Med , vol.10 , pp. 799-808
    • Parrino, L.1    Ferri, R.2    Zucconi, M.3    Fanfulla, F.4
  • 28
    • 43749102945 scopus 로고    scopus 로고
    • Insufficient evidence for the use of automated and semi-automated scoring of polysomnographic recordings
    • Zammit GK: Insufficient evidence for the use of automated and semi-automated scoring of polysomnographic recordings. Sleep 2008; 31:449-450
    • (2008) Sleep , vol.31 , pp. 449-450
    • Zammit, G.K.1
  • 29
    • 43749110948 scopus 로고    scopus 로고
    • Automated sleep scoring with human supervision adds value compared with human scoring alone: A reply to Zammit GK: Insufficient evidence for the use of automated and semi-automated scoring of polysomnographic recordings
    • 451
    • Svetnik V, Ma J, Soper K, Doran S, Renger JJ, Deacon S, Koblan KS: Automated sleep scoring with human supervision adds value compared with human scoring alone: a reply to Zammit GK: Insufficient evidence for the use of automated and semi-automated scoring of polysomnographic recordings. Sleep 2008; 31:449-450, 451.
    • (2008) Sleep , vol.31 , pp. 449-450
    • Svetnik, V.1    Ma, J.2    Soper, K.3    Doran, S.4    Renger, J.J.5    Deacon, S.6    Koblan, K.S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.