메뉴 건너뛰기




Volumn 92, Issue 9, 2010, Pages 1231-1237

Mid-term results of a custom-made short proximal loading femoral component

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT; HYDROXYAPATITE; POLYETHYLENE;

EID: 77956364263     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.92B9.24605     Document Type: Article
Times cited : (93)

References (33)
  • 1
    • 0023759917 scopus 로고
    • Design and fabrication of cementless hip stems
    • Walker PS, Robertson DD. Design and fabrication of cementless hip stems. Clin Orthop 1988;235:25-34.
    • (1988) Clin Orthop , vol.235 , pp. 25-34
    • Walker, P.S.1    Robertson, D.D.2
  • 2
    • 0028500510 scopus 로고
    • Fit of the uncemented femoral component and the use of cement influence the strain transfer to the femoral cortex
    • DOI 10.1002/jor.1100120507
    • Jasty M, O'Connor DO, Henshaw RM, Harrigan TP, Harris WH. Fit of the uncemented femoral component and the use of cement influence the strain transfer to the femoral cortex. J Orthop Res 1994;12:648-56. (Pubitemid 24323687)
    • (1994) Journal of Orthopaedic Research , vol.12 , Issue.5 , pp. 648-656
    • Jasty, M.1    O'Connor, D.O.2    Henshaw, R.M.3    Harrigan, T.P.4    Harris, W.H.5
  • 3
    • 2942716988 scopus 로고    scopus 로고
    • Seven to 10 years followup of an anatomic hip prosthesis: An international study
    • Herrera A, Canales V, Anderson J, et al. Seven to 10 years followup of an anatomic hip prosthesis: an international study. Clin Orthop 2004;423:129-37.
    • (2004) Clin Orthop , vol.423 , pp. 129-137
    • Herrera, A.1    Canales, V.2    Anderson, J.3
  • 4
    • 0036833958 scopus 로고    scopus 로고
    • Thigh pain after cementless total hip arthroplasty: Evaluation and management
    • Brown TE, Larson B, Shen F, Moskal JT. Thigh pain after cementless total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg 2002;10:385-92.
    • (2002) J Am Acad Orthop Surg , vol.10 , pp. 385-392
    • Brown, T.E.1    Larson, B.2    Shen, F.3    Moskal, J.T.4
  • 5
    • 0029012465 scopus 로고
    • Closeness of fit of uncemented stems improves the strain distribution in the femur
    • Hua J, Walker PS. Closeness of fit of uncemented stems improves the strain distribution in the femur. J Orthop Res 1995;13:339-46.
    • (1995) J Orthop Res , vol.13 , pp. 339-346
    • Hua, J.1    Walker, P.S.2
  • 6
    • 0028788095 scopus 로고
    • Effect of neck resection on torsional stability of cementless total hip replacement
    • Whiteside LA, White SE, McCarthy DS. Effect of neck resection on torsional stability of cementless total hip replacement. Am J Orthop 1995;24:766-70.
    • (1995) Am J Orthop , vol.24 , pp. 766-770
    • Whiteside, L.A.1    White, S.E.2    McCarthy, D.S.3
  • 9
    • 0019943719 scopus 로고
    • The direct lateral approach to the hip
    • Hardinge K. The direct lateral approach to the hip. J Bone Joint Surg [Br] 1982;64-B:17-19.
    • (1982) J Bone Joint Surg [Br] , vol.64 B , pp. 17-19
    • Hardinge, K.1
  • 10
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: an end-result study using a new method of result evaluation
    • Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg [Am] 1969;51-A:737-55.
    • (1969) J Bone Joint Surg [Am] , vol.51 A , pp. 737-755
    • Harris, W.H.1
  • 11
    • 0024268463 scopus 로고
    • Validation study of WOMAC: A health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee
    • Bellamy N, Buchanan WW, Goldsmith CH. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 1988;15:1833-40.
    • (1988) J Rheumatol , vol.15 , pp. 1833-1840
    • Bellamy, N.1    Buchanan, W.W.2    Goldsmith, C.H.3
  • 12
    • 2642570359 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with a proximally porous-coated femoral stem
    • Sinha RK, Dungy DS, Yeon HB. Primary total hip arthroplasty with a proximally porous-coated femoral stem. J Bone Joint Surg [Am] 2004;86-A:1254-61.
    • (2004) J Bone Joint Surg [Am] , vol.86 A , pp. 1254-1261
    • Sinha, R.K.1    Dungy, D.S.2    Yeon, H.B.3
  • 13
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 1990;257:107-28. (Pubitemid 20246731)
    • (1990) Clinical Orthopaedics and Related Research , Issue.257 , pp. 107-128
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 14
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17-27.
    • (1979) Clin Orthop , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 15
    • 0029842374 scopus 로고    scopus 로고
    • A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: Radiographic evaluation and stability
    • Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability. J Bone Joint Surg [Am] 1996;78-A:1214-25. (Pubitemid 26284896)
    • (1996) Journal of Bone and Joint Surgery - Series a , vol.78 , Issue.8 , pp. 1214-1225
    • Mulliken, B.D.1    Bourne, R.B.2    Rorabeck, C.H.3    Nayak, N.4
  • 16
    • 0031718704 scopus 로고    scopus 로고
    • Intraoperative type 1 proximal femoral fractures: Influence on the stability of hydroxyapatite-coated femoral components
    • DOI 10.1016/S0883-5403(98)80009-0
    • Falez F, Santori N, Panegrossi G. Intraoperative type 1 proximal femoral fractures: influence on the study of hydroxyapatite-coated femoral components. J Arthroplasty 1998;13:653-9. (Pubitemid 28413594)
    • (1998) Journal of Arthroplasty , vol.13 , Issue.6 , pp. 653-659
    • Falez, F.1    Santori, N.2    Panegrossi, G.3
  • 17
    • 0028117917 scopus 로고
    • Reliability and validity of the grading of heterotopic ossification
    • DOI 10.1016/0883-5403(94)90104-X
    • Wright JG, Moran E, Bogoch E. Reliability and validity of the grading of heterotopic ossification. J Arthroplasty 1994;9:549-53. (Pubitemid 24321145)
    • (1994) Journal of Arthroplasty , vol.9 , Issue.5 , pp. 549-553
    • Wright, J.G.1    Moran, E.2    Bogoch, E.3
  • 18
    • 0029120273 scopus 로고
    • Re-examination of hip biomechanics during unilateral stance
    • Fetto JF, Bettinger P, Austin KS. Re-examination of hip biomechanics during unilateral stance. Am J Orthop 1995;8:60-5-12.
    • (1995) Am J Orthop , vol.8
    • Fetto, J.F.1    Bettinger, P.2    Austin, K.S.3
  • 19
    • 38349035572 scopus 로고
    • Variable geometry for proximal femoral fixation
    • Coombs R, Gristina A, Hungerford D, eds. London: Orthotext
    • Gallinaro P, Massè G, Elloy M, Isaac G, Cohen A. Variable geometry for proximal femoral fixation. In: Coombs R, Gristina A, Hungerford D, eds. Joint replacement: state of the art. London: Orthotext, 1990:113-16.
    • (1990) Joint Replacement: State of the Art , pp. 113-116
    • Gallinaro, P.1    Massè, G.2    Elloy, M.3    Isaac, G.4    Cohen, A.5
  • 21
    • 0032785232 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with a cementless porouscoated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series
    • Kim YH, Kim JS, Cho SH. Primary total hip arthroplasty with a cementless porouscoated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J Arthroplasty 1999;14:538-48.
    • (1999) J Arthroplasty , vol.14 , pp. 538-548
    • Kim, Y.H.1    Kim, J.S.2    Cho, S.H.3
  • 22
    • 0027256183 scopus 로고
    • The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components
    • Jasty M, Krushell R, Zalenski E, et al. The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components. J Arthroplasty 1993;8:33-41. (Pubitemid 23128436)
    • (1993) Journal of Arthroplasty , vol.8 , Issue.1 , pp. 33-41
    • Jasty, M.1    Krushell, R.2    Zalenski, E.3    O'Connor, D.4    Sedlacek, R.5    Harris, W.6
  • 23
    • 33744965007 scopus 로고    scopus 로고
    • Ultra-short stems with proximal load transfer: Clinical and radiographic results at five-year follow-up
    • Santori FS, Manili M, Fredella N, Tonci Ottieri M, Santori N. Ultra short stems with proximal load transfer: clinical and radiographic results at five year follow-up. Hip Int 2006;16(Suppl 3):31-9. (Pubitemid 43853557)
    • (2006) HIP International , vol.16 , Issue.SUPPL. 3
    • Santori, F.S.1    Manili, M.2    Fredella, N.3    Tonci Ottieri, M.4    Santori, N.5
  • 24
    • 0035216878 scopus 로고    scopus 로고
    • Load transfer and stress shielding of the hydroxyapatite-ABG hip: A study of stem length and proximal fixation
    • DOI 10.1054/arth.2001.28369
    • van Rietbergen B, Huiskes R. Load transfer and stress shielding of the hydroxyapatite-ABG hip: a study of stem length and proximal fixation. J Arthroplasty 2001;16(Suppl 1):55-63. (Pubitemid 33151048)
    • (2001) Journal of Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 55-63
    • Van Rietbergen, B.1    Huiskes, R.2
  • 25
    • 74249089252 scopus 로고    scopus 로고
    • Periprosthetic DXA after total hip arthroplasty with short vs ultrashort custom made femoral stems: 37 patients followed for 3 yrs
    • Albanese VA, Santori FS, Pavan L, Learmonth ID, Passariello R. Periprosthetic DXA after total hip arthroplasty with short vs ultrashort custom made femoral stems: 37 patients followed for 3 yrs. Acta Orthop 2009;1:291-7.
    • (2009) Acta Orthop , vol.1 , pp. 291-297
    • Albanese, V.A.1    Santori, F.S.2    Pavan, L.3    Learmonth, I.D.4    Passariello, R.5
  • 26
    • 2642516293 scopus 로고    scopus 로고
    • The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: A 10-year, prospective, randomized study
    • DOI 10.1016/j.arth.2003.12.081, PII S0883540304000968
    • Karachalios T, Tsatsaronis C, Efraimis G, et al. The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study. J Arthroplasty 2004;19:469-75. (Pubitemid 38725930)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.4 , pp. 469-475
    • Karachalios, T.1    Tsatsaronis, C.2    Efraimis, G.3    Papadelis, P.4    Lyritis, G.5    Diakoumopoulos, G.6
  • 27
    • 33744979310 scopus 로고    scopus 로고
    • Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems
    • DOI 10.1016/j.clinbiomech.2005.12.011, PII S0268003305003104
    • Decking R, Puhl W, Simon U, Claes LE. Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems. Clin Biomech 2006;21:495-501. (Pubitemid 44389484)
    • (2006) Clinical Biomechanics , vol.21 , Issue.5 , pp. 495-501
    • Decking, R.1    Puhl, W.2    Simon, U.3    Claes, L.E.4
  • 30
    • 65649132269 scopus 로고    scopus 로고
    • An in vitro study of the strain distribution in human femora with anatomical and customised femoral stems
    • Østbyhaug PO, Klaksvik J, Romundstad P, Aamodt A. An in vitro study of the strain distribution in human femora with anatomical and customised femoral stems. J Bone Joint Surg [Br] 2009;91-B:676-82.
    • (2009) J Bone Joint Surg [Br] , vol.91 B , pp. 676-682
    • Østbyhaug, P.O.1    Klaksvik, J.2    Romundstad, P.3    Aamodt, A.4
  • 31
    • 0026560894 scopus 로고
    • Determinants of stress shielding: Design versus materials versus interface
    • Sumner DR, Galante JO. Determinants of stress shielding: design versus materials versus interface. Clin Orthop 1992;274:202-12.
    • (1992) Clin Orthop , vol.274 , pp. 202-212
    • Sumner, D.R.1    Galante, J.O.2
  • 33
    • 68649089531 scopus 로고    scopus 로고
    • Bone remodelling characteristics of a short-stemmed total hip replacement
    • Chen HH, Morrey BF, An KN, Luo ZP. Bone remodelling characteristics of a short-stemmed total hip replacement. J Arthroplasty 2009;24:945-50.
    • (2009) J Arthroplasty , vol.24 , pp. 945-950
    • Chen, H.H.1    Morrey, B.F.2    An, K.N.3    Luo, Z.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.