메뉴 건너뛰기




Volumn 33, Issue 9, 2010, Pages 1149-1152

An anatomic-based approach for the placement of implantable loop recorders

Author keywords

biomedical engineering; loop recorders; pacing

Indexed keywords

ACTION POTENTIAL; ADULT; ARTICLE; ELECTROCARDIOGRAPHY; FEMALE; FOLLOW UP; FUNCTIONAL ANATOMY; HUMAN; IMPLANT; IMPLANTABLE LOOP RECORDER; MAJOR CLINICAL STUDY; MALE; PREOPERATIVE CARE; QRS COMPLEX; SYNCOPE; THORAX;

EID: 77956330482     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2010.02747.x     Document Type: Article
Times cited : (23)

References (10)
  • 1
    • 0032943618 scopus 로고    scopus 로고
    • Use of an extended monitoring strategy in patients with problematic syncope
    • Krahn AD, Klein GJ, Yee R, Takle-Newhouse T, Norris C. Use of an extended monitoring strategy in patients with problematic syncope. Circulation 1999 99 : 406 410.
    • (1999) Circulation , vol.99 , pp. 406-410
    • Krahn, A.D.1    Klein, G.J.2    Yee, R.3    Takle-Newhouse, T.4    Norris, C.5
  • 2
    • 41249101681 scopus 로고    scopus 로고
    • Analysing the potential of Reveal for monitoring cardiac potentials
    • van Dam PM, van Oosterom A. Analysing the potential of Reveal for monitoring cardiac potentials. Europace 2007 9 (Suppl 6 vi119 123.
    • (2007) Europace , vol.9 , Issue.SUPPL. 6 , pp. 119-123
    • Van Dam, P.M.1    Van Oosterom, A.2
  • 5
    • 1842865766 scopus 로고    scopus 로고
    • Feasibility of the inframammary location for insertable loop recorders in young women and girls
    • Kannankeril PJ, Bibeau DA, Fish FA. Feasibility of the inframammary location for insertable loop recorders in young women and girls. Pacing Clin Electrophysiol 2004 27 : 492 494.
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 492-494
    • Kannankeril, P.J.1    Bibeau, D.A.2    Fish, F.A.3
  • 8
    • 0035654566 scopus 로고    scopus 로고
    • Initial clinical experience with implantable loop recorders
    • Mieszczanska H, Ibrahim B, Cohen TJ. Initial clinical experience with implantable loop recorders. J Invasive Cardiol 2001 13 : 802 804.
    • (2001) J Invasive Cardiol , vol.13 , pp. 802-804
    • Mieszczanska, H.1    Ibrahim, B.2    Cohen, T.J.3
  • 9
    • 0034232371 scopus 로고    scopus 로고
    • Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder. Reveal-Investigators
    • Reveal-Investigators.
    • Seidl K, Rameken M, Breunung S, Senges J, Jung W, Andresen D, van Toor A, et al Reveal-Investigators. Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder. Reveal-Investigators. Europace 2000 2 : 256 262.
    • (2000) Europace , vol.2 , pp. 256-262
    • Seidl, K.1    Rameken, M.2    Breunung, S.3    Senges, J.4    Jung, W.5    Andresen, D.6    Van Toor, A.7
  • 10
    • 70350059322 scopus 로고    scopus 로고
    • Improving sensing and detection performance in subcutaneous monitors
    • Aug 7. [Epub ahead of print].
    • van Dam P, van Groeningen C, Houben RP, Hampton DR. Improving sensing and detection performance in subcutaneous monitors. J Electrocardiol 2009 Aug 7. [Epub ahead of print].
    • (2009) J Electrocardiol
    • Van Dam, P.1    Van Groeningen, C.2    Houben, R.P.3    Hampton, D.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.