Enhancement of in-plane spatial resolution in volumetric computed tomography with focal spot wobbling - Overcoming the constraint on number of projection views per gantry rotation

Author keywords

3D reconstruction; Cone beam volume CT; CT reconstruction; focal spot wobbling; Reconstruction algorithms

Indexed keywords

3D RECONSTRUCTION; CONE-BEAM VOLUME CT; CT RECONSTRUCTION; FOCAL SPOT; RECONSTRUCTION ALGORITHMS;

EID: 77956316715     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: 10.3233/XST-2010-0258     Document Type: Article
Times cited : (29)

References (17)
  • 4
    • 23944513257 scopus 로고    scopus 로고
    • Image reconstruction and image quality evaluation for a 64slice CT scanner with zflying focal spot
    • T.G. Flohr, K. Stierstorfer, S. Ulzheimer, H. Bruder, A.N. Primak and C.H.McColough, Image reconstruction and image quality evaluation for a 64slice CT scanner with zflying focal spot, Med Phys 32 (2005), 2536-2547.
    • (2005) Med Phys , vol.32 , pp. 2536-2547
    • Flohr, T.G.1    Stierstorfer, K.2    Ulzheimer, S.3    Bruder, H.4    Primak, A.N.5    McColough, C.H.6
  • 7
    • 0033983855 scopus 로고    scopus 로고
    • An iterative approach to the beam hardening correction in cone beam CT
    • J. Hsieh, An iterative approach to the beam hardening correction in cone beam CT, Med Phys 27 (2000), 23-29.
    • (2000) Med Phys , vol.27 , pp. 23-29
    • Hsieh, J.1
  • 10
    • 0034982804 scopus 로고    scopus 로고
    • Angular weighted hybrid conebeam CT reconstruction for circular trajectories
    • M. Grass, T. Khler and R. Proksa, Angular weighted hybrid conebeam CT reconstruction for circular trajectories, Phys Med Biol 46 (2001), 1595-1610.
    • (2001) Phys Med Biol , vol.46 , pp. 1595-1610
    • Grass, M.1    Khler, T.2    Proksa, R.3
  • 11
    • 0034764254 scopus 로고    scopus 로고
    • Rebinningbased algorithms for helical conebeam CT
    • M. Defrise, F. Noo and H. Kudo, Rebinningbased algorithms for helical conebeam CT, Phys Med Biol 46 (2001), 2911-2937.
    • (2001) Phys Med Biol , vol.46 , pp. 2911-2937
    • Defrise, M.1    Noo, F.2    Kudo, H.3
  • 12
    • 23744435329 scopus 로고    scopus 로고
    • A threedimensional weighted cone beam filtered backprojection (CBFBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory
    • X. Tang, J. Hsieh, R.A. Nilsen, A. Hagiwara, J. Thibault and E. Drapkin, A threedimensional weighted cone beam filtered backprojection (CBFBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory, Phys Med Biol (2005), 3889-3905.
    • (2005) Phys Med Biol , pp. 3889-3905
    • Tang, X.1    Hsieh, J.2    Nilsen, R.A.3    Hagiwara, A.4    Thibault, J.5    Drapkin, E.6
  • 13
    • 33645511679 scopus 로고    scopus 로고
    • A threedimensional weighted cone beam filtered backprojection (CBFBP) algorithm for image reconstruction in volumetric CT - Helical scanning
    • X. Tang, J. Hsieh, R.A. Nilsen, S. Dutta, D. Samsonov and A. Hagiwara, A threedimensional weighted cone beam filtered backprojection (CBFBP) algorithm for image reconstruction in volumetric CT - Helical scanning, Phys Med Biol 51 (2006), 855-874.
    • (2006) Phys Med Biol , vol.51 , pp. 855-874
    • Tang, X.1    Hsieh, J.2    Nilsen, R.A.3    Dutta, S.4    Samsonov, D.5    Hagiwara, A.6
  • 14
    • 77956311510 scopus 로고    scopus 로고
    • Accessed on Oct.
    • http://www.phantomlab.com/pdf/catphan500600manual. pdf. Accessed on Oct. 1, 2009.
    • (2009) , vol.1
  • 15
  • 16
    • 0018733995 scopus 로고
    • Detectability in computed tomography images
    • K.M. Hanson, Detectability in computed tomography images, Phys Med Biol 6 (1979), 441-451.
    • (1979) Phys Med Biol , vol.6 , pp. 441-451
    • Hanson, K.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.