메뉴 건너뛰기




Volumn 6, Issue 4, 2010, Pages 349-356

The role of single-channel nasal airflow pressure transducer in the diagnosis of OSA in the sleep laboratory

Author keywords

Diagnosis; Obstructive sleep apnea; Pressure transducer; Single channel device; Women

Indexed keywords

AREA UNDER THE CURVE; ARTICLE; CLINICAL TRIAL; CONFIDENCE INTERVAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; NOSE AIRFLOW; POLYSOMNOGRAPHY; PRESSURE TRANSDUCER; SLEEP APNEA SYNDROME;

EID: 77956271568     PISSN: 15509389     EISSN: 15509397     Source Type: Journal    
DOI: 10.5664/jcsm.27876     Document Type: Article
Times cited : (15)

References (27)
  • 1
    • 0036569980 scopus 로고    scopus 로고
    • Epidemiology of obstructive sleep apnea - A population health perspective
    • Young T, Peppard PE, Gottlieb DJ. Epidemiology of obstructive sleep apnea - A population health perspective. Am J Respir Crit Care Med 2002;165:1217-39.
    • (2002) Am J Respir Crit Care Med , vol.165 , pp. 1217-1239
    • Young, T.1    Peppard, P.E.2    Gottlieb, D.J.3
  • 2
    • 0028456969 scopus 로고
    • Portable recording in the assessment of obstructive sleep-apnea
    • Ferber R, Millman R, Coppola M, et al. Portable recording in the assessment of obstructive sleep-apnea. Sleep 1994;17:378-92.
    • (1994) Sleep , vol.17 , pp. 378-392
    • Ferber, R.1    Millman, R.2    Coppola, M.3
  • 3
    • 38849206434 scopus 로고    scopus 로고
    • Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients
    • Portable Monitoring Task Force of the American Academy of Sleep Medicine
    • Collop NA, Anderson WM, Boehlecke B, et al. Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med 2007;3:737-47.
    • (2007) J Clin Sleep Med , vol.3 , pp. 737-747
    • Collop, N.A.1    Anderson, W.M.2    Boehlecke, B.3
  • 4
    • 0031939916 scopus 로고    scopus 로고
    • Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas
    • Farre R, Montserrat JM, Rotger M, et al. Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas. Eur Respir J 1998;11:179-82.
    • (1998) Eur Respir J , vol.11 , pp. 179-182
    • Farre, R.1    Montserrat, J.M.2    Rotger, M.3
  • 5
    • 0036007248 scopus 로고    scopus 로고
    • The SleepStrip (TM): An apnoea screener for the early detection of sleep apnoea syndrome
    • Shochat T, Hadas N, Kerkhofs M, et al. The SleepStrip (TM): an apnoea screener for the early detection of sleep apnoea syndrome. Eur Respir J 2002;19:121-6.
    • (2002) Eur Respir J , vol.19 , pp. 121-126
    • Shochat, T.1    Hadas, N.2    Kerkhofs, M.3
  • 6
    • 0037677750 scopus 로고    scopus 로고
    • Practicality of the Sleepstrip (TM) in postal screening for obstructive sleep apnoea
    • DOI 10.1046/j.1365-2869.2003.00349.x
    • Hollingworth L, Tooby M, Roberts D, et al. Practicality of the Sleepstrip (TM) in postal screening for obstructive sleep apnoea. J Sleep Res 2003;12:157-9. (Pubitemid 36628373)
    • (2003) Journal of Sleep Research , vol.12 , Issue.2 , pp. 157-159
    • Hollingworth, L.1    Tooby, M.2    Roberts, D.3    Hanning, C.D.4
  • 7
    • 33746574527 scopus 로고    scopus 로고
    • A comparison of polysomnography and the SleepStrip in the diagnosis of OSA
    • Pang KP, Gourin CG, Podolsky R, et al. A comparison of polysomnography and the SleepStrip in the diagnosis of OSA. Otolaryngol Head Neck Surg 2006;135:265-8.
    • (2006) Otolaryngol Head Neck Surg , vol.135 , pp. 265-268
    • Pang, K.P.1    Gourin, C.G.2    Podolsky, R.3
  • 8
    • 34147169517 scopus 로고    scopus 로고
    • Automatic detection of sleep-disordered breathing from a single-channel airflow record
    • DOI 10.1183/09031936.00091206
    • Nakano H, Tanigawao T, Furukawa T, et al. Automatic detection of sleep-disordered breathing from a single-channel airflow record. Eur Respir J 2007;29:728-36. (Pubitemid 46554623)
    • (2007) European Respiratory Journal , vol.29 , Issue.4 , pp. 728-736
    • Nakano, H.1    Tanigawa, T.2    Furukawa, T.3    Nishima, S.4
  • 9
    • 58849098679 scopus 로고    scopus 로고
    • Validation of a single-channel airflow monitor for screening of sleep-disordered breathing
    • Nakano H, Tanigawa T, Ohnishi Y, et al. Validation of a single-channel airflow monitor for screening of sleep-disordered breathing. Eur Respir J 2008;32:1060-7.
    • (2008) Eur Respir J , vol.32 , pp. 1060-1067
    • Nakano, H.1    Tanigawa, T.2    Ohnishi, Y.3
  • 10
    • 0033178851 scopus 로고    scopus 로고
    • Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research
    • American Academy of Sleep Medicine Task Force
    • American Academy of Sleep Medicine Task Force. Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research. Sleep 1999;22:667-89.
    • (1999) Sleep , vol.22 , pp. 667-689
  • 11
    • 0036682889 scopus 로고    scopus 로고
    • Validation of nasal pressure for the identification of apneas/hypopneas during sleep
    • Heitman SJ, Atkar RS, Hajduk EA, et al. Validation of nasal pressure for the identification of apneas/hypopneas during sleep. Am J Respir Crit Care Med 2002;166:386-91.
    • (2002) Am J Respir Crit Care Med , vol.166 , pp. 386-391
    • Heitman, S.J.1    Atkar, R.S.2    Hajduk, E.A.3
  • 12
    • 34250800983 scopus 로고    scopus 로고
    • Validation of the ApneaLink for the screening of sleep apnea: A novel and simple single-channel recording device
    • Erman MK, Stewart D, Einhorn D, et al. Validation of the ApneaLink for the screening of sleep apnea: a novel and simple single-channel recording device. J Clin Sleep Med 2007;3:387-92.
    • (2007) J Clin Sleep Med , vol.3 , pp. 387-392
    • Erman, M.K.1    Stewart, D.2    Einhorn, D.3
  • 13
    • 43249124214 scopus 로고    scopus 로고
    • Diagnostic test evaluation of a nasal flow monitor for obstructive sleep apnea detection in sleep apnea research
    • Wong KKH, Jankelson D, Reid A, et al. Diagnostic test evaluation of a nasal flow monitor for obstructive sleep apnea detection in sleep apnea research. Behav Res Methods 2008;40:360-6.
    • (2008) Behav Res Methods , vol.40 , pp. 360-366
    • Wong, K.K.H.1    Jankelson, D.2    Reid, A.3
  • 14
    • 33746899689 scopus 로고    scopus 로고
    • Nasal pressure recordings to detect obstructive sleep apnea
    • De Almeida F, Ayas N, Otsuka R, et al. Nasal pressure recordings to detect obstructive sleep apnea. Sleep Breath 2006:1-8.
    • (2006) Sleep Breath , pp. 1-8
    • De Almeida, F.1    Ayas, N.2    Otsuka, R.3
  • 15
    • 33750369320 scopus 로고    scopus 로고
    • Gender differences in sleep disorders
    • Krishnan V, Collop NA. Gender differences in sleep disorders. Curr Opin Pulm Med 2006;12:383-9.
    • (2006) Curr Opin Pulm Med , vol.12 , pp. 383-389
    • Krishnan, V.1    Collop, N.A.2
  • 16
    • 55749089871 scopus 로고    scopus 로고
    • Gender differences in obstructive sleep apnea and treatment implications
    • Lin CM, Davidson TM, Ancoli-Israel S. Gender differences in obstructive sleep apnea and treatment implications. Sleep Med Rev 2008;12.481-96.
    • (2008) Sleep Med Rev , vol.12 , pp. 481-496
    • Lin, C.M.1    Davidson, T.M.2    Ancoli-Israel, S.3
  • 17
    • 1942476580 scopus 로고    scopus 로고
    • Gender differences in sleep and sleep-disordered breathing
    • DOI 10.1016/j.ccm.2004.01.002, PII S0272523104000164
    • Collop NA, Adkins D, Phillips BA. Gender differences in sleep and sleep-disordered breathing. Clin Chest Med 2004;25:257-68. (Pubitemid 38507646)
    • (2004) Clinics in Chest Medicine , vol.25 , Issue.2 , pp. 257-268
    • Collop, N.A.1    Adkins, D.2    Phillips, B.A.3
  • 18
    • 0027462562 scopus 로고
    • The occurrence of sleep-disordered breathing among middle-aged adults
    • Young T, Palta M, Dempsey J, et al. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med 1993;328:1230-5.
    • (1993) N Engl J Med , vol.328 , pp. 1230-1235
    • Young, T.1    Palta, M.2    Dempsey, J.3
  • 20
    • 0026333617 scopus 로고
    • A new method for measuring daytime sleepiness - The Epworth Sleepiness Scale
    • Johns MW. A new method for measuring daytime sleepiness - the Epworth Sleepiness Scale. Sleep 1991;14:540-5.
    • (1991) Sleep , vol.14 , pp. 540-545
    • Johns, M.W.1
  • 21
    • 0028900185 scopus 로고
    • A survey screen for prediction of apnea
    • Maislin G, Pack AI, Kribbs NB, et al. A survey screen for prediction of apnea. Sleep 1995;18:158-66.
    • (1995) Sleep , vol.18 , pp. 158-166
    • Maislin, G.1    Pack, A.I.2    Kribbs, N.B.3
  • 22
    • 0033527361 scopus 로고    scopus 로고
    • Using the Berlin Questionnaire to identify patients at risk for the sleep apnea syndrome
    • Netzer NC, Stoohs RA, Netzer CM, et al. Using the Berlin Questionnaire to identify patients at risk for the sleep apnea syndrome. Ann Intern Med 1999;131:485-91.
    • (1999) Ann Intern Med , vol.131 , pp. 485-491
    • Netzer, N.C.1    Stoohs, R.A.2    Netzer, C.M.3
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 25
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983;148:839-43.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 26
    • 0033825836 scopus 로고    scopus 로고
    • Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome
    • Portier F, Portmann A, Czernichow P, et al. Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome. Am J Respir Crit Care Med 2000;162:814-8.
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 814-818
    • Portier, F.1    Portmann, A.2    Czernichow, P.3
  • 27
    • 53549116451 scopus 로고    scopus 로고
    • Automated detection of sleep disordered breathing using a nasal pressure monitoring device
    • Grover SS, Pittman SD. Automated detection of sleep disordered breathing using a nasal pressure monitoring device. Sleep Breath 2008;12:339-45.
    • (2008) Sleep Breath , vol.12 , pp. 339-345
    • Grover, S.S.1    Pittman, S.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.