메뉴 건너뛰기




Volumn 163, Issue 1-2, 2010, Pages 160-163

A novel bioelectro-Fenton system for coupling anodic COD removal with cathodic dye degradation

Author keywords

Bioelectro Fenton process; COD removal; Hydrogen peroxide; Microbial fuel cell; Rhodamine B

Indexed keywords

CARBON FELTS; CATHODIC CURRENT DENSITY; COD REMOVAL; COMPOSITE CATHODE; DYE DEGRADATION; ELECTRO-FENTON PROCESS; FENTON PROCESS; FENTON SYSTEM; FENTON'S REACTION; HYDROXYL RADICALS; PERSISTENT ORGANIC POLLUTANTS; RHODAMINE B; SHORT-CIRCUIT CONDITIONS; TOC REMOVAL;

EID: 77956268257     PISSN: 13858947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cej.2010.07.039     Document Type: Article
Times cited : (115)

References (19)
  • 1
    • 0000009222 scopus 로고
    • Hydoxylation by electrochemically generated OH radicals. Mono and polyhydroxylation of benzoic acid: products and isomers distribution
    • Oturan M.A., Pinson J. Hydoxylation by electrochemically generated OH radicals. Mono and polyhydroxylation of benzoic acid: products and isomers distribution. J. Phys. Chem. 1995, 99:13948-13954.
    • (1995) J. Phys. Chem. , vol.99 , pp. 13948-13954
    • Oturan, M.A.1    Pinson, J.2
  • 2
    • 22544486024 scopus 로고    scopus 로고
    • Degradation of three pesticides used in viticulture by electrogenerated Fenton's reagent
    • Oturan N., Oturan M.A. Degradation of three pesticides used in viticulture by electrogenerated Fenton's reagent. Agron. Sustain. Dev. 2005, 25:267-270.
    • (2005) Agron. Sustain. Dev. , vol.25 , pp. 267-270
    • Oturan, N.1    Oturan, M.A.2
  • 3
    • 0033741826 scopus 로고    scopus 로고
    • An ecologically effective water treatment technique using electrochemically generated hydroxyl radicals for in situ destruction of organic pollutants: application to herbicide 2, 4-D
    • Oturan M.A. An ecologically effective water treatment technique using electrochemically generated hydroxyl radicals for in situ destruction of organic pollutants: application to herbicide 2, 4-D. J. Appl. Electrochem. 2000, 30:475-482.
    • (2000) J. Appl. Electrochem. , vol.30 , pp. 475-482
    • Oturan, M.A.1
  • 4
    • 0032022034 scopus 로고    scopus 로고
    • Degradation of 4-chlorophenol by anodic oxidation, electro-Fenton, photoelectro-Fenton and peroxi-coagulation processes
    • Brillas E., Sauleda R., Casado J. Degradation of 4-chlorophenol by anodic oxidation, electro-Fenton, photoelectro-Fenton and peroxi-coagulation processes. J. Electrochem. Soc. 1998, 145:759-765.
    • (1998) J. Electrochem. Soc. , vol.145 , pp. 759-765
    • Brillas, E.1    Sauleda, R.2    Casado, J.3
  • 5
    • 0033121079 scopus 로고    scopus 로고
    • Degradation of selected pesticide active ingredients and commercial formulations in water by the photo-assisted Fenton reaction
    • Huston P.L., Pignatello J.J. Degradation of selected pesticide active ingredients and commercial formulations in water by the photo-assisted Fenton reaction. Water Res. 1999, 33:1238-1246.
    • (1999) Water Res. , vol.33 , pp. 1238-1246
    • Huston, P.L.1    Pignatello, J.J.2
  • 6
    • 0032592419 scopus 로고    scopus 로고
    • The removal of low levels of organics from aqueous solutions using Fe(II) and hydrogen peroxide formed in situ at gas diffusion electrodes
    • Harrington T., Pletcher D. The removal of low levels of organics from aqueous solutions using Fe(II) and hydrogen peroxide formed in situ at gas diffusion electrodes. J. Electrochem. Soc. 1999, 146:2983-2989.
    • (1999) J. Electrochem. Soc. , vol.146 , pp. 2983-2989
    • Harrington, T.1    Pletcher, D.2
  • 8
    • 69549109859 scopus 로고    scopus 로고
    • Efficient hydrogen peroxide generation from organic matter in a bioelectrochemical system
    • Rozendal R.A., Leonne E., Keller J., Rabaey K. Efficient hydrogen peroxide generation from organic matter in a bioelectrochemical system. Electrochem. Commun. 2009, 11:1752-1755.
    • (2009) Electrochem. Commun. , vol.11 , pp. 1752-1755
    • Rozendal, R.A.1    Leonne, E.2    Keller, J.3    Rabaey, K.4
  • 9
    • 58749093893 scopus 로고    scopus 로고
    • Simultaneous processes of electricity generation and p-nitrophenol degradation in a microbial fuel cell
    • Zhu X., Ni J. Simultaneous processes of electricity generation and p-nitrophenol degradation in a microbial fuel cell. Electrochem. Commun. 2009, 11:274-277.
    • (2009) Electrochem. Commun. , vol.11 , pp. 274-277
    • Zhu, X.1    Ni, J.2
  • 10
    • 77749260969 scopus 로고    scopus 로고
    • Bio-electro-Fenton process driven by microbial fuel cell for wastewater treatment
    • Feng C.H., Li F.B., Mai H.J., Li X.Z. Bio-electro-Fenton process driven by microbial fuel cell for wastewater treatment. Environ. Sci. Technol. 2010, 44:1875-1880.
    • (2010) Environ. Sci. Technol. , vol.44 , pp. 1875-1880
    • Feng, C.H.1    Li, F.B.2    Mai, H.J.3    Li, X.Z.4
  • 11
    • 33846826974 scopus 로고    scopus 로고
    • Kinetic modeling of electro-Fenton reaction in aqueous solution
    • Liu H., Li X.Z., Leng Y.J., Wang C. Kinetic modeling of electro-Fenton reaction in aqueous solution. Water Res. 2007, 41:1161-1167.
    • (2007) Water Res. , vol.41 , pp. 1161-1167
    • Liu, H.1    Li, X.Z.2    Leng, Y.J.3    Wang, C.4
  • 12
    • 71549117090 scopus 로고    scopus 로고
    • In situ Fenton-enhanced cathodic reaction for sustainable increased electricity generation in microbial fuel cells
    • Zhuang L., Zhou S., Li Y., Liu T., Huang D. In situ Fenton-enhanced cathodic reaction for sustainable increased electricity generation in microbial fuel cells. J. Power Sources 2010, 195:1379-1382.
    • (2010) J. Power Sources , vol.195 , pp. 1379-1382
    • Zhuang, L.1    Zhou, S.2    Li, Y.3    Liu, T.4    Huang, D.5
  • 13
    • 65049085916 scopus 로고    scopus 로고
    • Substrate cross-conduction effect on the performance of serially connected microbial fuel cell stack
    • Zhuang L., Zhou S. Substrate cross-conduction effect on the performance of serially connected microbial fuel cell stack. Electrochem. Commun. 2009, 11:937-940.
    • (2009) Electrochem. Commun. , vol.11 , pp. 937-940
    • Zhuang, L.1    Zhou, S.2
  • 14
    • 0003425384 scopus 로고    scopus 로고
    • American Public Health Association, Washington, USA, American Public Health Association (APHA)
    • American Public Health Association (APHA) Standard Methods for the Examination of Water and Wastewater 1998, American Public Health Association, Washington, USA.
    • (1998) Standard Methods for the Examination of Water and Wastewater
  • 15
    • 43049125415 scopus 로고    scopus 로고
    • Carbon sponge as a new cathode material for the electro-Fenton process: Comparison with carbon felt cathode and application to degradation of synthetic dye basic blue 3 in aqueous medium
    • Özcan A., Şahin Y., Koparal A.S., Oturan M.A. Carbon sponge as a new cathode material for the electro-Fenton process: Comparison with carbon felt cathode and application to degradation of synthetic dye basic blue 3 in aqueous medium. J. Electroanal. Chem. 2008, 616:71-78.
    • (2008) J. Electroanal. Chem. , vol.616 , pp. 71-78
    • Özcan, A.1    Şahin, Y.2    Koparal, A.S.3    Oturan, M.A.4
  • 17
    • 54749104266 scopus 로고    scopus 로고
    • PH dependence of Fenton reagent generation and As(III) oxidation and removal by corrosion of zero valent iron in aerated water
    • Katsoyiannis A.I., Ruettimann T., Hug J.S. pH dependence of Fenton reagent generation and As(III) oxidation and removal by corrosion of zero valent iron in aerated water. Environ. Sci. Technol. 2008, 42:7424-7430.
    • (2008) Environ. Sci. Technol. , vol.42 , pp. 7424-7430
    • Katsoyiannis, A.I.1    Ruettimann, T.2    Hug, J.S.3
  • 18
    • 34047258197 scopus 로고    scopus 로고
    • 3 core-shell nanowires as iron reagent. 1. Efficient degradation of Rhodamine B by a novel sono-Fenton process
    • 3 core-shell nanowires as iron reagent. 1. Efficient degradation of Rhodamine B by a novel sono-Fenton process. J. Phys. Chem. C 2007, 111:4087-4093.
    • (2007) J. Phys. Chem. C , vol.111 , pp. 4087-4093
    • Ai, Z.H.1    Lu, L.R.2    Li, J.P.3    Zhang, L.Z.4    Qiu, J.R.5    Wu, M.H.6
  • 19
    • 61349084203 scopus 로고    scopus 로고
    • Design of a neutral electro-Fenton system with Fe@Fe2O3/ACF composite cathode for wastewater treatment
    • Li J., Ai Z., Zhang L. Design of a neutral electro-Fenton system with Fe@Fe2O3/ACF composite cathode for wastewater treatment. J. Hazard. Mater. 2009, 164:18-25.
    • (2009) J. Hazard. Mater. , vol.164 , pp. 18-25
    • Li, J.1    Ai, Z.2    Zhang, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.