메뉴 건너뛰기




Volumn , Issue , 2010, Pages 743-748

Medical cyber physical systems

Author keywords

Cyber physical systems; High confidence medical systems; Medical cyber physical systems; Medical device interoperability compositionality; Physiological closed loop

Indexed keywords

CLOSED LOOPS; CURRENT TRENDS; CYBER-PHYSICAL SYSTEMS; MEDICAL DEVICES; MEDICAL SYSTEMS; NETWORK CONNECTIVITY; NEW OPPORTUNITIES; RESEARCH AND DEVELOPMENT;

EID: 77956216385     PISSN: 0738100X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1145/1837274.1837463     Document Type: Conference Paper
Times cited : (168)

References (23)
  • 1
    • 76349115594 scopus 로고    scopus 로고
    • Developing next generation telehealth tools and technologies: Patients, systems, and data perspectives
    • Jan/Feb
    • M. J. Ackerman, L. P. Burgess, R. Filart, I. Lee, and R. K. Poropatich. Developing next generation telehealth tools and technologies: Patients, systems, and data perspectives. Telemedicine and e-Health, 16(1):93-95, Jan/Feb 2010.
    • (2010) Telemedicine and E-Health , vol.16 , Issue.1 , pp. 93-95
    • Ackerman, M.J.1    Burgess, L.P.2    Filart, R.3    Lee, I.4    Poropatich, R.K.5
  • 2
    • 0033930312 scopus 로고    scopus 로고
    • Good design practice for medical devices and equipment, Part II: Design for verification
    • K. Alexander and P. Clarkson. Good design practice for medical devices and equipment, Part II: design for verification. Journal of Medical Engineering & Technology, 24(2):53-62, 2000.
    • (2000) Journal of Medical Engineering & Technology , vol.24 , Issue.2 , pp. 53-62
    • Alexander, K.1    Clarkson, P.2
  • 3
    • 67650547256 scopus 로고    scopus 로고
    • Synchronizing an x-ray and anesthesia machine ventilator: A medical device interoperability case study
    • January
    • D. Arney, J. M. Goldman, S. F. Whitehead, and I. Lee. Synchronizing an x-ray and anesthesia machine ventilator: A medical device interoperability case study. In BIODEVICES 2009, pages 52 - 60, January 2009.
    • (2009) BIODEVICES 2009 , pp. 52-60
    • Arney, D.1    Goldman, J.M.2    Whitehead, S.F.3    Lee, I.4
  • 8
    • 0032063333 scopus 로고    scopus 로고
    • Treatment interference in acutely and critically ill adults
    • May
    • M. B. Happ. Treatment interference in acutely and critically ill adults. American Journal of Critical Care, 7(3):224-235, May 1998.
    • (1998) American Journal of Critical Care , vol.7 , Issue.3 , pp. 224-235
    • Happ, M.B.1
  • 10
    • 76349104931 scopus 로고    scopus 로고
    • High Confidence Software and Systems Coordinating Group. A Research and Development Needs Report NCO/NITRD February
    • High Confidence Software and Systems Coordinating Group. High-confidence medical devices: Cyber-physical systems for 21st century health care. A Research and Development Needs Report, NCO/NITRD, February 2009.
    • (2009) High-confidence Medical Devices: Cyber-physical Systems for 21st Century Health Care
  • 12
    • 84991042142 scopus 로고    scopus 로고
    • D. Jackson, M. Thomas, and L. I. Millett, editors. National Academies Press, May. Committee on Certifiably Dependable Software Systems, National Research Council
    • D. Jackson, M. Thomas, and L. I. Millett, editors. Software for Dependable Systems: Sufficient Evidence? National Academies Press, May 2007. Committee on Certifiably Dependable Software Systems, National Research Council.
    • (2007) Software for Dependable Systems: Sufficient Evidence?
  • 15
    • 67650564029 scopus 로고    scopus 로고
    • Turn your alarms on
    • A. S. Lofsky. Turn Your Alarms On. APSF Newsletter, 19(4):43, 2004.
    • (2004) APSF Newsletter , vol.19 , Issue.4 , pp. 43
    • Lofsky, A.S.1
  • 16
    • 34250885127 scopus 로고    scopus 로고
    • Morphine in postoperative patients: Pharmacokinetics and pharmacodynamics of metabolites
    • J. X. Mazoit, K. Butscher, and K. Samii. Morphine in postoperative patients: Pharmacokinetics and pharmacodynamics of metabolites. Anesthesia and Analgesia, 105(1):70-78, 2007.
    • (2007) Anesthesia and Analgesia , vol.105 , Issue.1 , pp. 70-78
    • Mazoit, J.X.1    Butscher, K.2    Samii, K.3
  • 17
    • 0031272802 scopus 로고    scopus 로고
    • Supervisory control of families of linear set-point controllers - Part 2: Robustness
    • Nov.
    • A. S. Morse. Supervisory control of families of linear set-point controllers - Part 2: Robustness. IEEE Transactions on Automatic Control, pages 1500-1515, Nov. 1997.
    • (1997) IEEE Transactions on Automatic Control , pp. 1500-1515
    • Morse, A.S.1
  • 21
    • 70350787997 scopus 로고    scopus 로고
    • Checking safety properties using induction and a sat-solver
    • FMCAD '00: Proceedings of the Third International Conference on Formal Methods in Computer-Aided Design
    • M. Sheeran, S. Singh, and G. Stålmarck. Checking safety properties using induction and a sat-solver. In FMCAD '00: Proceedings of the Third International Conference on Formal Methods in Computer-Aided Design, volume 1954 of LNCS, pages 108-125, 2000.
    • (2000) LNCS , vol.1954 , pp. 108-125
    • Sheeran, M.1    Singh, S.2    Stålmarck, G.3
  • 23
    • 0038805213 scopus 로고    scopus 로고
    • Programming errors contribute to death from patient-controlled analgesia: Case report and estimate of probability
    • K. J. Vicente, K. Kada-Bekhaled, G. Hillel, A. Cassano, and B. A. Orser. Programming errors contribute to death from patient-controlled analgesia: case report and estimate of probability. Canadian Journal of Anesthesiology, 50(4):328-332, 2003.
    • (2003) Canadian Journal of Anesthesiology , vol.50 , Issue.4 , pp. 328-332
    • Vicente, K.J.1    Kada-Bekhaled, K.2    Hillel, G.3    Cassano, A.4    Orser, B.A.5