메뉴 건너뛰기




Volumn 5, Issue 6, 2010, Pages

Drug-eluting versus bare-metal stent for treatment of saphenous vein grafts: A meta-analysis

Author keywords

[No Author keywords available]

Indexed keywords

PACLITAXEL; RAPAMYCIN; DRUG; METAL;

EID: 77956202085     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0011040     Document Type: Article
Times cited : (47)

References (51)
  • 2
    • 77958617618 scopus 로고    scopus 로고
    • Stent Use in Saphenous Vein Bypass Graft Percutaneous Coronary Interventions: A Report from the American College of Cardiology - National Cardiovascular Data Registry (abstract). presented at American College of Cardiology ACC scientific meetings 2010, March 14; Atlanta, Georgia
    • Brilakis ES, Wang TY, Rao SV, Banerjee S, Dai D, et al. (2010) Frequency and Predictors of Drug-Eluting Stent Use in Saphenous Vein Bypass Graft Percutaneous Coronary Interventions: A Report from the American College of Cardiology - National Cardiovascular Data Registry (abstract). presented at American College of Cardiology ACC scientific meetings 2010, March 14; Atlanta, Georgia.
    • (2010) Frequency and Predictors of Drug-Eluting
    • Brilakis, E.S.1    Wang, T.Y.2    Rao, S.V.3    Banerjee, S.4    Dai, D.5
  • 3
    • 72449145890 scopus 로고    scopus 로고
    • Comparison of plaque sealing with paclitaxel-eluting stents versus medical therapy for the treatment of moderate nonsignificant saphenous vein graft lesions: The moderate vein graft lesion stenting with the taxus stent and intravascular ultrasound (VELETI) pilot trial
    • Rodes-Cabau J, Bertrand OF, Larose E, Dery JP, Rinfret S, et al. (2009) Comparison of plaque sealing with paclitaxel-eluting stents versus medical therapy for the treatment of moderate nonsignificant saphenous vein graft lesions: the moderate vein graft lesion stenting with the taxus stent and intravascular ultrasound (VELETI) pilot trial. Circulation 120: 1978-1986.
    • (2009) Circulation , vol.120 , pp. 1978-1986
    • Rodes-Cabau, J.1    Bertrand, O.F.2    Larose, E.3    Dery, J.P.4    Rinfret, S.5
  • 4
    • 58349112528 scopus 로고    scopus 로고
    • Fractional flow reserve versus angiography for guiding percutaneous coronary intervention
    • Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, et al. (2009) Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med 360: 213-224.
    • (2009) N Engl J Med , vol.360 , pp. 213-224
    • Tonino, P.A.1    de Bruyne, B.2    Pijls, N.H.3    Siebert, U.4    Ikeno, F.5
  • 5
    • 0036087155 scopus 로고    scopus 로고
    • Accelerated atherosclerosis in saphenous vein bypass grafts: A spectrum of diffuse plaque instability
    • Safian RD (2002) Accelerated atherosclerosis in saphenous vein bypass grafts: a spectrum of diffuse plaque instability. Prog Cardiovasc Dis 44: 437-448.
    • (2002) Prog Cardiovasc Dis , vol.44 , pp. 437-448
    • Safian, R.D.1
  • 6
    • 33845410666 scopus 로고    scopus 로고
    • Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts: Six-month angiographic, intravascular ultrasound, and clinical follow-up of the RRISC Trial
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, et al. (2006) Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in diseased saphenous vein grafts: six-month angiographic, intravascular ultrasound, and clinical follow-up of the RRISC Trial. J Am Coll Cardiol 48: 2423-2431.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2423-2431
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    van den Heuvel, P.4    Convens, C.5
  • 7
    • 57049165763 scopus 로고    scopus 로고
    • Drug-eluting stents compared with bare metal stents improve late outcome after saphenous vein graft but not after large native vessel interventions
    • Jeger RV, Schneiter S, Kaiser C, Bonetti PO, Brunner-La Rocca H, et al. (2009) Drug-eluting stents compared with bare metal stents improve late outcome after saphenous vein graft but not after large native vessel interventions. Cardiology 112: 49-55.
    • (2009) Cardiology , vol.112 , pp. 49-55
    • Jeger, R.V.1    Schneiter, S.2    Kaiser, C.3    Bonetti, P.O.4    Brunner-La Rocca, H.5
  • 8
    • 61549089702 scopus 로고    scopus 로고
    • A randomized controlled trial of a paclitaxel-eluting stent versus a similar baremetal stent in saphenous vein graft lesions the SOS (Stenting of Saphenous Vein Grafts) trial
    • Brilakis ES, Lichtenwalter C, de Lemos JA, Roesle M, Obel O, et al. (2009) A randomized controlled trial of a paclitaxel-eluting stent versus a similar baremetal stent in saphenous vein graft lesions the SOS (Stenting of Saphenous Vein Grafts) trial. J Am Coll Cardiol 53: 919-928.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 919-928
    • Brilakis, E.S.1    Lichtenwalter, C.2    de Lemos, J.A.3    Roesle, M.4    Obel, O.5
  • 9
    • 38949137886 scopus 로고    scopus 로고
    • Long-term histological and immunohistochemical findings in human venous aorto-coronary bypass grafts
    • Ribichini F, Pugno F, Ferrero V, Wijns W, Vacca G, et al. (2008) Long-term histological and immunohistochemical findings in human venous aorto-coronary bypass grafts. Clin Sci (Lond) 114: 211-220.
    • (2008) Clin Sci (Lond) , vol.114 , pp. 211-220
    • Ribichini, F.1    Pugno, F.2    Ferrero, V.3    Wijns, W.4    Vacca, G.5
  • 10
    • 0015449232 scopus 로고
    • Changes in vein grafts following aortocoronary bypass induced by pressure and ischemia
    • Brody WR, Kosek JC, Angell WW (1972) Changes in vein grafts following aortocoronary bypass induced by pressure and ischemia. J Thorac Cardiovasc Surg 64: 847-854.
    • (1972) J Thorac Cardiovasc Surg , vol.64 , pp. 847-854
    • Brody, W.R.1    Kosek, J.C.2    Angell, W.W.3
  • 11
    • 0017345456 scopus 로고
    • Accelerated ''atherosclerosis''. A morphologic study of 97 saphenous vein coronary artery bypass grafts
    • Bulkley BH, Hutchins GM (1977) Accelerated ''atherosclerosis''. A morphologic study of 97 saphenous vein coronary artery bypass grafts. Circulation 55: 163-169.
    • (1977) Circulation , vol.55 , pp. 163-169
    • Bulkley, B.H.1    Hutchins, G.M.2
  • 13
    • 0030922816 scopus 로고    scopus 로고
    • Bias in meta-analysis detected by a simple, graphical test
    • Egger M, Davey Smith G, Schneider M, Minder C (1997) Bias in meta-analysis detected by a simple, graphical test. BMJ 315: 629-634.
    • (1997) BMJ , vol.315 , pp. 629-634
    • Egger, M.1    Davey Smith, G.2    Schneider, M.3    Minder, C.4
  • 14
    • 17844406885 scopus 로고    scopus 로고
    • Evaluating the role of quality assessment of primary studies in systematic reviews of cancer practice guidelines
    • Brouwers MC, Johnston ME, Charette ML, Hanna SE, Jadad AR, et al. (2005) Evaluating the role of quality assessment of primary studies in systematic reviews of cancer practice guidelines. BMC Med Res Methodol 5: 8.
    • (2005) BMC Med Res Methodol , vol.5 , pp. 8
    • Brouwers, M.C.1    Johnston, M.E.2    Charette, M.L.3    Hanna, S.E.4    Jadad, A.R.5
  • 15
    • 0345583669 scopus 로고    scopus 로고
    • The hazards of scoring the quality of clinical trials for meta-analysis
    • Juni P, Witschi A, Bloch R, Egger M (1999) The hazards of scoring the quality of clinical trials for meta-analysis. JAMA 282: 1054-1060.
    • (1999) JAMA , vol.282 , pp. 1054-1060
    • Juni, P.1    Witschi, A.2    Bloch, R.3    Egger, M.4
  • 16
    • 84952529285 scopus 로고
    • The inverse of the Freeman-Tukey double arcsine transformation
    • Miller J (1978) The inverse of the Freeman-Tukey double arcsine transformation. The American Statistician 32.
    • (1978) The American Statistician , pp. 32
    • Miller, J.1
  • 17
    • 77955238582 scopus 로고    scopus 로고
    • R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. ISBN 3-900051-07-0
    • R Development Core Team 2009
    • R Development Core Team (2009) R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. ISBN 3-900051-07-0, R project website (2010) http://www.R-project.org.
    • (2010) R Project Website
  • 18
    • 84947762347 scopus 로고    scopus 로고
    • Statistical Meta-Analysis with Applications
    • NJ: Wiley-Interscience
    • Hartung J, Knapp G, Sinha BK (2008) Statistical Meta-Analysis with Applications. Hoboken, NJ: Wiley-Interscience.
    • (2008) Hoboken
    • Hartung, J.1    Knapp, G.2    Sinha, B.K.3
  • 19
    • 34447120247 scopus 로고    scopus 로고
    • Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts: Results from the randomized DELAYED RRISC Trial
    • Vermeersch P, Agostoni P, Verheye S, Van den Heuvel P, Convens C, et al. (2007) Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts: results from the randomized DELAYED RRISC Trial. J Am Coll Cardiol 50: 261-267.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 261-267
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3    van den Heuvel, P.4    Convens, C.5
  • 20
    • 70349216489 scopus 로고    scopus 로고
    • Drugeluting versus bare-metal stents for treating saphenous vein grafts
    • Shishehbor MH, Hawi R, Singh IM, Tuzcu EM, Bhatt DL, et al. (2009) Drugeluting versus bare-metal stents for treating saphenous vein grafts. Am Heart J 158: 637-643.
    • (2009) Am Heart J , vol.158 , pp. 637-643
    • Shishehbor, M.H.1    Hawi, R.2    Singh, I.M.3    Tuzcu, E.M.4    Bhatt, D.L.5
  • 21
    • 29244439559 scopus 로고    scopus 로고
    • Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention
    • Chu WW, Rha SW, Kuchulakanti PK, Cheneau E, Torguson R, et al. (2006) Efficacy of sirolimus-eluting stents compared with bare metal stents for saphenous vein graft intervention. Am J Cardiol 97: 34-37.
    • (2006) Am J Cardiol , vol.97 , pp. 34-37
    • Chu, W.W.1    Rha, S.W.2    Kuchulakanti, P.K.3    Cheneau, E.4    Torguson, R.5
  • 22
    • 20144389837 scopus 로고    scopus 로고
    • Treatment of saphenous vein graft lesions with drug-eluting stents: Immediate and midterm outcome
    • Ge L, Iakovou I, Sangiorgi GM, Chieffo A, Melzi G (2005) Treatment of saphenous vein graft lesions with drug-eluting stents: immediate and midterm outcome. J Am Coll Cardiol 45: 989-994.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 989-994
    • Ge, L.1    Iakovou, I.2    Sangiorgi, G.M.3    Chieffo, A.4    Melzi, G.5
  • 23
    • 28844482806 scopus 로고    scopus 로고
    • Drug-eluting stenting is superior to bare metal stenting in saphenous vein grafts
    • Lee MS, Shah AP, Aragon J, Jamali A, Dohad S, et al. (2005) Drug-eluting stenting is superior to bare metal stenting in saphenous vein grafts. Catheter Cardiovasc Interv 66: 507-511.
    • (2005) Catheter Cardiovasc Interv , vol.66 , pp. 507-511
    • Lee, M.S.1    Shah, A.P.2    Aragon, J.3    Jamali, A.4    Dohad, S.5
  • 24
    • 34147197569 scopus 로고    scopus 로고
    • Implantation of paclitaxel-eluting stents in saphenous vein grafts: Clinical and angiographic follow-up results from a multicentre study
    • Hoffmann R, Pohl T, Koster R, Blindt R, Boeckstegers P, et al. (2007) Implantation of paclitaxel-eluting stents in saphenous vein grafts: clinical and angiographic follow-up results from a multicentre study. Heart 93: 331-334.
    • (2007) Heart , vol.93 , pp. 331-334
    • Hoffmann, R.1    Pohl, T.2    Koster, R.3    Blindt, R.4    Boeckstegers, P.5
  • 25
    • 33846927284 scopus 로고    scopus 로고
    • Comparison of the slow-release polymer-based paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions
    • Wohrle J, Nusser T, Kestler HA, Kochs M, Hombach V (2007) Comparison of the slow-release polymer-based paclitaxel-eluting Taxus-Express stent with the bare-metal Express stent for saphenous vein graft interventions. Clin Res Cardiol 96: 70-76.
    • (2007) Clin Res Cardiol , vol.96 , pp. 70-76
    • Wohrle, J.1    Nusser, T.2    Kestler, H.A.3    Kochs, M.4    Hombach, V.5
  • 26
    • 34848856445 scopus 로고    scopus 로고
    • Utility of sirolimus-eluting Cypher stents to reduce 12-month target vessel revascularization in saphenous vein graft stenoses: Results of a multicenter 350-patient casecontrol study
    • Ellis SG, Kandzari D, Kereiakes DJ, Pichard A, Huber K, et al. (2007) Utility of sirolimus-eluting Cypher stents to reduce 12-month target vessel revascularization in saphenous vein graft stenoses: results of a multicenter 350-patient casecontrol study. J Invasive Cardiol 19: 404-409.
    • (2007) J Invasive Cardiol , vol.19 , pp. 404-409
    • Ellis, S.G.1    Kandzari, D.2    Kereiakes, D.J.3    Pichard, A.4    Huber, K.5
  • 27
    • 36549008097 scopus 로고    scopus 로고
    • Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease
    • Minutello RM, Bhagan S, Sharma A, Slotwiner AJ, Feldman DN, et al. (2007) Long-term clinical benefit of sirolimus-eluting stents compared to bare metal stents in the treatment of saphenous vein graft disease. J Interv Cardiol 20: 458-465.
    • (2007) J Interv Cardiol , vol.20 , pp. 458-465
    • Minutello, R.M.1    Bhagan, S.2    Sharma, A.3    Slotwiner, A.J.4    Feldman, D.N.5
  • 29
    • 77955235789 scopus 로고    scopus 로고
    • Pavlides G, et al. (2006) Effectiveness of drug-eluting stents in the treatment of bypass graft lesions (abstract)
    • Voudris V, Kalianos C, Patsilinakos S, Manginas A, Pavlides G, et al. (2006) Effectiveness of drug-eluting stents in the treatment of bypass graft lesions (abstract). Eur Heart J 2006, 27(Abstract Suppl): 925.
    • (2006) Eur Heart J , vol.27 , Issue.SUPPL. , pp. 925
    • Voudris, V.1    Kalianos, C.2    Patsilinakos, S.3    Manginas, A.4
  • 31
  • 32
    • 47549096848 scopus 로고    scopus 로고
    • Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts
    • Gioia G, Benassi A, Mohendra R, Chowdhury K, Masood I, et al. (2008) Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts. Catheter Cardiovasc Interv 72: 13-20.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 13-20
    • Gioia, G.1    Benassi, A.2    Mohendra, R.3    Chowdhury, K.4    Masood, I.5
  • 33
    • 59249097377 scopus 로고    scopus 로고
    • Beneficial 2- years results of drug-eluting stents in saphenous vein graft lesions
    • Assali A, Raz Y, Vaknin-Assa H, Ben-Dor I, Brosh D, et al. (2008) Beneficial 2- years results of drug-eluting stents in saphenous vein graft lesions. EuroIntervention 4: 108-114.
    • (2008) EuroIntervention , vol.4 , pp. 108-114
    • Assali, A.1    Raz, Y.2    Vaknin-Assa, H.3    Ben-Dor, I.4    Brosh, D.5
  • 34
    • 59049086905 scopus 로고    scopus 로고
    • Four-year safety and efficacy of the unrestricted use of sirolimus- and paclitaxeleluting stents in coronary artery bypass grafts
    • van Twisk PH, Daemen J, Kukreja N, van Domburg RT, Serruys PW (2008) Four-year safety and efficacy of the unrestricted use of sirolimus- and paclitaxeleluting stents in coronary artery bypass grafts. EuroIntervention 4: 311-317.
    • (2008) EuroIntervention , vol.4 , pp. 311-317
    • van Twisk, P.H.1    Daemen, J.2    Kukreja, N.3    van Domburg, R.T.4    Serruys, P.W.5
  • 35
    • 41249085132 scopus 로고    scopus 로고
    • Long-term outcomes with drug-eluting stents versus bare metal stents in the treatment of saphenous vein graft disease (results from the REgistro Regionale AngiopLastiche Emilia-Romagna registry)
    • Vignali L, Saia F, Manari A, Santarelli A, Rubboli A, et al. (2008) Long-term outcomes with drug-eluting stents versus bare metal stents in the treatment of saphenous vein graft disease (results from the REgistro Regionale AngiopLastiche Emilia-Romagna registry). Am J Cardiol 101: 947-952.
    • (2008) Am J Cardiol , vol.101 , pp. 947-952
    • Vignali, L.1    Saia, F.2    Manari, A.3    Santarelli, A.4    Rubboli, A.5
  • 37
    • 51749099574 scopus 로고    scopus 로고
    • Drug-eluting stents versus bare metal stents for narrowing in saphenous vein grafts
    • Okabe T, Lindsay J, Buch AN, Steinberg DH, Roy P, et al. (2008) Drug-eluting stents versus bare metal stents for narrowing in saphenous vein grafts. Am J Cardiol 102: 530-534.
    • (2008) Am J Cardiol , vol.102 , pp. 530-534
    • Okabe, T.1    Lindsay, J.2    Buch, A.N.3    Steinberg, D.H.4    Roy, P.5
  • 38
    • 47549089025 scopus 로고    scopus 로고
    • Late outcomes of drug-eluting versus bare metal stents in saphenous vein grafts: Propensity score analysis
    • Applegate RJ, Sacrinty M, Kutcher M, Santos R, Gandhi S, et al. (2008) Late outcomes of drug-eluting versus bare metal stents in saphenous vein grafts: Propensity score analysis. Catheter Cardiovasc Interv 72: 7-12.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 7-12
    • Applegate, R.J.1    Sacrinty, M.2    Kutcher, M.3    Santos, R.4    Gandhi, S.5
  • 39
    • 59749085264 scopus 로고    scopus 로고
    • Comparison of drug-eluting and bare metal stents in saphenous vein grafts. Immediate and long-term results
    • Lozano I, Garcia-Camarero T, Carrillo P, Baz JA, de la Torre JM, et al. (2009) [Comparison of drug-eluting and bare metal stents in saphenous vein grafts. Immediate and long-term results]. Rev Esp Cardiol 62: 39-47.
    • (2009) Rev Esp Cardiol , vol.62 , pp. 39-47
    • Lozano, I.1    Garcia-Camarero, T.2    Carrillo, P.3    Baz, J.A.4    de la Torre, J.M.5
  • 40
    • 45849138540 scopus 로고    scopus 로고
    • Longterm clinical outcomes of real-world experience using sirolimus-eluting stents in saphenous vein graft disease
    • Ramana RK, Ronan A, Cohoon K, Homan D, Sutherland J, et al. (2008) Longterm clinical outcomes of real-world experience using sirolimus-eluting stents in saphenous vein graft disease. Catheter Cardiovasc Interv 71: 886-893.
    • (2008) Catheter Cardiovasc Interv , vol.71 , pp. 886-893
    • Ramana, R.K.1    Ronan, A.2    Cohoon, K.3    Homan, D.4    Sutherland, J.5
  • 41
    • 45849134854 scopus 로고    scopus 로고
    • Immediate procedural and long-term clinical outcomes following drug-eluting stent implantation to ostial saphenous vein graft lesions
    • Kaplan S, Barlis P, Kiris A, Dimopoulos K, Celik S, et al. (2008) Immediate procedural and long-term clinical outcomes following drug-eluting stent implantation to ostial saphenous vein graft lesions. Acute Card Care 10: 88-92.
    • (2008) Acute Card Care , vol.10 , pp. 88-92
    • Kaplan, S.1    Barlis, P.2    Kiris, A.3    Dimopoulos, K.4    Celik, S.5
  • 43
    • 77955247118 scopus 로고    scopus 로고
    • A comparison of the long-term (2 year) safety and efficacy of drug-eluting and bare-metal stent implantation in saphenous vein grafts (abstract)
    • Latib A, Ferri L, Cosgrave J, Godino C, Romagnoli E, et al. (2008) A comparison of the long-term (2 year) safety and efficacy of drug-eluting and bare-metal stent implantation in saphenous vein grafts (abstract). Eur Heart J 29 (Supplement): 455-456.
    • (2008) Eur Heart J , vol.29 , Issue.SUPPL. , pp. 455-456
    • Latib, A.1    Ferri, L.2    Cosgrave, J.3    Godino, C.4    Romagnoli, E.5
  • 45
    • 70349224293 scopus 로고    scopus 로고
    • Clinical presentation and angiographic characteristics of saphenous vein graft failure after stenting: Insights from the SOS (stenting of saphenous vein grafts) trial
    • Lichtenwalter C, de Lemos JA, Roesle M, Obel O, Holper EM, et al. (2009) Clinical presentation and angiographic characteristics of saphenous vein graft failure after stenting: insights from the SOS (stenting of saphenous vein grafts) trial. JACC Cardiovasc Interv 2: 855-860.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 855-860
    • Lichtenwalter, C.1    de Lemos, J.A.2    Roesle, M.3    Obel, O.4    Holper, E.M.5
  • 46
    • 76849115417 scopus 로고    scopus 로고
    • Drug-eluting versus bare metal stents-a one horse race
    • Meier P, Gurm HS Drug-eluting versus bare metal stents-a one horse race? J Invasive Cardiol 22: 33-34.
    • J Invasive Cardiol , vol.22 , pp. 33-34
    • Meier, P.1    Gurm, H.S.2
  • 47
    • 77649267515 scopus 로고    scopus 로고
    • Temporal Trends in the Use of Drug-eluting Stents for Approved and Off-label Indications: A Longitudinal Analysis of a Large Multicenter Percutaneous Coronary Intervention Registry
    • Gualano SK, Gurm HS, Share D, Smith D, Aronow HD, et al. (2010) Temporal Trends in the Use of Drug-eluting Stents for Approved and Off-label Indications: A Longitudinal Analysis of a Large Multicenter Percutaneous Coronary Intervention Registry. Clin Cardiol 33: 111-116.
    • (2010) Clin Cardiol , vol.33 , pp. 111-116
    • Gualano, S.K.1    Gurm, H.S.2    Share, D.3    Smith, D.4    Aronow, H.D.5
  • 48
  • 49
    • 70449486864 scopus 로고    scopus 로고
    • Outcomes with drug-eluting versus bare-metal stents in saphenous vein graft intervention results from the STENT (strategic transcatheter evaluation of new therapies) group
    • Brodie BR, Wilson H, Stuckey T, Nussbaum M, Laurent S, et al. (2009) Outcomes with drug-eluting versus bare-metal stents in saphenous vein graft intervention results from the STENT (strategic transcatheter evaluation of new therapies) group. JACC Cardiovasc Interv 2: 1105-1112.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 1105-1112
    • Brodie, B.R.1    Wilson, H.2    Stuckey, T.3    Nussbaum, M.4    Laurent, S.5
  • 50
    • 40849150745 scopus 로고    scopus 로고
    • Comparative safety and efficacy of a sirolimus-eluting versus paclitaxel-eluting stent: A meta-analysis
    • Gurm HS, Boyden T, Welch KB (2008) Comparative safety and efficacy of a sirolimus-eluting versus paclitaxel-eluting stent: a meta-analysis. Am Heart J 155: 630-639.
    • (2008) Am Heart J , vol.155 , pp. 630-639
    • Gurm, H.S.1    Boyden, T.2    Welch, K.B.3
  • 51
    • 77649223869 scopus 로고    scopus 로고
    • Short term and intermediate term comparison of endarterectomy versus stenting for carotid artery stenosis: Systematic review and meta-analysis of randomised controlled clinical trials
    • Meier P, Knapp G, Tamhane U, Chaturvedi S, Gurm HS (2010) Short term and intermediate term comparison of endarterectomy versus stenting for carotid artery stenosis: systematic review and meta-analysis of randomised controlled clinical trials. BMJ 340: c467.
    • (2010) BMJ , vol.c467 , pp. 340
    • Meier, P.1    Knapp, G.2    Tamhane, U.3    Chaturvedi, S.4    Gurm, H.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.