메뉴 건너뛰기




Volumn 18, Issue 5, 2009, Pages 474-478

Obtaining blood samples from peripheral intravenous catheters: Best practice?

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD SAMPLING; CATHETERIZATION; HEMOLYSIS; HUMAN; INSTRUMENTATION; METHODOLOGY; QUALITY CONTROL;

EID: 77956197602     PISSN: 10623264     EISSN: None     Source Type: Journal    
DOI: 10.4037/ajcc2009686     Document Type: Article
Times cited : (30)

References (11)
  • 1
    • 0036239525 scopus 로고    scopus 로고
    • Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists
    • Burns E, Yoshikawa N. Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists. Lab Med. 2002;33(5):378-380.
    • (2002) Lab Med , vol.33 , Issue.5 , pp. 378-380
    • Burns, E.1    Yoshikawa, N.2
  • 2
    • 38349129049 scopus 로고    scopus 로고
    • Nursing blood specimen collection techniques and hemolysis rates in an emergency department: analysis of venipunctures versus intravenous catheter collection techniques
    • Lowe G, Stike R, Pollack M, et al. Nursing blood specimen collection techniques and hemolysis rates in an emergency department: analysis of venipunctures versus intravenous catheter collection techniques. J Emerg Nurs. 2008;34(1):26-32.
    • (2008) J Emerg Nurs , vol.34 , Issue.1 , pp. 26-32
    • Lowe, G.1    Stike, R.2    Pollack, M.3
  • 3
    • 24044454046 scopus 로고    scopus 로고
    • Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department
    • Dugan L, Leech L, Speroni K, et al. Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department. J Emerg Nurs. 2005; 31(4):338-345.
    • (2005) J Emerg Nurs , vol.31 , Issue.4 , pp. 338-345
    • Dugan, L.1    Leech, L.2    Speroni, K.3
  • 4
    • 0033972513 scopus 로고    scopus 로고
    • Hemolyzed specimens: a reason for rejection or a clinical challenge?
    • Carraro P, Servidio G, Plehani M. Hemolyzed specimens: a reason for rejection or a clinical challenge? Clin Chem. 2000; 46:306-307.
    • (2000) Clin Chem , vol.46 , pp. 306-307
    • Carraro, P.1    Servidio, G.2    Plehani, M.3
  • 5
    • 10344259079 scopus 로고    scopus 로고
    • Blood samples drawn from IV catheters have less hemolysis when 5-ml (vs 10-ml) collection tubes are used
    • Cox S, Dages J, Jarjoura D, et al. Blood samples drawn from IV catheters have less hemolysis when 5-ml (vs 10-ml) collection tubes are used. J Emerg Nurs. 2004;30(6):529-533.
    • (2004) J Emerg Nurs , vol.30 , Issue.6 , pp. 529-533
    • Cox, S.1    Dages, J.2    Jarjoura, D.3
  • 6
    • 0037398606 scopus 로고    scopus 로고
    • The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples
    • Grant M. The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples. J Emerg Nurs. 2003;29(2):116-121.
    • (2003) J Emerg Nurs , vol.29 , Issue.2 , pp. 116-121
    • Grant, M.1
  • 7
    • 0033805947 scopus 로고    scopus 로고
    • Blood sample collection from a peripheral catheter system compared with phlebotomy
    • Seemann S, Reinhardt A. Blood sample collection from a peripheral catheter system compared with phlebotomy. J Intraven Nurs. 2000;23(5):290-297.
    • (2000) J Intraven Nurs , vol.23 , Issue.5 , pp. 290-297
    • Seemann, S.1    Reinhardt, A.2
  • 8
    • 0030342298 scopus 로고    scopus 로고
    • A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples
    • Kennedy C, Angermuller S, King R, et al. A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples. J Emerg Nurs. 1996;22(6):566-569.
    • (1996) J Emerg Nurs , vol.22 , Issue.6 , pp. 566-569
    • Kennedy, C.1    Angermuller, S.2    King, R.3
  • 9
    • 4043107882 scopus 로고    scopus 로고
    • Elevated serum potassium values: the role of preanalytic variables
    • Stankovic A, Smith S. Elevated serum potassium values: the role of preanalytic variables. Am J Clin Pathol. 2004;121(suppl):S105-S112.
    • (2004) Am J Clin Pathol , vol.121 , Issue.SUPPL
    • Stankovic, A.1    Smith, S.2
  • 11
    • 0034702833 scopus 로고    scopus 로고
    • Part 1 Introduction to the international guidelines 2000 for CPR and ECC
    • Classes of recommendations 2000
    • Classes of recommendations 2000. Part 1: Introduction to the international guidelines 2000 for CPR and ECC. Circulation. 2000;102:I-1.
    • (2000) Circulation , vol.102


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.