메뉴 건너뛰기




Volumn 23, Issue 9, 2010, Pages 993-1000

Color Doppler jet area overestimates regurgitant volume when multiple jets are present

Author keywords

Color Doppler jet area; Double orifice repair; Edge to edge repair; Mitral regurgitation; Mitral regurgitation severity; Multiple jets

Indexed keywords

GLYCEROL;

EID: 77956186251     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.echo.2010.06.011     Document Type: Article
Times cited : (52)

References (22)
  • 1
    • 0142008980 scopus 로고    scopus 로고
    • Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography
    • W.A. Zoghbi, M. Enriquez-Sarano, E. Foster, P.A. Grayburn, C.D. Kraft, and R.A. Levine Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography J Am Soc Echocardiogr 16 2003 777 802
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 777-802
    • Zoghbi, W.A.1    Enriquez-Sarano, M.2    Foster, E.3    Grayburn, P.A.4    Kraft, C.D.5    Levine, R.A.6
  • 3
    • 0024389499 scopus 로고
    • Sources of variability for doppler color flow mapping of regurgitant jets in an animal model of mitral regurgitation
    • B.D. Hoit, M. Jones, E.E. Eidbo, W. Elias, and D.J. Sahn Sources of variability for doppler color flow mapping of regurgitant jets in an animal model of mitral regurgitation J Am Coll Cardiol 13 1989 1631 1636
    • (1989) J Am Coll Cardiol , vol.13 , pp. 1631-1636
    • Hoit, B.D.1    Jones, M.2    Eidbo, E.E.3    Elias, W.4    Sahn, D.J.5
  • 4
    • 0024521992 scopus 로고
    • Doppler color flow mapping of simulated in vitro regurgitant jets: Evaluation of the effects of orifice size and hemodynamic variables
    • I.A. Simpson, L.M. Valdes-Cruz, D.J. Sahn, A. Murillo, T. Tamura, and K.J. Chung Doppler color flow mapping of simulated in vitro regurgitant jets: Evaluation of the effects of orifice size and hemodynamic variables J Am Coll Cardiol 13 1989 1195 1207
    • (1989) J Am Coll Cardiol , vol.13 , pp. 1195-1207
    • Simpson, I.A.1    Valdes-Cruz, L.M.2    Sahn, D.J.3    Murillo, A.4    Tamura, T.5    Chung, K.J.6
  • 5
    • 0035189880 scopus 로고    scopus 로고
    • Effects of blood viscosity on proximal flow convergence calculations of regurgitant flow rate and jet dimensions as evaluated by color doppler flow mapping: An in vitro study
    • A. Schmidt, A. Pazin-Filho, O.C. Almeida-Filho, L. Gallo-Junior, J.A. Marin-Neto, and B.C. Maciel Effects of blood viscosity on proximal flow convergence calculations of regurgitant flow rate and jet dimensions as evaluated by color doppler flow mapping: An in vitro study J Am Soc Echocardiogr 14 2001 569 579
    • (2001) J Am Soc Echocardiogr , vol.14 , pp. 569-579
    • Schmidt, A.1    Pazin-Filho, A.2    Almeida-Filho, O.C.3    Gallo-Junior, L.4    Marin-Neto, J.A.5    MacIel, B.C.6
  • 6
    • 0025737199 scopus 로고
    • Impact of impinging wall jet on color doppler quantification of mitral regurgitation
    • C.G. Chen, J.D. Thomas, J. Anconina, P. Harrigan, L. Mueller, and M.H. Picard Impact of impinging wall jet on color doppler quantification of mitral regurgitation Circulation 84 1991 712 720
    • (1991) Circulation , vol.84 , pp. 712-720
    • Chen, C.G.1    Thomas, J.D.2    Anconina, J.3    Harrigan, P.4    Mueller, L.5    Picard, M.H.6
  • 7
    • 34548684109 scopus 로고    scopus 로고
    • Etiologic classification of degenerative mitral valve disease: Barlow's disease and fibroelastic deficiency
    • A.C. Anyanwu, and D.H. Adams Etiologic classification of degenerative mitral valve disease: Barlow's disease and fibroelastic deficiency Semin Thorac Cardiovasc Surg 19 2007 90 96
    • (2007) Semin Thorac Cardiovasc Surg , vol.19 , pp. 90-96
    • Anyanwu, A.C.1    Adams, D.H.2
  • 9
    • 68249111128 scopus 로고    scopus 로고
    • Percutaneous mitral repair with the MitraClip system: Safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge Repair Study) cohort
    • T. Feldman, S. Kar, M. Rinaldi, P. Fail, J. Hermiller, and R. Smalling Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge Repair Study) cohort J Am Coll Cardiol 54 2009 686 694
    • (2009) J Am Coll Cardiol , vol.54 , pp. 686-694
    • Feldman, T.1    Kar, S.2    Rinaldi, M.3    Fail, P.4    Hermiller, J.5    Smalling, R.6
  • 10
    • 70449631494 scopus 로고    scopus 로고
    • Three-dimensional transoesophageal echocardiography in a patient undergoing percutaneous mitral valve repair using the edge-to-edge clip technique
    • M.J. Swaans, B.J. Van den Branden, J.A. Van der Heyden, M.C. Post, B.J. Rensing, and F.D. Eefting Three-dimensional transoesophageal echocardiography in a patient undergoing percutaneous mitral valve repair using the edge-to-edge clip technique Eur J Echocardiogr 10 2009 982 983
    • (2009) Eur J Echocardiogr , vol.10 , pp. 982-983
    • Swaans, M.J.1    Van Den Branden, B.J.2    Van Der Heyden, J.A.3    Post, M.C.4    Rensing, B.J.5    Eefting, F.D.6
  • 11
    • 0032897839 scopus 로고    scopus 로고
    • The hemodynamic effects of double-orifice valve repair for mitral regurgitation: A 3D computational model
    • F. Maisano, A. Redaelli, G. Pennati, R. Fumero, L. Torracca, and O. Alfieri The hemodynamic effects of double-orifice valve repair for mitral regurgitation: a 3D computational model Eur J Cardiothorac Surg 15 1999 419 425
    • (1999) Eur J Cardiothorac Surg , vol.15 , pp. 419-425
    • Maisano, F.1    Redaelli, A.2    Pennati, G.3    Fumero, R.4    Torracca, L.5    Alfieri, O.6
  • 12
    • 0035663304 scopus 로고    scopus 로고
    • A computational study of the hemodynamics after "edge-to-edge" mitral valve repair
    • A. Redaelli, G. Guadagni, R. Fumero, F. Maisano, and O. Alfieri A computational study of the hemodynamics after "edge-to-edge" mitral valve repair J Biomech Eng 123 2001 565 570
    • (2001) J Biomech Eng , vol.123 , pp. 565-570
    • Redaelli, A.1    Guadagni, G.2    Fumero, R.3    Maisano, F.4    Alfieri, O.5
  • 13
    • 67651153005 scopus 로고    scopus 로고
    • Hemodynamics of the mitral valve under edge-to-edge repair: An in vitro steady flow study
    • L. Shi, and Z. He Hemodynamics of the mitral valve under edge-to-edge repair: an in vitro steady flow study J Biomech Eng 2009 131 051010
    • (2009) J Biomech Eng , pp. 131
    • Shi, L.1    He, Z.2
  • 14
    • 77649241509 scopus 로고    scopus 로고
    • Reproducibility of proximal isovelocity surface area, vena contracta, and regurgitant jet area for assessment of mitral regurgitation severity
    • S. Biner, A. Rafique, F. Rafii, K. Tolstrup, O. Noorani, and T. Shiota Reproducibility of proximal isovelocity surface area, vena contracta, and regurgitant jet area for assessment of mitral regurgitation severity JACC Cardiovasc Imaging 3 2010 235 243
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 235-243
    • Biner, S.1    Rafique, A.2    Rafii, F.3    Tolstrup, K.4    Noorani, O.5    Shiota, T.6
  • 15
    • 72449123623 scopus 로고    scopus 로고
    • Quantification of mitral regurgitation using high pulse repetition frequency three-dimensional color Doppler
    • T.R. Skaug, T. Hergum, B.H. Amundsen, T. Skjaerpe, H. Torp, and B.O. Haugen Quantification of mitral regurgitation using high pulse repetition frequency three-dimensional color Doppler J Am Soc Echocardiogr 23 2010 1 8
    • (2010) J Am Soc Echocardiogr , vol.23 , pp. 1-8
    • Skaug, T.R.1    Hergum, T.2    Amundsen, B.H.3    Skjaerpe, T.4    Torp, H.5    Haugen, B.O.6
  • 16
    • 56549087880 scopus 로고    scopus 로고
    • Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta
    • B. Plicht, P. Kahlert, R. Goldwasser, R.A. Janosi, P. Hunold, and R. Erbel Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta J Am Soc Echocardiogr 21 2008 1337 1346
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 1337-1346
    • Plicht, B.1    Kahlert, P.2    Goldwasser, R.3    Janosi, R.A.4    Hunold, P.5    Erbel, R.6
  • 18
    • 0024566051 scopus 로고
    • Quantitative assessment of mitral regurgitation by Doppler color flow imaging: Angiographic and hemodynamic correlations
    • M.G. Spain, M.D. Smith, P.A. Grayburn, E.A. Harlamert, and A.N. DeMaria Quantitative assessment of mitral regurgitation by Doppler color flow imaging: angiographic and hemodynamic correlations J Am Coll Cardiol 13 1989 585 590
    • (1989) J Am Coll Cardiol , vol.13 , pp. 585-590
    • Spain, M.G.1    Smith, M.D.2    Grayburn, P.A.3    Harlamert, E.A.4    Demaria, A.N.5
  • 19
    • 33846950050 scopus 로고    scopus 로고
    • Mitral regurgitation in myocardial infarction complicated by heart failure, left ventricular dysfunction, or both: Prognostic significance and relation to ventricular size and function
    • M. Amigoni, A. Meris, J.J. Thune, D. Mangalat, H. Skali, and M. Bourgoun Mitral regurgitation in myocardial infarction complicated by heart failure, left ventricular dysfunction, or both: Prognostic significance and relation to ventricular size and function Eur Heart J 28 2007 326 333
    • (2007) Eur Heart J , vol.28 , pp. 326-333
    • Amigoni, M.1    Meris, A.2    Thune, J.J.3    Mangalat, D.4    Skali, H.5    Bourgoun, M.6
  • 20
    • 0026575678 scopus 로고
    • Influence of the Coanda effect on color Doppler jet area and color encoding. in vitro studies using color Doppler flow mapping
    • K. Chao, V.A. Moises, R. Shandas, T. Elkadi, D.J. Sahn, and R. Weintraub Influence of the Coanda effect on color Doppler jet area and color encoding. In vitro studies using color Doppler flow mapping Circulation 85 1992 333 341
    • (1992) Circulation , vol.85 , pp. 333-341
    • Chao, K.1    Moises, V.A.2    Shandas, R.3    Elkadi, T.4    Sahn, D.J.5    Weintraub, R.6
  • 21
    • 0026078437 scopus 로고
    • Effects of pressure and volume of the receiving chamber on the spatial distribution of regurgitant jets as imaged by color Doppler flow mapping. An in vitro study
    • B.C. Maciel, V.A. Moises, R. Shandas, I.A. Simpson, M. Beltran, and L. Valdes-Cruz Effects of pressure and volume of the receiving chamber on the spatial distribution of regurgitant jets as imaged by color Doppler flow mapping. An in vitro study Circulation 83 1991 605 613
    • (1991) Circulation , vol.83 , pp. 605-613
    • MacIel, B.C.1    Moises, V.A.2    Shandas, R.3    Simpson, I.A.4    Beltran, M.5    Valdes-Cruz, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.