메뉴 건너뛰기




Volumn 49, Issue 9, 2010, Pages 901-908

Fractal analysis of viscoelastic data with automated gel point location and its potential application in the investigation of therapeutically modified blood coagulation

Author keywords

Anti coagulant; Fractal dimension; Incipient clot; Rheometry

Indexed keywords


EID: 77956177149     PISSN: 00354511     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00397-010-0472-7     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 0037422847 scopus 로고    scopus 로고
    • The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration
    • Bossuyt P (2003) The STARD statement for reporting studies of diagnostic accuracy: explanation and elaboration. Ann Intern Med 138: 40-45.
    • (2003) Ann Intern Med , vol.138 , pp. 40-45
    • Bossuyt, P.1
  • 3
    • 0029583515 scopus 로고
    • Nonlinear viscoelasticity and thromboelastograph. 1. Studies on bovine plasma clots
    • Burghardt WR, Goldstick TK, Leneschmidt J, Kempka K (1995) Nonlinear viscoelasticity and thromboelastograph. 1. Studies on bovine plasma clots. Biorheology 32: 621-630.
    • (1995) Biorheology , vol.32 , pp. 621-630
    • Burghardt, W.R.1    Goldstick, T.K.2    Leneschmidt, J.3    Kempka, K.4
  • 4
    • 3743076841 scopus 로고
    • Linear viscoelasticity at the Gel Point of a cross-linking PDMS with imbalanced stoichiometry
    • Chambon F, Winter HH (1987) Linear viscoelasticity at the Gel Point of a cross-linking PDMS with imbalanced stoichiometry. J Rheol 31(8): 683-697.
    • (1987) J Rheol , vol.31 , Issue.8 , pp. 683-697
    • Chambon, F.1    Winter, H.H.2
  • 5
    • 37349016591 scopus 로고    scopus 로고
    • Rheometrical detection of incipient blood clot formation by Fourier transform mechanical spectroscopy
    • Evans PA, Hawkins K, Williams PR, Williams RL (2008a) Rheometrical detection of incipient blood clot formation by Fourier transform mechanical spectroscopy. J Non-Newton Fluid Mech 148: 122-127.
    • (2008) J Non-Newton Fluid Mech , vol.148 , pp. 122-127
    • Evans, P.A.1    Hawkins, K.2    Williams, P.R.3    Williams, R.L.4
  • 6
    • 42049090153 scopus 로고    scopus 로고
    • Studies of whole blood coagulation by oscillatory shear, thromboelastography and free oscillation rheometry
    • Evans PA, Hawkins K, Lawrence M, Williams PR, Williams RL (2008b) Studies of whole blood coagulation by oscillatory shear, thromboelastography and free oscillation rheometry. Clin Hemorheol Microcirc 38: 267-277.
    • (2008) Clin Hemorheol Microcirc , vol.38 , pp. 267-277
    • Evans, P.A.1    Hawkins, K.2    Lawrence, M.3    Williams, P.R.4    Williams, R.L.5
  • 8
    • 77956169533 scopus 로고    scopus 로고
    • Gel point and fractal microstructure of incipient blood clots are significant new markers of haemostasis for healthy and anticoagulated blood
    • doi:10.1182/blood-2010-02-269324
    • Evans PA, Hawkins K, Morris RHK, Thirumalai N, Munro R, Wakeman L, Lawrence M, Williams PR (2010) Gel point and fractal microstructure of incipient blood clots are significant new markers of haemostasis for healthy and anticoagulated blood. Blood. doi: 10. 1182/blood-2010-02-269324.
    • (2010) Blood
    • Munro, R.1    Wakeman, L.2    Lawrence, M.3    Williams, P.R.4
  • 9
    • 9344240973 scopus 로고
    • Thromboelastography: Physical and physiological aspects
    • A. L. Copley and C. Stainsby (Eds.), Oxford: Pergamon
    • Hartert H (1960) Thromboelastography: physical and physiological aspects. In: Copley AL, Stainsby C (eds) Flow properties of blood and other biological systems. Pergamon, Oxford, pp 86-198.
    • (1960) Flow Properties of Blood and Other Biological Systems , pp. 86-198
    • Hartert, H.1
  • 11
    • 0023962992 scopus 로고
    • Fourier transform mechanical spectroscopy of viscoelastic materials with transient structure
    • Holly EE, Venkataraman SK, Chambon F, Winter HH (1988) Fourier transform mechanical spectroscopy of viscoelastic materials with transient structure. J Non-Newton Fluid Mech 27: 17-26.
    • (1988) J Non-Newton Fluid Mech , vol.27 , pp. 17-26
    • Holly, E.E.1    Venkataraman, S.K.2    Chambon, F.3    Winter, H.H.4
  • 12
    • 0027617896 scopus 로고
    • Viscoelastic behaviour at the thermal sol-gel transition of gelatin
    • Hsu SH, Jamieson AM (1993) Viscoelastic behaviour at the thermal sol-gel transition of gelatin. Polymer 34: 2602-2608.
    • (1993) Polymer , vol.34 , pp. 2602-2608
    • Hsu, S.H.1    Jamieson, A.M.2
  • 13
    • 77956179395 scopus 로고    scopus 로고
    • A comparison of three months of anticoagulation with extended anticoagulation for a first episode of idiopathic venous thromboembolism
    • Kearon C et al (2001) A comparison of three months of anticoagulation with extended anticoagulation for a first episode of idiopathic venous thromboembolism. Chest 119: 1S-370S.
    • (2001) Chest , vol.119 , pp. 1-370
    • Kearon, C.1
  • 14
    • 0019161808 scopus 로고
    • Monitoring heparin therapy with thromboelastography and activated partial thromboplastin time
    • Lee BY, Taha S, Trainor FS, Kavner D, McCann WJ (1980) Monitoring heparin therapy with thromboelastography and activated partial thromboplastin time. World J Surg 4: 323-330.
    • (1980) World J Surg , vol.4 , pp. 323-330
    • Lee, B.Y.1    Taha, S.2    Trainor, F.S.3    Kavner, D.4    McCann, W.J.5
  • 16
    • 0000511699 scopus 로고
    • Concentration dependence of the critical viscoelastic properties of gelatin at the gel
    • Michon C, Cuvelier G, Launay B (1993) Concentration dependence of the critical viscoelastic properties of gelatin at the gel. Rheol Acta 32: 94-103.
    • (1993) Rheol Acta , vol.32 , pp. 94-103
    • Michon, C.1    Cuvelier, G.2    Launay, B.3
  • 17
    • 0012903316 scopus 로고
    • Screening effect on viscoelasticity near the gel point
    • Muthukumar M (1989) Screening effect on viscoelasticity near the gel point. Macromol 22: 4658-4660.
    • (1989) Macromol , vol.22 , pp. 4658-4660
    • Muthukumar, M.1
  • 18
    • 1542698184 scopus 로고
    • Fractal dimension of a cross-linking polymer at the gel point
    • Muthukumar M, Winter HH (1986) Fractal dimension of a cross-linking polymer at the gel point. Macromol 19: 1284-1285.
    • (1986) Macromol , vol.19 , pp. 1284-1285
    • Muthukumar, M.1    Winter, H.H.2
  • 19
    • 0026629166 scopus 로고
    • Fibrin clots obtained from plasma containing heparin show a higher sensitivity to t-PA-induced lysis
    • Nenci GG, Parise P, Morini M, Rossini A, Agnelli G (1992) Fibrin clots obtained from plasma containing heparin show a higher sensitivity to t-PA-induced lysis. Blood Coagul Fibrinolysis 3: 279-285.
    • (1992) Blood Coagul Fibrinolysis , vol.3 , pp. 279-285
    • Nenci, G.G.1    Parise, P.2    Morini, M.3    Rossini, A.4    Agnelli, G.5
  • 20
    • 0036711275 scopus 로고    scopus 로고
    • Monitoring of hirudin therapy with the thromboelastograph
    • Pivalizza EG (2002) Monitoring of hirudin therapy with the thromboelastograph. J Clin Anesth 14: 456-458.
    • (2002) J Clin Anesth , vol.14 , pp. 456-458
    • Pivalizza, E.G.1
  • 21
    • 37349035030 scopus 로고
    • Thromboelastography of Newtonian fluids
    • Scott Blair GW, Burnett J (1968) Thromboelastography of Newtonian fluids. Biorheology 5: 177.
    • (1968) Biorheology , vol.5 , pp. 177
    • Scott Blair, G.W.1    Burnett, J.2
  • 22
    • 2942653140 scopus 로고    scopus 로고
    • Determination of the maximum gelation temperature in gelatin gels
    • Tosh SM, Marangoni AG (2004) Determination of the maximum gelation temperature in gelatin gels. Appl Phys Lett 84: 4242-4244.
    • (2004) Appl Phys Lett , vol.84 , pp. 4242-4244
    • Tosh, S.M.1    Marangoni, A.G.2
  • 23
    • 9644260704 scopus 로고    scopus 로고
    • The mechanical properties of fibrin for basic scientists and clinicians
    • Weisel JW (2004) The mechanical properties of fibrin for basic scientists and clinicians. Biophys Chemist 112: 267-76.
    • (2004) Biophys Chemist , vol.112 , pp. 267-276
    • Weisel, J.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.