메뉴 건너뛰기




Volumn 10, Issue 9, 2010, Pages

Vertebral body fracture after anterolateral instrumentation and interbody fusion in two osteoporotic patients

Author keywords

Complication; Interbody fusion; Vertebral fracture; XLIF

Indexed keywords

AGED; ANALGESIA; ARTICLE; BODY MASS; CASE REPORT; CONSERVATIVE TREATMENT; DECOMPRESSION SURGERY; DIAGNOSTIC IMAGING; DISEASE SEVERITY; FEMALE; HUMAN; INSTRUMENTATION; KYPHOPLASTY; LOW BACK PAIN; OSTEOPOROSIS; PEDICLE SCREW; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; SPINE FUSION; VERTEBRA BODY; VERTEBRA FRACTURE;

EID: 77956167645     PISSN: 15299430     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.spinee.2010.07.007     Document Type: Article
Times cited : (49)

References (19)
  • 1
    • 33745649897 scopus 로고    scopus 로고
    • Extreme lateral interbody fusion (XLIF): A novel surgical technique for anterior lumbar interbody fusion
    • B.M. Ozgur, H.E. Aryan, L. Pimenta, and W.R. Taylor Extreme lateral interbody fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion Spine J 6 2006 435 443
    • (2006) Spine J , vol.6 , pp. 435-443
    • Ozgur, B.M.1    Aryan, H.E.2    Pimenta, L.3    Taylor, W.R.4
  • 2
    • 77956136102 scopus 로고    scopus 로고
    • Biomechanical evaluation of lumbar constructs using eXtreme lateral interbody fusion (XLIF®)
    • Abstract presented at Bahamas, July 2007
    • Bess RS, Bachus KN, Vance R, et al. Biomechanical evaluation of lumbar constructs using eXtreme lateral interbody fusion (XLIF®). 2007. Abstract presented at International Meeting on Advanced Spine Techniques, Paradise Island, Bahamas, July 2007.
    • (2007) International Meeting on Advanced Spine Techniques, Paradise Island
    • Bess, R.S.1    Bachus, K.N.2    Vance, R.3
  • 3
    • 0031024523 scopus 로고    scopus 로고
    • Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits
    • K. Kaneda, H. Taneichi, and K. Abumi Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits J Bone Joint Surg Am 79 1997 69 83
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 69-83
    • Kaneda, K.1    Taneichi, H.2    Abumi, K.3
  • 4
    • 0030924248 scopus 로고    scopus 로고
    • Four year experience with the AO anterior thoracolumbar locking plate
    • J.S. Thalgott, M.B. Kabins, and M. Timlin Four year experience with the AO anterior thoracolumbar locking plate Spinal Cord 35 1997 286 291
    • (1997) Spinal Cord , vol.35 , pp. 286-291
    • Thalgott, J.S.1    Kabins, M.B.2    Timlin, M.3
  • 5
    • 30944445760 scopus 로고    scopus 로고
    • Retroperitoneal approach for lumbar interbody fusion with anterolateral instrumentation for treatment of spondylolisthesis and degenerative foraminal stenosis
    • J.D. Klopfenstein, L.J. Kim, I. Feiz-Erfan, and C.A. Dickman Retroperitoneal approach for lumbar interbody fusion with anterolateral instrumentation for treatment of spondylolisthesis and degenerative foraminal stenosis Surg Neurol 65 2006 111 116 discussion 116
    • (2006) Surg Neurol , vol.65 , pp. 111-116
    • Klopfenstein, J.D.1    Kim, L.J.2    Feiz-Erfan, I.3    Dickman, C.A.4
  • 6
    • 35948937615 scopus 로고    scopus 로고
    • Technique and clinical results of minimally invasive reconstruction and stabilization of the thoracic and thoracolumbar spine with expandable cages and ventrolateral plate fixation
    • K.M. Scheufler Technique and clinical results of minimally invasive reconstruction and stabilization of the thoracic and thoracolumbar spine with expandable cages and ventrolateral plate fixation Neurosurgery 61 2007 798 808 discussion 808-9
    • (2007) Neurosurgery , vol.61 , pp. 798-808
    • Scheufler, K.M.1
  • 7
    • 34250673178 scopus 로고    scopus 로고
    • Stand-alone anterior lumbar discectomy and fusion with plate: Initial experience
    • H.E. Aryan, D.C. Lu, F.L. Acosta Jr., and C.P. Ames Stand-alone anterior lumbar discectomy and fusion with plate: initial experience Surg Neurol 68 2007 7 13 discussion 13
    • (2007) Surg Neurol , vol.68 , pp. 7-13
    • Aryan, H.E.1    Lu, D.C.2    Acosta Jr., F.L.3    Ames, C.P.4
  • 8
    • 0014463475 scopus 로고
    • The relative contribution of trabecular and cortical bone to the strength of human lumbar vertebrae
    • S.D. Rockoff, E. Sweet, and J. Bleustein The relative contribution of trabecular and cortical bone to the strength of human lumbar vertebrae Calcif Tissue Res 3 1969 163 175
    • (1969) Calcif Tissue Res , vol.3 , pp. 163-175
    • Rockoff, S.D.1    Sweet, E.2    Bleustein, J.3
  • 9
    • 0034192830 scopus 로고    scopus 로고
    • Effect of implant design and endplate preparation on the compressive strength of interbody fusion constructs
    • T. Steffen, A. Tsantrizos, and M. Aebi Effect of implant design and endplate preparation on the compressive strength of interbody fusion constructs Spine 25 2000 1077 1084
    • (2000) Spine , vol.25 , pp. 1077-1084
    • Steffen, T.1    Tsantrizos, A.2    Aebi, M.3
  • 10
    • 0026548045 scopus 로고
    • Isolated L4-L5 fusions using the variable screw placement system: Unilateral versus bilateral
    • M.B. Kabins, J.N. Weinstein, and K.F. Spratt Isolated L4-L5 fusions using the variable screw placement system: unilateral versus bilateral J Spinal Disord 5 1992 39 49
    • (1992) J Spinal Disord , vol.5 , pp. 39-49
    • Kabins, M.B.1    Weinstein, J.N.2    Spratt, K.F.3
  • 11
    • 0343526849 scopus 로고    scopus 로고
    • Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion
    • K.S. Suk, H.M. Lee, N.H. Kim, and J.W. Ha Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion Spine (Phila Pa 1976) 25 2000 1843 1847
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 1843-1847
    • Suk, K.S.1    Lee, H.M.2    Kim, N.H.3    Ha, J.W.4
  • 12
    • 0036791682 scopus 로고    scopus 로고
    • Load transfer mechanisms in cylindrical interbody cage constructs
    • W.J. Palm IV, W.S. Rosenberg, and T.M. Keaveny Load transfer mechanisms in cylindrical interbody cage constructs Spine 27 2002 2101 2107
    • (2002) Spine , vol.27 , pp. 2101-2107
    • Palm, W.J.I.V.1    Rosenberg, W.S.2    Keaveny, T.M.3
  • 13
    • 46749103284 scopus 로고    scopus 로고
    • Angular stable anterior plating following thoracolumbar corpectomy reveals superior segmental stability compared to conventional polyaxial plate fixation
    • A.C. Disch, C. Knop, and K.D. Schaser Angular stable anterior plating following thoracolumbar corpectomy reveals superior segmental stability compared to conventional polyaxial plate fixation Spine 33 2008 1429 1437
    • (2008) Spine , vol.33 , pp. 1429-1437
    • Disch, A.C.1    Knop, C.2    Schaser, K.D.3
  • 14
    • 0028034777 scopus 로고
    • Effects of bone mineral density on pedicle screw fixation
    • T.L. Halvorson, L.A. Kelley, and K.A. Thomas Effects of bone mineral density on pedicle screw fixation Spine 19 1994 2415 2420
    • (1994) Spine , vol.19 , pp. 2415-2420
    • Halvorson, T.L.1    Kelley, L.A.2    Thomas, K.A.3
  • 15
    • 34247637260 scopus 로고    scopus 로고
    • Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: Biomechanical analysis of pedicle fixation strength
    • D.J. Burval, R.F. McLain, R. Milks, and S. Inceoglu Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength Spine 32 2007 1077 1083
    • (2007) Spine , vol.32 , pp. 1077-1083
    • Burval, D.J.1    McLain, R.F.2    Milks, R.3    Inceoglu, S.4
  • 16
    • 3342928907 scopus 로고    scopus 로고
    • Biomechanical study of pedicle screw fixation in severely osteoporotic bone
    • S.D. Cook, S.L. Salkeld, and T. Stanley Biomechanical study of pedicle screw fixation in severely osteoporotic bone Spine J 4 2004 402 408
    • (2004) Spine J , vol.4 , pp. 402-408
    • Cook, S.D.1    Salkeld, S.L.2    Stanley, T.3
  • 17
    • 0025153831 scopus 로고
    • Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires
    • J.D. Coe, K.E. Warden, M.A. Herzig, and P.C. McAfee Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires Spine (Phila Pa 1976) 15 1990 902 907
    • (1990) Spine (Phila Pa 1976) , vol.15 , pp. 902-907
    • Coe, J.D.1    Warden, K.E.2    Herzig, M.A.3    McAfee, P.C.4
  • 18
    • 0027378841 scopus 로고
    • Relation of vertebral bone screw axial pullout strength to quantitative computed tomographic trabecular bone mineral content
    • S.G. Gilbert, P.C. Johns, D.C. Chow, and R.C. Black Relation of vertebral bone screw axial pullout strength to quantitative computed tomographic trabecular bone mineral content J Spinal Disord 6 1993 513 521
    • (1993) J Spinal Disord , vol.6 , pp. 513-521
    • Gilbert, S.G.1    Johns, P.C.2    Chow, D.C.3    Black, R.C.4
  • 19
    • 45149115405 scopus 로고    scopus 로고
    • Adjacent-level vertebral body fractures after expandable cage reconstruction
    • D. Chou, D.C. Lu, P. Weinstein, and C.P. Ames Adjacent-level vertebral body fractures after expandable cage reconstruction J Neurosurg Spine 8 2008 584 588
    • (2008) J Neurosurg Spine , vol.8 , pp. 584-588
    • Chou, D.1    Lu, D.C.2    Weinstein, P.3    Ames, C.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.