-
1
-
-
35848967011
-
Promise and challenges of bioabsorbable stents
-
DOI 10.1002/ccd.21176
-
Waksman R. Promise and Challenges of Bioabsorbable Stents. Catheter Cardiovasc Interv 2007;70:407-414. (Pubitemid 350194989)
-
(2007)
Catheterization and Cardiovascular Interventions
, vol.70
, Issue.3
, pp. 407-414
-
-
Waksman, R.1
-
2
-
-
12144250767
-
Preliminary results after application of absorbable metal stents in patients with critical limb ischemia
-
DOI 10.1583/04-1349R.1
-
Peeters P, Bosiers M, Verbist J, Deloose K, Heublein B. Preliminary results after application of absorbable metal stents in patients with critical limb ischemia. J Endovasc Ther 2005;12:1-5. (Pubitemid 40229382)
-
(2005)
Journal of Endovascular Therapy
, vol.12
, Issue.1
, pp. 1-5
-
-
Peeters, P.1
Bosiers, M.2
Verbist, J.3
Deloose, K.4
Heublein, B.5
-
3
-
-
35148829522
-
Coronary bioabsorbable magnesium stent: 15-Month intravascular ultrasound and optical coherence tomography findings
-
DOI 10.1093/eurheartj/ehm119
-
Barlis P, Tanigawa J, Di Mario C. Coronary bioabsorbable magnesium stent: 15-month intravascular ultrasound and optical coherence tomography findings. Eur Heart J 2007;28:2319. (Pubitemid 47537770)
-
(2007)
European Heart Journal
, vol.28
, Issue.19
, pp. 2319
-
-
Barlis, P.1
Tanigawa, J.2
Di, M.C.3
-
4
-
-
53449099699
-
Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries
-
Slottow TL, Pakala R, Okabe T, Hellinga D, Lovec RJ, Tio FO, Bui AB, Waksman R. Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries. Cardiovasc Revasc Med 2008;9:248-254.
-
(2008)
Cardiovasc Revasc Med
, vol.9
, pp. 248-254
-
-
Slottow, T.L.1
Pakala, R.2
Okabe, T.3
Hellinga, D.4
Lovec, R.J.5
Tio, F.O.6
Bui, A.B.7
Waksman, R.8
-
5
-
-
28844455504
-
First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
-
DOI 10.1002/ccd.20520
-
Zartner P, Cesnjevar R, Singer H, Weyand M. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby. Catheter Cardiovasc Interv 2005;66:590-594. (Pubitemid 41779033)
-
(2005)
Catheterization and Cardiovascular Interventions
, vol.66
, Issue.4
, pp. 590-594
-
-
Zartner, P.1
Cesnjevar, R.2
Singer, H.3
Weyand, M.4
-
6
-
-
33847354676
-
First biodegradable metal stent in a child with congenital heart disease: Evaluation of macro and histopathology
-
DOI 10.1002/ccd.20828
-
Zartner P, Buettner M, Singer H, Sigler M. First biodegradable metal stent in a child with congenital heart disease: evaluation of macro and histopathology. Catheter Cardiovasc Interv 2007;69:443-446. (Pubitemid 46339290)
-
(2007)
Catheterization and Cardiovascular Interventions
, vol.69
, Issue.3
, pp. 443-446
-
-
Zartner, P.1
Buettner, M.2
Singer, H.3
Sigler, M.4
-
7
-
-
33646265009
-
Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn
-
Schranz D, Zartner P, Michel-Behnke I, Akintürk H. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn. Catheter Cardiovasc Interv 2006;67:671-673.
-
(2006)
Catheter Cardiovasc Interv
, vol.67
, pp. 671-673
-
-
Schranz, D.1
Zartner, P.2
Michel-Behnke, I.3
Akintürk, H.4
-
8
-
-
9244220627
-
Drug-eluting bioabsorbable magnesium stent
-
DOI 10.1111/j.1540-8183.2004.04081.x
-
Di Mario C, Griffiths H, Goktekin O, Peeters N, Verbist J, Bosiers M, Deloose K, Heublein B, Rohde R, Kasese V, Ilsley C, Erbel R. Drug-eluting bioabsorbable magnesium stent. J Interv Cardiol 2004;17:391-395. (Pubitemid 39552594)
-
(2004)
Journal of Interventional Cardiology
, vol.17
, Issue.6
, pp. 391-395
-
-
Di, M.C.1
Griffiths, H.2
Goktekin, O.3
Peeters, N.4
Verbist, J.5
Bosiers, M.6
Deloose, K.7
Heublein, B.8
Rohde, R.9
Kasese, V.10
Ilsley, C.11
Erbel, R.12
-
9
-
-
33646262493
-
First clinical application of absorbable metal stents in the treatment of critical limb ischemia: 12- month results
-
Bosiers M, Deloose K, Verbist J, Peeters P. First clinical application of absorbable metal stents in the treatment of critical limb ischemia: 12- month results. Vasc Dis Manage 2005;2:86-91.
-
(2005)
Vasc Dis Manage
, vol.2
, pp. 86-91
-
-
Bosiers, M.1
Deloose, K.2
Verbist, J.3
Peeters, P.4
-
10
-
-
34249655184
-
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial
-
PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators
-
Erbel R, Di Mario C, Bartunek J, Bonnier J, de Bruyne B, Eberli FR, Erne P, Haude M, Heublein B, Horrigan M, Ilsley C, Böse D, Koolen J, Lüscher TF, Weissman N, Waksman R; PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. Lancet 2007;369:1869-1875.
-
(2007)
Lancet
, vol.369
, pp. 1869-1875
-
-
Erbel, R.1
Di Mario, C.2
Bartunek, J.3
Bonnier, J.4
De Bruyne, B.5
Eberli, F.R.6
Erne, P.7
Haude, M.8
Heublein, B.9
Horrigan, M.10
Ilsley, C.11
Böse, D.12
Koolen, J.13
Lüscher, T.F.14
Weissman, N.15
Waksman, R.16
-
11
-
-
33745661000
-
Images in cardiology: Absorbable metal stent in human coronary arteries: Imaging with intravascular ultrasound
-
DOI 10.1136/hrt.2005.076562
-
Bose D, Eggebrecht H, Erbel R. Absorbable metal stent in human coronary arteries: imaging with intravascular ultrasound. Heart 2006;92:892. (Pubitemid 43974046)
-
(2006)
Heart
, vol.92
, Issue.7
, pp. 892
-
-
Bose, D.1
Eggebrecht, H.2
Erbel, R.3
-
12
-
-
0038486163
-
Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
-
Heublein B, Rohde R, Kaese V, Niemeyer M, Hartung W, Haverich A. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? Heart 2003;89:651-656.
-
(2003)
Heart
, vol.89
, pp. 651-656
-
-
Heublein, B.1
Rohde, R.2
Kaese, V.3
Niemeyer, M.4
Hartung, W.5
Haverich, A.6
-
13
-
-
67349090919
-
AMS INSIGHT - Absorbable metal stent implantation for treatment of below-the-knee critical limb ischemia: 6-month analysis
-
AMS INSIGHT Investigators
-
Bosiers M, Peeters P, D'Archambeau O, Hendriks J, Pilger E, Düber C, Zeller T, Gussmann A, Lohle PN, Minar E, Scheinert D, Hausegger K, Schulte KL, Verbist J, Deloose K, Lammer J; AMS INSIGHT Investigators. AMS INSIGHT - absorbable metal stent implantation for treatment of below-the-knee critical limb ischemia: 6-month analysis. Cardiovasc Intervent Radiol 2009;32:424-435.
-
(2009)
Cardiovasc Intervent Radiol
, vol.32
, pp. 424-435
-
-
Bosiers, M.1
Peeters, P.2
D'Archambeau, O.3
Hendriks, J.4
Pilger, E.5
Düber, C.6
Zeller, T.7
Gussmann, A.8
Lohle, P.N.9
Minar, E.10
Scheinert, D.11
Hausegger, K.12
Schulte, K.L.13
Verbist, J.14
Deloose, K.15
Lammer, J.16
-
14
-
-
33749046079
-
Will absorbable metal stent technology change our practice?
-
Torino
-
Bosiers M, Deloose K, Verbist J, Peeters P. Will absorbable metal stent technology change our practice? J Cardiovasc Surg (Torino) 2006;47:393-397.
-
(2006)
J Cardiovasc Surg
, vol.47
, pp. 393-397
-
-
Bosiers, M.1
Deloose, K.2
Verbist, J.3
Peeters, P.4
-
15
-
-
64749089047
-
Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries
-
PROGRESS-AMS (Clinical Performance Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators
-
Waksman R, Erbel R, Di Mario C, Bartunek J, de Bruyne B, Eberli FR, Erne P, Haude M, Horrigan M, Ilsley C, Böse D, Bonnier H, Koolen J, Lüscher TF, Weissman NJ; PROGRESS-AMS (Clinical Performance Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries. JACC Cardiovasc Interv 2009;2:312-320.
-
(2009)
JACC Cardiovasc Interv
, vol.2
, pp. 312-320
-
-
Waksman, R.1
Erbel, R.2
Di Mario, C.3
Bartunek, J.4
De Bruyne, B.5
Eberli, F.R.6
Erne, P.7
Haude, M.8
Horrigan, M.9
Ilsley, C.10
Böse, D.11
Bonnier, H.12
Koolen, J.13
Lüscher, T.F.14
Weissman, N.J.15
-
16
-
-
63049091561
-
Initial evidence for the return of coronary vasoreactivity following the absorption of bioabsorbable magnesium alloy coronary stents
-
Ghimire G, Spiro J, Kharbanda R, Roughton M, Barlis P, Mason M, Ilsley C, Di Mario C, Erbel R, Waksman R, Dalby M. Initial evidence for the return of coronary vasoreactivity following the absorption of bioabsorbable magnesium alloy coronary stents. EuroIntervention 2009;4:481-484.
-
(2009)
EuroIntervention
, vol.4
, pp. 481-484
-
-
Ghimire, G.1
Spiro, J.2
Kharbanda, R.3
Roughton, M.4
Barlis, P.5
Mason, M.6
Ilsley, C.7
Di Mario, C.8
Erbel, R.9
Waksman, R.10
Dalby, M.11
|