메뉴 건너뛰기




Volumn 5, Issue SUPPL. F, 2009, Pages

Current state of the absorbable metallic (magnesium) stent

Author keywords

[No Author keywords available]

Indexed keywords

CHROMIUM; COBALT; MAGNESIUM; STAINLESS STEEL;

EID: 77956147633     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/eijv5ifa16     Document Type: Review
Times cited : (25)

References (16)
  • 1
    • 35848967011 scopus 로고    scopus 로고
    • Promise and challenges of bioabsorbable stents
    • DOI 10.1002/ccd.21176
    • Waksman R. Promise and Challenges of Bioabsorbable Stents. Catheter Cardiovasc Interv 2007;70:407-414. (Pubitemid 350194989)
    • (2007) Catheterization and Cardiovascular Interventions , vol.70 , Issue.3 , pp. 407-414
    • Waksman, R.1
  • 2
    • 12144250767 scopus 로고    scopus 로고
    • Preliminary results after application of absorbable metal stents in patients with critical limb ischemia
    • DOI 10.1583/04-1349R.1
    • Peeters P, Bosiers M, Verbist J, Deloose K, Heublein B. Preliminary results after application of absorbable metal stents in patients with critical limb ischemia. J Endovasc Ther 2005;12:1-5. (Pubitemid 40229382)
    • (2005) Journal of Endovascular Therapy , vol.12 , Issue.1 , pp. 1-5
    • Peeters, P.1    Bosiers, M.2    Verbist, J.3    Deloose, K.4    Heublein, B.5
  • 3
    • 35148829522 scopus 로고    scopus 로고
    • Coronary bioabsorbable magnesium stent: 15-Month intravascular ultrasound and optical coherence tomography findings
    • DOI 10.1093/eurheartj/ehm119
    • Barlis P, Tanigawa J, Di Mario C. Coronary bioabsorbable magnesium stent: 15-month intravascular ultrasound and optical coherence tomography findings. Eur Heart J 2007;28:2319. (Pubitemid 47537770)
    • (2007) European Heart Journal , vol.28 , Issue.19 , pp. 2319
    • Barlis, P.1    Tanigawa, J.2    Di, M.C.3
  • 4
    • 53449099699 scopus 로고    scopus 로고
    • Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries
    • Slottow TL, Pakala R, Okabe T, Hellinga D, Lovec RJ, Tio FO, Bui AB, Waksman R. Optical coherence tomography and intravascular ultrasound imaging of bioabsorbable magnesium stent degradation in porcine coronary arteries. Cardiovasc Revasc Med 2008;9:248-254.
    • (2008) Cardiovasc Revasc Med , vol.9 , pp. 248-254
    • Slottow, T.L.1    Pakala, R.2    Okabe, T.3    Hellinga, D.4    Lovec, R.J.5    Tio, F.O.6    Bui, A.B.7    Waksman, R.8
  • 5
    • 28844455504 scopus 로고    scopus 로고
    • First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
    • DOI 10.1002/ccd.20520
    • Zartner P, Cesnjevar R, Singer H, Weyand M. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby. Catheter Cardiovasc Interv 2005;66:590-594. (Pubitemid 41779033)
    • (2005) Catheterization and Cardiovascular Interventions , vol.66 , Issue.4 , pp. 590-594
    • Zartner, P.1    Cesnjevar, R.2    Singer, H.3    Weyand, M.4
  • 6
    • 33847354676 scopus 로고    scopus 로고
    • First biodegradable metal stent in a child with congenital heart disease: Evaluation of macro and histopathology
    • DOI 10.1002/ccd.20828
    • Zartner P, Buettner M, Singer H, Sigler M. First biodegradable metal stent in a child with congenital heart disease: evaluation of macro and histopathology. Catheter Cardiovasc Interv 2007;69:443-446. (Pubitemid 46339290)
    • (2007) Catheterization and Cardiovascular Interventions , vol.69 , Issue.3 , pp. 443-446
    • Zartner, P.1    Buettner, M.2    Singer, H.3    Sigler, M.4
  • 7
    • 33646265009 scopus 로고    scopus 로고
    • Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn
    • Schranz D, Zartner P, Michel-Behnke I, Akintürk H. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn. Catheter Cardiovasc Interv 2006;67:671-673.
    • (2006) Catheter Cardiovasc Interv , vol.67 , pp. 671-673
    • Schranz, D.1    Zartner, P.2    Michel-Behnke, I.3    Akintürk, H.4
  • 9
    • 33646262493 scopus 로고    scopus 로고
    • First clinical application of absorbable metal stents in the treatment of critical limb ischemia: 12- month results
    • Bosiers M, Deloose K, Verbist J, Peeters P. First clinical application of absorbable metal stents in the treatment of critical limb ischemia: 12- month results. Vasc Dis Manage 2005;2:86-91.
    • (2005) Vasc Dis Manage , vol.2 , pp. 86-91
    • Bosiers, M.1    Deloose, K.2    Verbist, J.3    Peeters, P.4
  • 10
    • 34249655184 scopus 로고    scopus 로고
    • Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial
    • PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators
    • Erbel R, Di Mario C, Bartunek J, Bonnier J, de Bruyne B, Eberli FR, Erne P, Haude M, Heublein B, Horrigan M, Ilsley C, Böse D, Koolen J, Lüscher TF, Weissman N, Waksman R; PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. Lancet 2007;369:1869-1875.
    • (2007) Lancet , vol.369 , pp. 1869-1875
    • Erbel, R.1    Di Mario, C.2    Bartunek, J.3    Bonnier, J.4    De Bruyne, B.5    Eberli, F.R.6    Erne, P.7    Haude, M.8    Heublein, B.9    Horrigan, M.10    Ilsley, C.11    Böse, D.12    Koolen, J.13    Lüscher, T.F.14    Weissman, N.15    Waksman, R.16
  • 11
    • 33745661000 scopus 로고    scopus 로고
    • Images in cardiology: Absorbable metal stent in human coronary arteries: Imaging with intravascular ultrasound
    • DOI 10.1136/hrt.2005.076562
    • Bose D, Eggebrecht H, Erbel R. Absorbable metal stent in human coronary arteries: imaging with intravascular ultrasound. Heart 2006;92:892. (Pubitemid 43974046)
    • (2006) Heart , vol.92 , Issue.7 , pp. 892
    • Bose, D.1    Eggebrecht, H.2    Erbel, R.3
  • 12
    • 0038486163 scopus 로고    scopus 로고
    • Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
    • Heublein B, Rohde R, Kaese V, Niemeyer M, Hartung W, Haverich A. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? Heart 2003;89:651-656.
    • (2003) Heart , vol.89 , pp. 651-656
    • Heublein, B.1    Rohde, R.2    Kaese, V.3    Niemeyer, M.4    Hartung, W.5    Haverich, A.6
  • 14
    • 33749046079 scopus 로고    scopus 로고
    • Will absorbable metal stent technology change our practice?
    • Torino
    • Bosiers M, Deloose K, Verbist J, Peeters P. Will absorbable metal stent technology change our practice? J Cardiovasc Surg (Torino) 2006;47:393-397.
    • (2006) J Cardiovasc Surg , vol.47 , pp. 393-397
    • Bosiers, M.1    Deloose, K.2    Verbist, J.3    Peeters, P.4
  • 15
    • 64749089047 scopus 로고    scopus 로고
    • Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries
    • PROGRESS-AMS (Clinical Performance Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators
    • Waksman R, Erbel R, Di Mario C, Bartunek J, de Bruyne B, Eberli FR, Erne P, Haude M, Horrigan M, Ilsley C, Böse D, Bonnier H, Koolen J, Lüscher TF, Weissman NJ; PROGRESS-AMS (Clinical Performance Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries. JACC Cardiovasc Interv 2009;2:312-320.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 312-320
    • Waksman, R.1    Erbel, R.2    Di Mario, C.3    Bartunek, J.4    De Bruyne, B.5    Eberli, F.R.6    Erne, P.7    Haude, M.8    Horrigan, M.9    Ilsley, C.10    Böse, D.11    Bonnier, H.12    Koolen, J.13    Lüscher, T.F.14    Weissman, N.J.15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.