메뉴 건너뛰기




Volumn 483, Issue 1, 2010, Pages 28-31

Dual-frequency steady-state visual evoked potential for brain computer interface

Author keywords

Brain computer interface; Electroencephalography (EEG); Steady state visual evoked potential; Symmetric harmonic phenomenon

Indexed keywords

ADULT; ARTICLE; BRAIN COMPUTER INTERFACE; CLINICAL ARTICLE; ELECTROENCEPHALOGRAPHY; EVOKED VISUAL RESPONSE; HUMAN; LIGHT EMITTING DIODE; PRIORITY JOURNAL; RECOGNITION; STEADY STATE VISUAL EVOKED POTENTIAL; VISUAL STIMULATION;

EID: 77956120545     PISSN: 03043940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neulet.2010.07.043     Document Type: Article
Times cited : (80)

References (20)
  • 2
    • 70349773464 scopus 로고    scopus 로고
    • An online multi-channel SSVEP-based brain-computer interface using a canonical correlation analysis method
    • Bin G.Y., Gao X.R., Yan Z., Hong B., Gao S.K. An online multi-channel SSVEP-based brain-computer interface using a canonical correlation analysis method. Journal of Neural Engineering 2009, 6:046002.
    • (2009) Journal of Neural Engineering , vol.6 , pp. 046002
    • Bin, G.Y.1    Gao, X.R.2    Yan, Z.3    Hong, B.4    Gao, S.K.5
  • 5
    • 0023756085 scopus 로고
    • Talking off the top of your head: toward a mental prosthesis utilizing event-related potentials
    • Farwell L.A., Donchin E. Talking off the top of your head: toward a mental prosthesis utilizing event-related potentials. Electroencephalography and Clinical Neurophysiology 1988, 70:510-523.
    • (1988) Electroencephalography and Clinical Neurophysiology , vol.70 , pp. 510-523
    • Farwell, L.A.1    Donchin, E.2
  • 8
    • 23344447270 scopus 로고    scopus 로고
    • Visual evoked potential actuated brain computer interface: a brain-actuated cursor system
    • Lee P.L., Wu C.H., Hsieh J.C., Wu Y.T. Visual evoked potential actuated brain computer interface: a brain-actuated cursor system. Electronics Letters 2005, 41:832-834.
    • (2005) Electronics Letters , vol.41 , pp. 832-834
    • Lee, P.L.1    Wu, C.H.2    Hsieh, J.C.3    Wu, Y.T.4
  • 13
    • 28444496378 scopus 로고    scopus 로고
    • Steady-state visual evoked potential (SSVEP)-based communication: impact of harmonic frequency components
    • Müller-Putz G.R., Scherer R., Brauneis C., Pfurtscheller G. Steady-state visual evoked potential (SSVEP)-based communication: impact of harmonic frequency components. Journal of Neural Engineering 2005, 2:123-130.
    • (2005) Journal of Neural Engineering , vol.2 , pp. 123-130
    • Müller-Putz, G.R.1    Scherer, R.2    Brauneis, C.3    Pfurtscheller, G.4
  • 14
    • 33644778869 scopus 로고    scopus 로고
    • P300-based brain computer interface: reliability and performance in healthy and paralysed participants
    • Piccione F., Giorgi F., Tonin P. P300-based brain computer interface: reliability and performance in healthy and paralysed participants. Clinical Neurophysiology 2006, 117:531-537.
    • (2006) Clinical Neurophysiology , vol.117 , pp. 531-537
    • Piccione, F.1    Giorgi, F.2    Tonin, P.3
  • 16
    • 33746413926 scopus 로고    scopus 로고
    • Brain-computer interfaces for 1-D and 2-D cursor control: designs using volitional control of the EEG spectrum or steady-state visual evoked potentials
    • Trejo L.J., Rosipal R., Matthews B. Brain-computer interfaces for 1-D and 2-D cursor control: designs using volitional control of the EEG spectrum or steady-state visual evoked potentials. IEEE Transactions on Neural Systems and Rehabilitation Engineering 2006, 14:225-229.
    • (2006) IEEE Transactions on Neural Systems and Rehabilitation Engineering , vol.14 , pp. 225-229
    • Trejo, L.J.1    Rosipal, R.2    Matthews, B.3
  • 19
    • 40549086264 scopus 로고    scopus 로고
    • Frequency detection with stability coefficient for SSVEP-based BCIs
    • Wu Z.H., Yao D.Z. Frequency detection with stability coefficient for SSVEP-based BCIs. Journal of Neural Engineering 2008, 5:36-43.
    • (2008) Journal of Neural Engineering , vol.5 , pp. 36-43
    • Wu, Z.H.1    Yao, D.Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.