메뉴 건너뛰기




Volumn 34, Issue 5, 2010, Pages 755-759

Preparation, antibacterial properties and biocompatibility studies on vancomycin-poly(D,L)-lactic loaded plates

Author keywords

[No Author keywords available]

Indexed keywords

POLY DEXTRO LEVO LACTIC ACID; POLYMER; UNCLASSIFIED DRUG; VANCOMYCIN; ALLOY; ANTIINFECTIVE AGENT; BIOMATERIAL; TITANIUM;

EID: 77955958400     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-009-0808-z     Document Type: Article
Times cited : (13)

References (19)
  • 1
    • 33646135083 scopus 로고    scopus 로고
    • Staphylococci and implant surfaces: A review
    • Harris LG, Richards RG (2006) Staphylococci and implant surfaces: A review. Injury 37(suppl 2):S3-S14
    • (2006) Injury , vol.37 , Issue.SUPPL. 2
    • Harris, L.G.1    Richards, R.G.2
  • 2
    • 0024307640 scopus 로고
    • Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation
    • Maurer DJ, Merkow RL, Gustilo RB (1989) Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation. J Bone Joint Surg Am 71(6):835-838
    • (1989) J Bone Joint Surg Am , vol.71 , Issue.6 , pp. 835-838
    • Maurer, D.J.1    Merkow, R.L.2    Gustilo, R.B.3
  • 3
    • 0034952967 scopus 로고    scopus 로고
    • Biodegradable poly (D, L-lactide) coating of implants for continuous release of growth factors
    • Schmidmaier G, Wildemann B, Stemberger A et al (2001) Biodegradable poly (D, L-lactide) coating of implants for continuous release of growth factors. J Biomed Mater Res, Applied Biomat 58(4):449-455
    • (2001) J Biomed Mater Res, Applied Biomat , vol.58 , Issue.4 , pp. 449-455
    • Schmidmaier, G.1    Wildemann, B.2    Stemberger, A.3
  • 4
    • 0035034516 scopus 로고    scopus 로고
    • Local application of growth factors (insulin-like growth factor-1 and transforming growth factor-ß1) from a biodegradable poly(D, Llactide) coating of osteosynthetic implants accelerates fracture healing in rats
    • Schmidmaier G, Wildemann B, Bail H et al (2001) Local application of growth factors (insulin-like growth factor-1 and transforming growth factor-ß1) from a biodegradable poly(D, Llactide) coating of osteosynthetic implants accelerates fracture healing in rats. Bone 28(4):341-350
    • (2001) Bone , vol.28 , Issue.4 , pp. 341-350
    • Schmidmaier, G.1    Wildemann, B.2    Bail, H.3
  • 5
    • 0030239184 scopus 로고    scopus 로고
    • A review of material properties of biodegradable and bioresorbable polymers and devices for GTR and GBR applications
    • Hutmacher D, Hurzeler MB, Schliephake H (1996) A review of material properties of biodegradable and bioresorbable polymers and devices for GTR and GBR applications. Int J Oral Maxillofac Implants 11(5):667-678
    • (1996) Int J Oral Maxillofac Implants , vol.11 , Issue.5 , pp. 667-678
    • Hutmacher, D.1    Hurzeler, M.B.2    Schliephake, H.3
  • 7
    • 0013965320 scopus 로고
    • Polylactic acid for surgical implants
    • Kulkarni RK, Pani KC, Neuman C et al (1966) Polylactic acid for surgical implants. Arch Surg 93(5):839-843
    • (1966) Arch Surg , vol.93 , Issue.5 , pp. 839-843
    • Kulkarni, R.K.1    Pani, K.C.2    Neuman, C.3
  • 8
    • 0024351793 scopus 로고
    • In vitro and in vivo comparative colonization of Staphylococcus aureus and Staphylococcus epidermidis on orthopaedic implant materials
    • Barth E, Myrvik QM, Wagner W et al (1989) In vitro and in vivo comparative colonization of Staphylococcus aureus and Staphylococcus epidermidis on orthopaedic implant materials. Biomaterials 10(5):325-328
    • (1989) Biomaterials , vol.10 , Issue.5 , pp. 325-328
    • Barth, E.1    Myrvik, Q.M.2    Wagner, W.3
  • 9
    • 0034786833 scopus 로고    scopus 로고
    • Coagulase-negative staphylococci. Pathogens have major role in nosocomial infections
    • Von Eiff C, Proctor RA, Peters G (2001) Coagulase-negative staphylococci. Pathogens have major role in nosocomial infections. Postgrad Med 110(4):63-76
    • (2001) Postgrad Med , vol.110 , Issue.4 , pp. 63-76
    • Von Eiff, C.1    Proctor, R.A.2    Peters, G.3
  • 10
    • 0022342163 scopus 로고
    • The influence of skeletal implants on incidence of infection. Experiments in a canine model
    • Petty W, Spanier S, Shuster JJ et al (1985) The influence of skeletal implants on incidence of infection. Experiments in a canine model. J Bone Joint Surg Am 67(8):1236-1244
    • (1985) J Bone Joint Surg Am , vol.67 , Issue.8 , pp. 1236-1244
    • Petty, W.1    Spanier, S.2    Shuster, J.J.3
  • 11
    • 0037338940 scopus 로고    scopus 로고
    • Antibacterial poly (D, L-lactic acid) coating of medical implants using a biodegradable drug delivery technology
    • Gollwitzer H, Ibrahim K, Meyer H et al (2003) Antibacterial poly (D, L-lactic acid) coating of medical implants using a biodegradable drug delivery technology. JAC 51(3):585-591
    • (2003) JAC , vol.51 , Issue.3 , pp. 585-591
    • Gollwitzer, H.1    Ibrahim, K.2    Meyer, H.3
  • 13
    • 77956191844 scopus 로고    scopus 로고
    • ISO ISO 10993-4:2002/Amd 1:2006. Biological evaluation of medical devices - part 4: Selection of tests for interactions with blood. International Organization for Standardization, Geneva, Switzerland
    • ISO (2006) ISO 10993-4:2002/Amd 1:2006. Biological evaluation of medical devices - part 4: Selection of tests for interactions with blood. International Organization for Standardization, Geneva, Switzerland
    • (2006)
  • 14
    • 77956184687 scopus 로고    scopus 로고
    • ISO ISO 10993-5:1999. Biological evaluation of medical devices - part 5: Tests for in vitro cytotoxicity. International Organization for Standardization, Geneva, Switzerland
    • ISO (1999) ISO 10993-5:1999. Biological evaluation of medical devices - part 5: Tests for in vitro cytotoxicity. International Organization for Standardization, Geneva, Switzerland
    • (1999)
  • 15
    • 77956190032 scopus 로고    scopus 로고
    • ISO ISO 10993-10:2002/Amd 1:2006. Biological evaluation of medical devices - part 10: Tests for irritation and delayed-type hypersensitivity. International Organization for Standardization, Geneva, Switzerland
    • ISO (2006) ISO 10993-10:2002/Amd 1:2006. Biological evaluation of medical devices - part 10: Tests for irritation and delayed-type hypersensitivity. International Organization for Standardization, Geneva, Switzerland
    • (2006)
  • 16
    • 77956187707 scopus 로고    scopus 로고
    • ISO ISO 10993-11:2006. Biological evaluation of medical devices - part 11: Tests for systemic toxicity. International Organization for Standardization, Geneva, Switzerland
    • ISO (2006) ISO 10993-11:2006. Biological evaluation of medical devices - part 11: Tests for systemic toxicity. International Organization for Standardization, Geneva, Switzerland
    • (2006)
  • 17
    • 33646150451 scopus 로고    scopus 로고
    • Prophylaxis and treatment of implant-related infections by antibiotic-coated implants: A review
    • Schmidmaier G, Lucke M, Wildemann B et al (2006) Prophylaxis and treatment of implant-related infections by antibiotic-coated implants: A review. Injury 37(suppl 2):S105-S112
    • (2006) Injury , vol.37 , Issue.SUPPL. 2
    • Schmidmaier, G.1    Lucke, M.2    Wildemann, B.3
  • 18
    • 33646137139 scopus 로고    scopus 로고
    • Antibacterial coating systems
    • Montali A (2006) Antibacterial coating systems. Injury 37(Suppl 2):S81-S86
    • (2006) Injury , vol.37 , Issue.SUPPL. 2
    • Montali, A.1
  • 19
    • 57649201378 scopus 로고    scopus 로고
    • Weak effect of metal type and ica genes on staphylococcal infection of titanium and stainless steel implants
    • Hudetz D, UrsicHudetz S, Harris LG et al (2008) Weak effect of metal type and ica genes on staphylococcal infection of titanium and stainless steel implants. Clin Microbiol Infect 14 (12):1135-1145
    • (2008) Clin Microbiol Infect , vol.14 , Issue.12 , pp. 1135-1145
    • Hudetz, D.1    UrsicHudetz, S.2    Harris, L.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.