메뉴 건너뛰기




Volumn 139, Issue 3, 2010, Pages

Acute coronary syndrome due to complete bare metal stent fracture in the right coronary artery

Author keywords

Acute coronary syndrome; Bare metal stent; Stent fracture

Indexed keywords

CREATINE KINASE; TROPONIN I; METAL;

EID: 77955901010     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2008.11.010     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 33845999915 scopus 로고    scopus 로고
    • Two-year clinical outcome after coronary stenting of small vessels using 2.25 mm sirolimus- and paclitaxel-eluting stents: Insight into the RESEARCH and T-SEARCH registries
    • Tanimoto S, Daemen J, Tsuchida K, et al. Two-year clinical outcome after coronary stenting of small vessels using 2.25 mm sirolimus- and paclitaxel-eluting stents: insight into the RESEARCH and T-SEARCH registries. Catheter Cardiovasc Interv 2006;69:94-103.
    • (2006) Catheter Cardiovasc Interv , vol.69 , pp. 94-103
    • Tanimoto, S.1    Daemen, J.2    Tsuchida, K.3
  • 2
    • 33846657988 scopus 로고    scopus 로고
    • Fractured des with a patent coronary artery: Clinical implications
    • Park JS, Shin DG, Kim YJ. Fractured DES with a patent coronary artery: clinical implications. J Invasive Cardiol 2007;19:E 43-E45.
    • (2007) J Invasive Cardiol , vol.19
    • Park, J.S.1    Shin, D.G.2    Kim, Y.J.3
  • 3
    • 11844296114 scopus 로고    scopus 로고
    • Prevalence and clinical impact of stent fractures after femoropopliteal stenting
    • Scheinert D, Scheinert S, Sax J, et al. Prevalence and clinical impact of stent fractures after femoropopliteal stenting. J Am Coll Cardiol 2005;45:312-5.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 312-315
    • Scheinert, D.1    Scheinert, S.2    Sax, J.3
  • 6
    • 34547669112 scopus 로고    scopus 로고
    • Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation
    • Lee SH, Park JS, Kim YJ, Hong GR, Kim W, Shim BS. Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 2007;10(4):627-30.
    • (2007) Am J Cardiol , vol.10 , Issue.4 , pp. 627-630
    • Lee, S.H.1    Park, J.S.2    Kim, Y.J.3    Hong, G.R.4    Kim, W.5    Shim, B.S.6
  • 7
    • 33847339687 scopus 로고    scopus 로고
    • Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    • Aoki J, Nakazawa G, Tanabe K, et al. Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 2007;69:380-6.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 380-386
    • Aoki, J.1    Nakazawa, G.2    Tanabe, K.3
  • 8
    • 33745542078 scopus 로고    scopus 로고
    • Stent strut fractured-induced restenosis in a bifurcation lesion treated with the crush stenting technique
    • Surmely JF, Kinoshita Y, Dash D, Matsubara T, Terashima M, Ehara M, et al. Stent strut fractured-induced restenosis in a bifurcation lesion treated with the crush stenting technique. Circ J 2006;70:936-8.
    • (2006) Circ J , vol.70 , pp. 936-938
    • Surmely, J.F.1    Kinoshita, Y.2    Dash, D.3    Matsubara, T.4    Terashima, M.5    Ehara, M.6
  • 9
    • 34249328412 scopus 로고    scopus 로고
    • Coronary stent fracture in a saphenous vein graft to right coronary artery-successful treatment by the novel use of the Jomed coronary stent graft
    • Koh TW, Mathur A. Coronary stent fracture in a saphenous vein graft to right coronary artery-successful treatment by the novel use of the Jomed coronary stent graft. Int J Cardiol 2007;119:e43-5.
    • (2007) Int J Cardiol , vol.119
    • Koh, T.W.1    Mathur, A.2
  • 10
    • 33745080339 scopus 로고    scopus 로고
    • Stent fracture and collapse in saphenous vein graft causing occlusive restenosis
    • Dorsch MF, Serdelin PH, Blackman DJ. Stent fracture and collapse in saphenous vein graft causing occlusive restenosis. J Invasive Cardiol 2006;18:137-9.
    • (2006) J Invasive Cardiol , vol.18 , pp. 137-139
    • Dorsch, M.F.1    Serdelin, P.H.2    Blackman, D.J.3
  • 11
    • 37349123502 scopus 로고    scopus 로고
    • Acute coronary syndrome due to hinge movement of a bare-metal stent
    • Kimura T, Hayashi I, Nishiuchi T. Acute coronary syndrome due to hinge movement of a bare-metal stent. Int J Cardiol 2008;123(3):e64-6.
    • (2008) Int J Cardiol , vol.123 , Issue.3
    • Kimura, T.1    Hayashi, I.2    Nishiuchi, T.3
  • 12
    • 57549110416 scopus 로고    scopus 로고
    • Ethical authorship and publishing
    • Coats AJ. Ethical authorship and publishing. Int J Cardiol 2009;131:149-50.
    • (2009) Int J Cardiol , vol.131 , pp. 149-150
    • Coats, A.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.