메뉴 건너뛰기




Volumn 88, Issue 3, 2010, Pages 295-298

Limitations of point-of-care testing in the ED or ICU: A role for regional centralized toxicology laboratories

Author keywords

[No Author keywords available]

Indexed keywords

3,4 METHYLENEDIOXYMETHAMPHETAMINE; ALCOHOL; CENTRAL STIMULANT AGENT; COCAINE; DIAMORPHINE; PHENCYCLIDINE; TETRAHYDROCANNABINOL;

EID: 77955900384     PISSN: 00099236     EISSN: 15326535     Source Type: Journal    
DOI: 10.1038/clpt.2010.45     Document Type: Note
Times cited : (13)

References (12)
  • 1
    • 37549009899 scopus 로고    scopus 로고
    • Urine drug screening: Practical guide for clinicians
    • Moeller, K.E., Lee, K.C. & Kissack, J.C. Urine drug screening: practical guide for clinicians. Mayo Clin. Proc. 83, 66-76 (2008).
    • (2008) Mayo Clin. Proc. , vol.83 , pp. 66-76
    • Moeller, K.E.1    Lee, K.C.2    Kissack, J.C.3
  • 2
    • 0012607259 scopus 로고    scopus 로고
    • US Department of Health and Human Services Drug Abuse Warning Network 2006: National Estimates of Drug-Related Emergency Department Visits August 2008
    • US Department of Health and Human Services, Substance Abuse and Mental Health Services Administration. Drug Abuse Warning Network, 2006: National Estimates of Drug-Related Emergency Department Visits (August 2008).
    • Substance Abuse and Mental Health Services Administration
  • 3
    • 44849139904 scopus 로고    scopus 로고
    • Implementation of point-of-care rapid urine testing for drugs of abuse in the emergency department of an academic medical center: Impact on test utilization and ED length of stay
    • Lewandrowski, K. et al. Implementation of point-of-care rapid urine testing for drugs of abuse In the emergency department of an academic medical center: impact on test utilization and ED length of stay. Am. J. Clin. Pathol. 129, 796-801 (2008).
    • (2008) Am. J. Clin. Pathol. , vol.129 , pp. 796-801
    • Lewandrowski, K.1
  • 4
    • 0031032007 scopus 로고    scopus 로고
    • Assessment of an automated immunoassay based on kinetic interaction of microparticles in solution for determination of opiates and cocaine metabolite in urine
    • Smith, F.P., Lora-Tamayo, C., Carvajal, R., Caddy, B. & Tagliaro, F. Assessment of an automated immunoassay based on kinetic interaction of microparticles in solution for determination of opiates and cocaine metabolite in urine. Ann. Clin. Biochem. 34, 81-84 (1997).
    • (1997) Ann. Clin. Biochem. , vol.34 , pp. 81-84
    • Smith, F.P.1    Lora-Tamayo, C.2    Carvajal, R.3    Caddy, B.4    Tagliaro, F.5
  • 6
    • 33646186945 scopus 로고    scopus 로고
    • A comparative evaluation of the instant-view 5-panel test card with OnTrak TesTcup Pro 5: Comparison with gas chromatography-mass spectrometry
    • Moody, D.E., Fang, W.B., Andrenyak, D.M., Monti, K.M. & Jones, C. A comparative evaluation of the instant-view 5-panel test card with OnTrak TesTcup Pro 5: comparison with gas chromatography-mass spectrometry. J. Anal. Toxicol. 30, 50-56 (2006).
    • (2006) J. Anal. Toxicol. , vol.30 , pp. 50-56
    • Moody, D.E.1    Fang, W.B.2    Andrenyak, D.M.3    Monti, K.M.4    Jones, C.5
  • 7
    • 0032498944 scopus 로고    scopus 로고
    • Comparison between the CEDIA and EMIT II immunoassays for the determination of benzodiazepines
    • Way, B.A., Walton, K.G., Koenig, J.W., Eveland, B.J. & Scott, M.G. Comparison between the CEDIA and EMIT II immunoassays for the determination of benzodiazepines. Clin. Chim. Acta 271, 1-9 (1998).
    • (1998) Clin. Chim. Acta , vol.271 , pp. 1-9
    • Way, B.A.1    Walton, K.G.2    Koenig, J.W.3    Eveland, B.J.4    Scott, M.G.5
  • 8
    • 0029004334 scopus 로고
    • False-positive benzodiazepine urine test due to oxaprozin
    • Pulini M. False-positive benzodiazepine urine test due to oxaprozin. JAMA 273, 1905-1906 (1995).
    • (1995) JAMA , vol.273 , pp. 1905-1906
    • Pulini, M.1
  • 9
    • 18244412381 scopus 로고
    • Positive diphenhydramine interference in the EMIT-st Assay for tricyclic antidepressants in serum
    • Sorisky, A & Watson, D.C. Positive diphenhydramine interference in the EMIT-st Assay for tricyclic antidepressants in serum. Clin. Chem. 32, 715 (1986).
    • (1986) Clin. Chem. , vol.32 , pp. 715
    • Sorisky, A.1    Watson, D.C.2
  • 10
    • 0036201327 scopus 로고    scopus 로고
    • False-positive phencyclidine immunoassay results caused by venlafaxine and O-desmethylvenlafaxine
    • Sena, S.F., Kazimi, S. & Wu, A.H. False-positive phencyclidine immunoassay results caused by venlafaxine and O-desmethylvenlafaxine. Clin. Chem. 48, 676-677 (2002).
    • (2002) Clin. Chem. , vol.48 , pp. 676-677
    • Sena, S.F.1    Kazimi, S.2    Wu, A.H.3
  • 11
    • 33646354920 scopus 로고    scopus 로고
    • Characterization of interference with 6 commercial delta9- tetrahydrocannabinol immunoassays by efavirenz (glucuronide) in urine
    • Rossi, S., Yaksh, T., Bentley, H., Van den Brande, G., Grant, I. & Ellis, R. Characterization of interference with 6 commercial delta9-tetrahydrocannabinol immunoassays by efavirenz (glucuronide) in urine. Clin. Chem. 52, 896-897 (2006).
    • (2006) Clin. Chem. , vol.52 , pp. 896-897
    • Rossi, S.1    Yaksh, T.2    Bentley, H.3    Van Den Brande, G.4    Grant, I.5    Ellis, R.6
  • 12
    • 0037372778 scopus 로고    scopus 로고
    • National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Recommendations for the use of laboratory tests to support poisoned patients who present to the emergency department
    • Wu, A.H.B. et al. National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: recommendations for the use of laboratory tests to support poisoned patients who present to the emergency department. Clin. Chem. 49, 357-379 (2003).
    • (2003) Clin. Chem. , vol.49 , pp. 357-379
    • Wu, A.H.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.