메뉴 건너뛰기




Volumn , Issue , 2010, Pages

A method to compare new and traditional accelerometry data in physical activity monitoring

Author keywords

Accelerometer signal processing; Conversion algorithm; Physical activity monitoring

Indexed keywords

ACCELERATION SENSORS; ACCELEROMETER DATA; ACCELEROMETER SIGNALS; ACCELEROMETRY; ACTIGRAPH; CONTROLLED CONDITIONS; CONVERSION ALGORITHM; CORRELATION COEFFICIENT; DE FACTO STANDARD; EPIDEMIOLOGICAL STUDIES; OUTPUT DATA; OUTPUT VALUES; PHYSICAL ACTIVITY; PHYSICAL ACTIVITY MONITORING; SIGNAL PROCESSING TECHNIQUE; TECHNICAL SPECIFICATIONS;

EID: 77955859647     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/WOWMOM.2010.5534986     Document Type: Conference Paper
Times cited : (36)

References (26)
  • 1
    • 69749105447 scopus 로고    scopus 로고
    • Improving the assessment of daily energy expenditure by identifying types of physical activity using a single accelerometer
    • Bonomi, A. G., G. Plasqui, et al. "Improving the assessment of daily energy expenditure by identifying types of physical activity using a single accelerometer." J Appl Physiol., 2009
    • (2009) J Appl Physiol.
    • Bonomi, A.G.1    Plasqui, G.2
  • 2
    • 0038779199 scopus 로고    scopus 로고
    • Reliability and Validity of the Computer Science and Applications Accelerometer in a Mechanical Setting
    • Brage, S., N. Brage, et al. "Reliability and Validity of the Computer Science and Applications Accelerometer in a Mechanical Setting." Measurement in Physical Education and Exercise Science 7(2): 101-119, 2003.
    • (2003) Measurement in Physical Education and Exercise Science , vol.7 , Issue.2 , pp. 101-119
    • Brage, S.1    Brage, N.2
  • 4
    • 28044467315 scopus 로고    scopus 로고
    • The technology of accelerometry-based activity monitors: Current and future
    • Chen, K. Y. and D. R. Bassett, Jr. "The technology of accelerometry-based activity monitors: current and future", Med Sci Sports Exerc 37(11 Suppl): S490-500, 2005.
    • (2005) Med Sci Sports Exerc , vol.37 , Issue.11 SUPPL.
    • Chen, K.Y.1    Bassett Jr., D.R.2
  • 5
    • 34547875078 scopus 로고    scopus 로고
    • Accelerometers and pedometers: Methodology and clinical application
    • Corder, K., S. Brage, et al. "Accelerometers and pedometers: methodology and clinical application." Curr Opin Clin Nutr Metab Care 10(5): 597-603, 2007.
    • (2007) Curr Opin Clin Nutr Metab Care , vol.10 , Issue.5 , pp. 597-603
    • Corder, K.1    Brage, S.2
  • 6
    • 53049093049 scopus 로고    scopus 로고
    • Assessment of physical activity in youth
    • Corder, K., U. Ekelund, et al. "Assessment of physical activity in youth." J Appl Physiol 105(3): 977-87, 2008.
    • (2008) J Appl Physiol , vol.105 , Issue.3 , pp. 977-987
    • Corder, K.1    Ekelund, U.2
  • 7
    • 68849092816 scopus 로고    scopus 로고
    • Population adiposity and climate change
    • Aug
    • Edwards P and Roberts I., "Population adiposity and climate change", Int J Epidemiol., 38(4) pp. 1137-40, Aug 2009.
    • (2009) Int J Epidemiol. , vol.38 , Issue.4 , pp. 1137-1140
    • Edwards, P.1    Roberts, I.2
  • 8
    • 33845362645 scopus 로고    scopus 로고
    • Technical reliability assessment of three accelerometer models in a mechanical setup
    • Esliger, D. W. and M. S. Tremblay. "Technical reliability assessment of three accelerometer models in a mechanical setup." Med Sci Sports Exerc 38(12): 2173-81, 2006.
    • (2006) Med Sci Sports Exerc , vol.38 , Issue.12 , pp. 2173-2181
    • Esliger, D.W.1    Tremblay, M.S.2
  • 9
    • 36249022864 scopus 로고    scopus 로고
    • Foresight, Project Report. Government Office for Science
    • Foresight, "Tackling Obesities: Future Choices", Project Report. Government Office for Science, 2007.
    • (2007) Tackling Obesities: Future Choices
  • 10
    • 0021864277 scopus 로고
    • A validation of two motion sensors in the prediction of child and adult physical activity levels
    • Klesges, R. C., L. M. Klesges, et al. "A validation of two motion sensors in the prediction of child and adult physical activity levels." Am J Epidemiol 122(3): 400-10, 1985.
    • (1985) Am J Epidemiol , vol.122 , Issue.3 , pp. 400-410
    • Klesges, R.C.1    Klesges, L.M.2
  • 11
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin, L. I. "A concordance correlation coefficient to evaluate reproducibility." Biometrics 45(1): 255-68, 1989.
    • (1989) Biometrics , vol.45 , Issue.1 , pp. 255-268
    • Lin, L.I.1
  • 12
    • 0345707499 scopus 로고    scopus 로고
    • The Finnish Diabetes Prevention Study (DPS)
    • Dec
    • Lindstrm J et al, "The Finnish Diabetes Prevention Study (DPS)", Diabetes Care, 26(12) pp. 3230-6, Dec 2003.
    • (2003) Diabetes Care , vol.26 , Issue.12 , pp. 3230-3236
    • Lindstrm, J.1
  • 13
    • 0029010345 scopus 로고
    • Field trial of a three-dimensional activity monitor: Comparison with self report
    • Matthews, C. E. and P. S. Freedson. "Field trial of a three-dimensional activity monitor: comparison with self report." Med Sci Sports Exerc 27(7): 1071-8, 1995.
    • (1995) Med Sci Sports Exerc , vol.27 , Issue.7 , pp. 1071-1078
    • Matthews, C.E.1    Freedson, P.S.2
  • 15
    • 55449111119 scopus 로고    scopus 로고
    • Comparing the performance of three generations of ActiGraph accelerometers
    • Rothney, M. P., G. A. Apker, et al. "Comparing the performance of three generations of ActiGraph accelerometers." J Appl Physiol 105(4): 1091-7, 2008.
    • (2008) J Appl Physiol , vol.105 , Issue.4 , pp. 1091-1097
    • Rothney, M.P.1    Apker, G.A.2
  • 16
    • 34147160106 scopus 로고    scopus 로고
    • Influence of speed and step frequency during walking and running on motion sensor output
    • Rowlands, A. V., M. R. Stone, et al. "Influence of speed and step frequency during walking and running on motion sensor output." Med Sci Sports Exerc 39(4): 716-27, 2007.
    • (2007) Med Sci Sports Exerc , vol.39 , Issue.4 , pp. 716-727
    • Rowlands, A.V.1    Stone, M.R.2
  • 17
    • 38049032926 scopus 로고    scopus 로고
    • Physical activity in the United States measured by accelerometer
    • Troiano, R. P., D. Berrigan, et al. "Physical activity in the United States measured by accelerometer." Med Sci Sports Exerc 40(1): 181-8, 2008
    • (2008) Med Sci Sports Exerc , vol.40 , Issue.1 , pp. 181-188
    • Troiano, R.P.1    Berrigan, D.2
  • 19
    • 67650077374 scopus 로고    scopus 로고
    • Reproducibility of a triaxial seismic accelerometer (DynaPort)
    • Van Hees, V. T., S. M. Slootmaker, et al. "Reproducibility of a triaxial seismic accelerometer (DynaPort)." Med Sci Sports Exerc 41(4): 810-7, 2009.
    • (2009) Med Sci Sports Exerc , vol.41 , Issue.4 , pp. 810-817
    • Van Hees, V.T.1    Slootmaker, S.M.2
  • 20
    • 67650383820 scopus 로고    scopus 로고
    • Estimating Activity-related Energy Expenditure under Sedentary Conditions Using a Triaxial Seismic Accelerometer
    • van Hees, V. T., R. C. van Lummel, et al. "Estimating Activity-related Energy Expenditure Under Sedentary Conditions Using a Triaxial Seismic Accelerometer." Obesity (Silver Spring), 2009.
    • (2009) Obesity (Silver Spring)
    • Van Hees, V.T.1    Van Lummel, R.C.2
  • 21
    • 0030463516 scopus 로고    scopus 로고
    • Detection of static and dynamic activities using uniaxial accelerometers
    • Veltink, P. H., H. B. Bussmann, et al. "Detection of static and dynamic activities using uniaxial accelerometers." IEEE Trans Rehabil Eng 4(4): 375-85, 1996.
    • (1996) IEEE Trans Rehabil Eng , vol.4 , Issue.4 , pp. 375-385
    • Veltink, P.H.1    Bussmann, H.B.2
  • 22
    • 0032927446 scopus 로고    scopus 로고
    • Physical activity assessment with accelerometers
    • Westerterp, K. R. "Physical activity assessment with accelerometers." Int J Obes Relat Metab Disord 23 Suppl 3: S45-9, 2009
    • (2009) Int J Obes Relat Metab Disord , vol.23 , Issue.SUPPL. 3
    • Westerterp, K.R.1
  • 23
    • 67650085827 scopus 로고    scopus 로고
    • Validity and reproducibility of motion sensors in youth: A systematic update
    • Apr; Review
    • De Vries SI, Van Hirtum HW, et al. "Validity and reproducibility of motion sensors in youth: a systematic update." Med Sci Sports Exerc. 2009 Apr;41(4):818-27. Review.
    • (2009) Med Sci Sports Exerc. , vol.41 , Issue.4 , pp. 818-827
    • De Vries, S.I.1    Van Hirtum, H.W.2
  • 24
    • 35648985523 scopus 로고    scopus 로고
    • Physical activity assessment with accelerometers: An evaluation against doubly labeled water
    • Oct. Review
    • Plasqui G, Westerterp KR. "Physical activity assessment with accelerometers: an evaluation against doubly labeled water." Obesity (Silver Spring). 2007 Oct;15(10):2371-9. Review.
    • (2007) Obesity (Silver Spring) , vol.15 , Issue.10 , pp. 2371-9
    • Plasqui, G.1    Westerterp, K.R.2
  • 25
    • 38949198792 scopus 로고    scopus 로고
    • Physical activity and inactivity profiling: The next generation
    • Review
    • Esliger DW, Tremblay MS. "Physical activity and inactivity profiling: the next generation." Can J Public Health. 2007;98 Suppl 2:S195-207. Review.
    • (2007) Can J Public Health , vol.98 , Issue.SUPPL. 2
    • Esliger, D.W.1    Tremblay, M.S.2
  • 26
    • 65249157400 scopus 로고    scopus 로고
    • Activity identification using body-mounted sensors - A review of classification techniques
    • Review
    • Preece SJ, Goulermas JY, et al. "Activity identification using body-mounted sensors - a review of classification techniques." Physiol Meas. 30(4): R1-33. 2009. Review.
    • (2009) Physiol Meas. , vol.30 , Issue.4
    • Preece, S.J.1    Goulermas, J.Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.