메뉴 건너뛰기




Volumn 81, Issue 9, 2010, Pages 1148-1151

Mechanical ventilators in the hot zone: Effects of a CBRN filter on patient protection and battery life

Author keywords

Battery life; CBRN filter; Hazardous environment; Portable ventilator; Triggering

Indexed keywords

ARTICLE; ASPHYXIA; BREATHING RATE; CHEMICAL, BIOLOGICAL, RADIOLOGICAL, OR NUCLEAR FILTER; ELECTRIC BATTERY; FILTER; HUMAN; INSPIRATORY CAPACITY; PORTABLE EQUIPMENT; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; TIDAL VOLUME; VENTILATOR;

EID: 77955846112     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2010.05.006     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 39749097284 scopus 로고    scopus 로고
    • Mass casualty chemical exposure and implications for respiratory failure
    • Muskat P. Mass casualty chemical exposure and implications for respiratory failure. Respir Care 2008, 53:58-66.
    • (2008) Respir Care , vol.53 , pp. 58-66
    • Muskat, P.1
  • 3
    • 42649086816 scopus 로고    scopus 로고
    • Mechanical ventilation in an airborne epidemic
    • Phua G., Govert J. Mechanical ventilation in an airborne epidemic. Clin Chest Med 2008, 29:323-328.
    • (2008) Clin Chest Med , vol.29 , pp. 323-328
    • Phua, G.1    Govert, J.2
  • 4
    • 0343893748 scopus 로고    scopus 로고
    • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • The Acute Respiratory Distress Syndrome Network
    • The Acute Respiratory Distress Syndrome Network Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000, 342:1301-1308.
    • (2000) N Engl J Med , vol.342 , pp. 1301-1308
  • 5
    • 49749096363 scopus 로고    scopus 로고
    • Battery life of the four-hour lithium battery of the LTV-1000 under varying workloads. Mil Med
    • Rodriquez D, Branson R, Barnes S, Johannigman J. Battery life of the four-hour lithium battery of the LTV-1000 under varying workloads. Mil Med 2008;173:792-795.
    • (2008) , vol.173 , pp. 792-795
    • Rodriquez, D.1    Branson, R.2    Barnes, S.3    Johannigman, J.4
  • 6
    • 0036777463 scopus 로고    scopus 로고
    • Battery Duration of Portable Ventilators: Effects of Control Variable, Positive End-Expiratory Pressure, and Inspired Oxygen Concentration. Respiratory Care
    • Campbell R, Johannigman J, Branson R, Austin P, Matacia, G, Banks, et al. Battery Duration of Portable Ventilators: Effects of Control Variable, Positive End-Expiratory Pressure, and Inspired Oxygen Concentration. Respiratory Care 2002;47:1173-1183.
    • (2002) , vol.47 , pp. 1173-1183
    • Campbell, R.1    Johannigman, J.2    Branson, R.3    Austin, P.4    Matacia, G.5    Banks et, al.6
  • 7
    • 77955844533 scopus 로고    scopus 로고
    • 3M Canister C2A1 NBC 2004. 3M Occupational Health and Environmental Safety Division. St. Paul, MN.
    • 3M Canister C2A1 NBC 2004. 3M Occupational Health and Environmental Safety Division. St. Paul, MN.
  • 8
    • 0036616835 scopus 로고    scopus 로고
    • Imposed work of breathing during ventilator failure. Respir Care
    • Austin P, Campbell R, Johannigman J, Branson, R. Imposed work of breathing during ventilator failure. Respir Care 2002;47:667-674.
    • (2002) , vol.47 , pp. 667-674
    • Austin, P.1    Campbell, R.2    Johannigman, J.3    Branson, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.