-
1
-
-
0036305603
-
The systemic inflammatory response to cardiac surgery: Implications for the anesthesiologist
-
Laffey JG, Boylan JF, Cheng DC The systemic inflammatory response to cardiac surgery: implications for the anesthesiologist. Anesthesiology 2002 ; 97: 215-252.
-
(2002)
Anesthesiology
, vol.97
, pp. 215-252
-
-
Laffey, J.G.1
Boylan, J.F.2
Cheng, D.C.3
-
2
-
-
0027768129
-
Organ dysfunction and cardiopulmonary bypass: The role of complement and complement regulatory proteins
-
Moat NE, Shore DF, Evans TW Organ dysfunction and cardiopulmonary bypass: the role of complement and complement regulatory proteins. Eur J Cardiothorac Surg 1993 ; 7: 563-573.
-
(1993)
Eur J Cardiothorac Surg
, vol.7
, pp. 563-573
-
-
Moat, N.E.1
Shore, D.F.2
Evans, T.W.3
-
3
-
-
60449086685
-
Minimal extracorporeal circulation: An alternative for on-pump and off-pump coronary revascularization
-
Puehler T., Haneya A., Philipp A., et al. Minimal extracorporeal circulation: an alternative for on-pump and off-pump coronary revascularization. Ann Thorac Surg 2009 ; 87: 766-772.
-
(2009)
Ann Thorac Surg
, vol.87
, pp. 766-772
-
-
Puehler, T.1
Haneya, A.2
Philipp, A.3
-
4
-
-
0029072668
-
Systemic blood activation with open and closed venous reservoirs
-
Schönberger JP, Everts PA, Hoffmann JJ Systemic blood activation with open and closed venous reservoirs. Ann Thorac Surg 1995 ; 59: 1549-1555.
-
(1995)
Ann Thorac Surg
, vol.59
, pp. 1549-1555
-
-
Schönberger, J.P.1
Everts, P.A.2
Hoffmann, J.J.3
-
5
-
-
0742306910
-
Comparison of the centrifugal and roller pump in elective coronary artery bypass surgery - A prospective, randomized study with special emphasis upon platelet activation
-
Andersen KS, Nygreen EL, Grong K., Leirvaag B., Holmsen H. Comparison of the centrifugal and roller pump in elective coronary artery bypass surgery - a prospective, randomized study with special emphasis upon platelet activation. Scand Cardiovasc J 2003 ; 37: 356-362.
-
(2003)
Scand Cardiovasc J
, vol.37
, pp. 356-362
-
-
Andersen, K.S.1
Nygreen, E.L.2
Grong, K.3
Leirvaag, B.4
Holmsen, H.5
-
6
-
-
0033199710
-
Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation
-
Wendel HP, Ziemer G. Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation. Eur J Cardiothorac Surg 1999 ; 16: 342-350.
-
(1999)
Eur J Cardiothorac Surg
, vol.16
, pp. 342-350
-
-
Wendel, H.P.1
Ziemer, G.2
-
7
-
-
0030271403
-
Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility
-
Moen O., Fosse E., Dregelid E., et al. Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility. Ann Thorac Surg 1996 ; 62: 1134-1140.
-
(1996)
Ann Thorac Surg
, vol.62
, pp. 1134-1140
-
-
Moen, O.1
Fosse, E.2
Dregelid, E.3
-
8
-
-
0032775491
-
Low-dose protamine based on heparin-protamine titration method reduces platelet dysfunction after cardiopulmonary bypass
-
Shigeta O., Kojima H., Hiramatsu Y., et al. Low-dose protamine based on heparin-protamine titration method reduces platelet dysfunction after cardiopulmonary bypass. J Thorac Cardiovasc Surg 1999 ; 118: 354-360.
-
(1999)
J Thorac Cardiovasc Surg
, vol.118
, pp. 354-360
-
-
Shigeta, O.1
Kojima, H.2
Hiramatsu, Y.3
-
9
-
-
0032960211
-
Haemolysis during cardiopulmonary bypass: An in vivo comparison of standard roller pumps, non-occlusive roller pumps and centrifugal pumps
-
Hansbro SD, Sharpe DA, Catchpole R., et al. Haemolysis during cardiopulmonary bypass: an in vivo comparison of standard roller pumps, non-occlusive roller pumps and centrifugal pumps. Perfusion 1999 ; 14: 3-10.
-
(1999)
Perfusion
, vol.14
, pp. 3-10
-
-
Hansbro, S.D.1
Sharpe, D.A.2
Catchpole, R.3
-
10
-
-
0028941017
-
Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasis
-
de Haan J., Boonstra PW, Monnink SH, Ebels T., van Oeveren W. Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasis. Ann Thorac Surg 1995 ; 59: 901-907.
-
(1995)
Ann Thorac Surg
, vol.59
, pp. 901-907
-
-
De Haan, J.1
Boonstra, P.W.2
Monnink, S.H.3
Ebels, T.4
Van Oeveren, W.5
-
11
-
-
0344925046
-
Physiological coagulation can be maintained in extracorporeal circulation by means of shed blood separation and coating
-
Albes JM, Stöhr IM, Kaluza M., et al. Physiological coagulation can be maintained in extracorporeal circulation by means of shed blood separation and coating. J Thorac Cardiovasc Surg 2003 ; 126: 1504-1512.
-
(2003)
J Thorac Cardiovasc Surg
, vol.126
, pp. 1504-1512
-
-
Albes, J.M.1
Stöhr, I.M.2
Kaluza, M.3
-
12
-
-
4544365098
-
The efficacy of low prime volume completely closed cardiopulmonary bypass in coronary artery revascularization
-
Takai H., Eishi K., Yamachika S., et al. The efficacy of low prime volume completely closed cardiopulmonary bypass in coronary artery revascularization. Ann Thorac Cardiovasc Surg 2004 ; 10: 178-182.
-
(2004)
Ann Thorac Cardiovasc Surg
, vol.10
, pp. 178-182
-
-
Takai, H.1
Eishi, K.2
Yamachika, S.3
-
13
-
-
77955830905
-
Combination of autologous transfusion and retrograde autologous priming decreases blood requirements
-
Srinivas K., Singh K. Combination of autologous transfusion and retrograde autologous priming decreases blood requirements. Ann Card Anaesth 2001 ; 4: 28-32.
-
(2001)
Ann Card Anaesth
, vol.4
, pp. 28-32
-
-
Srinivas, K.1
Singh, K.2
-
14
-
-
0037973306
-
Adverse effects of low hematocrit during cardiopulmonary bypass in the adult: Should current practice be changed?
-
Habib RH, Zacharias A., Schwann TA, Riordan CJ, Durham SJ, Shah A. Adverse effects of low hematocrit during cardiopulmonary bypass in the adult: should current practice be changed? J Thorac Cardiovasc Surg 2003 ; 125: 1438-1450
-
(2003)
J Thorac Cardiovasc Surg
, vol.125
, pp. 1438-1450
-
-
Habib, R.H.1
Zacharias, A.2
Schwann, T.A.3
Riordan, C.J.4
Durham, S.J.5
Shah, A.6
-
15
-
-
34247179501
-
Attenuated renal and intestinal injury after use of a mini-cardiopulmonary bypass system
-
Huybregts RA, Morariu AM, Rakhorst G., et al. Attenuated renal and intestinal injury after use of a mini-cardiopulmonary bypass system. Ann Thorac Surg 2007 ; 83: 1760-1766.
-
(2007)
Ann Thorac Surg
, vol.83
, pp. 1760-1766
-
-
Huybregts, R.A.1
Morariu, A.M.2
Rakhorst, G.3
-
16
-
-
73949087368
-
Comparison of two different minimized extracorporeal circulation systems: Hematological effects after coronary surgery
-
Haneya A., Philipp A., Diez C., et al. Comparison of two different minimized extracorporeal circulation systems: hematological effects after coronary surgery. ASAIO J 2009 ; 55: 592-597.
-
(2009)
ASAIO J
, vol.55
, pp. 592-597
-
-
Haneya, A.1
Philipp, A.2
Diez, C.3
-
17
-
-
27544433546
-
Minimal versus conventional cardiopulmonary bypass: Assessment of intraoperative myocardial damage in coronary bypass surgery
-
Immer F., Pirovino C., Gygax E., Englberger L., Tevaearai H., Carrel TP Minimal versus conventional cardiopulmonary bypass: assessment of intraoperative myocardial damage in coronary bypass surgery. Eur J Cardiothorac Surg 2005 ; 28: 701-704.
-
(2005)
Eur J Cardiothorac Surg
, vol.28
, pp. 701-704
-
-
Immer, F.1
Pirovino, C.2
Gygax, E.3
Englberger, L.4
Tevaearai, H.5
Carrel, T.P.6
-
18
-
-
2542485312
-
Clinical experience with the mini-extracorporeal circulation system: An evolution or a revolution?
-
Remadi JP, Marticho P., Butoi I., et al. Clinical experience with the mini-extracorporeal circulation system: an evolution or a revolution? Ann Thorac Surg 2004 ; 77: 2172-2176.
-
(2004)
Ann Thorac Surg
, vol.77
, pp. 2172-2176
-
-
Remadi, J.P.1
Marticho, P.2
Butoi, I.3
|