메뉴 건너뛰기




Volumn 21, Issue 8, 2010, Pages 1280-1286

Tissue contraction caused by radiofrequency and microwave ablation: A laboratory study in liver and lung

Author keywords

radiofrequency; RF

Indexed keywords

ANIMAL TISSUE; ARTICLE; COMPUTER MODEL; DEHYDRATION; INTERMETHOD COMPARISON; LIVER; LUNG; MEASUREMENT; MICROWAVE THERAPY; NONHUMAN; PRIORITY JOURNAL; RADIATION APPLICATOR; RADIOFREQUENCY ABLATION; SMOOTH MUSCLE CONTRACTION; WATER CONTENT; ANIMAL; BODY WATER; CATHETER ABLATION; METABOLISM; MICROWAVE RADIATION; PATHOLOGY; SURGERY; SWINE;

EID: 77955712495     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvir.2010.02.038     Document Type: Article
Times cited : (140)

References (27)
  • 1
    • 40949089014 scopus 로고    scopus 로고
    • Radiofrequency ablation of primary and metastatic liver tumors: A critical review of the literature
    • S. Garrean, J. Hering, A. Saied, W.S. Helton, and N.J. Espat Radiofrequency ablation of primary and metastatic liver tumors: a critical review of the literature Am J Surg 195 2008 508 520
    • (2008) Am J Surg , vol.195 , pp. 508-520
    • Garrean, S.1    Hering, J.2    Saied, A.3    Helton, W.S.4    Espat, N.J.5
  • 2
    • 38649141497 scopus 로고    scopus 로고
    • Sustained complete response and complications rates after radiofrequency ablation of very early hepatocellular carcinoma in cirrhosis: Is resection still the treatment of choice?
    • T. Livraghi, F. Meloni, and M. Di Stasi Sustained complete response and complications rates after radiofrequency ablation of very early hepatocellular carcinoma in cirrhosis: is resection still the treatment of choice? Hepatology 47 2008 82 89
    • (2008) Hepatology , vol.47 , pp. 82-89
    • Livraghi, T.1    Meloni, F.2    Di Stasi, M.3
  • 4
    • 33846297708 scopus 로고    scopus 로고
    • Radiofrequency ablation of osteoid osteoma with cooled probes and impedance-control energy delivery
    • C.P. Cantwell, J. O'Byrne, and S. Eustace Radiofrequency ablation of osteoid osteoma with cooled probes and impedance-control energy delivery AJR Am J Roentgenol 186 Suppl 2006 S244 S248
    • (2006) AJR Am J Roentgenol , vol.186 , Issue.SUPPL.
    • Cantwell, C.P.1    O'Byrne, J.2    Eustace, S.3
  • 5
    • 67649827153 scopus 로고    scopus 로고
    • Image-guided tumor ablation: Standardization of terminology and reporting criteria
    • S.N. Goldberg, C.J. Grassi, and J.F. Cardella Image-guided tumor ablation: standardization of terminology and reporting criteria J Vasc Interv Radiol 20 Suppl 2009 S377 S390
    • (2009) J Vasc Interv Radiol , vol.20 , Issue.SUPPL.
    • Goldberg, S.N.1    Grassi, C.J.2    Cardella, J.F.3
  • 7
    • 0031030127 scopus 로고    scopus 로고
    • Saline-enhanced radio-frequency tissue ablation in the treatment of liver metastases
    • T. Livraghi, S.N. Goldberg, and F. Monti Saline-enhanced radio-frequency tissue ablation in the treatment of liver metastases Radiology 202 1997 205 210
    • (1997) Radiology , vol.202 , pp. 205-210
    • Livraghi, T.1    Goldberg, S.N.2    Monti, F.3
  • 8
    • 0030210698 scopus 로고    scopus 로고
    • Radiofrequency tissue ablation: Increased lesion diameter with a perfusion electrode
    • S.N. Goldberg, G.S. Gazelle, L. Solbiati, W.J. Rittman, and P.R. Mueller Radiofrequency tissue ablation: increased lesion diameter with a perfusion electrode Acad Radiol 3 1996 636 644
    • (1996) Acad Radiol , vol.3 , pp. 636-644
    • Goldberg, S.N.1    Gazelle, G.S.2    Solbiati, L.3    Rittman, W.J.4    Mueller, P.R.5
  • 9
    • 19444375511 scopus 로고    scopus 로고
    • An experimental evaluation of ablation devices for the local treatment of the liver resection edge
    • S. Gananadha, S. Daniel, J. Zhao, and D.L. Morris An experimental evaluation of ablation devices for the local treatment of the liver resection edge Eur J Surg Oncol 31 2005 528 532
    • (2005) Eur J Surg Oncol , vol.31 , pp. 528-532
    • Gananadha, S.1    Daniel, S.2    Zhao, J.3    Morris, D.L.4
  • 11
    • 33344469463 scopus 로고    scopus 로고
    • A floating sleeve antenna yields localized hepatic microwave ablation
    • D. Yang, J.M. Bertram, and M.C. Converse A floating sleeve antenna yields localized hepatic microwave ablation IEEE Trans Biomed Eng 53 2006 533 537
    • (2006) IEEE Trans Biomed Eng , vol.53 , pp. 533-537
    • Yang, D.1    Bertram, J.M.2    Converse, M.C.3
  • 12
    • 33645128447 scopus 로고    scopus 로고
    • Microwave ablation: Results with a 2.45-gHz applicator in ex vivo bovine and in vivo porcine liver
    • A.U. Hines-Peralta, N. Pirani, and P. Clegg Microwave ablation: results with a 2.45-gHz applicator in ex vivo bovine and in vivo porcine liver Radiology 239 2006 94 102
    • (2006) Radiology , vol.239 , pp. 94-102
    • Hines-Peralta, A.U.1    Pirani, N.2    Clegg, P.3
  • 13
    • 0141841679 scopus 로고    scopus 로고
    • Radio-frequency tissue ablation of the liver: In vivo and ex vivo experiments with four different systems
    • A.L. Denys, T. De Baere, and V. Kuoch Radio-frequency tissue ablation of the liver: in vivo and ex vivo experiments with four different systems Eur Radiol 13 2003 2346 2352
    • (2003) Eur Radiol , vol.13 , pp. 2346-2352
    • Denys, A.L.1    De Baere, T.2    Kuoch, V.3
  • 14
    • 0032778383 scopus 로고    scopus 로고
    • Percutaneous radiofrequency tissue ablation: Optimization of pulsed-radiofrequency technique to increase coagulation necrosis
    • S.N. Goldberg, M.C. Stein, G.S. Gazelle, R.G. Sheiman, J.B. Kruskal, and M.E. Clouse Percutaneous radiofrequency tissue ablation: optimization of pulsed-radiofrequency technique to increase coagulation necrosis J Vasc Interv Radiol 10 1999 907 916
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 907-916
    • Goldberg, S.N.1    Stein, M.C.2    Gazelle, G.S.3    Sheiman, R.G.4    Kruskal, J.B.5    Clouse, M.E.6
  • 15
    • 0000097040 scopus 로고    scopus 로고
    • Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases
    • S.N. Goldberg, L. Solbiati, and P.F. Hahn Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: laboratory and clinical experience in liver metastases Radiology 209 1998 371 379
    • (1998) Radiology , vol.209 , pp. 371-379
    • Goldberg, S.N.1    Solbiati, L.2    Hahn, P.F.3
  • 16
    • 0031964917 scopus 로고    scopus 로고
    • Percutaneous radiofrequency tissue ablation: Does perfusion-mediated tissue cooling limit coagulation necrosis?
    • S.N. Goldberg, P.F. Hahn, and K.K. Tanabe Percutaneous radiofrequency tissue ablation: does perfusion-mediated tissue cooling limit coagulation necrosis? J Vasc Interv Radiol 9 1998 101 111
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 101-111
    • Goldberg, S.N.1    Hahn, P.F.2    Tanabe, K.K.3
  • 17
    • 34548863132 scopus 로고    scopus 로고
    • Radiofrequency ablation of renal tumors improved by preoperative ex-vivo computer simulation model
    • DOI 10.1089/end.2006.0458
    • M. Meyer, H. Velte, H. Lindenborn, A. Bangert, D. Dahlhaus, and P. Albers Radiofrequency ablation of renal tumors improved by preoperative ex-vivo computer simulation model J Endourol 21 2007 886 890 (Pubitemid 47443679)
    • (2007) Journal of Endourology , vol.21 , Issue.8 , pp. 886-890
    • Meyer, M.1    Velte, H.2    Lindenborn, H.3    Bangert, A.4    Dahlhaus, D.5    Albers, P.6
  • 18
    • 84903803795 scopus 로고    scopus 로고
    • Therapy planning and monitoring of tissue ablation by high intensity focused ultrasound (HIFU) using imaging and simulation
    • V. Amin, L. Wu, T. Long, R. Roberts, S. McClure, and T. Ryken Therapy planning and monitoring of tissue ablation by high intensity focused ultrasound (HIFU) using imaging and simulation Conf Proc IEEE Eng Med Biol Soc 2008 2008 4471
    • (2008) Conf Proc IEEE Eng Med Biol Soc , vol.2008 , pp. 4471
    • Amin, V.1    Wu, L.2    Long, T.3    Roberts, R.4    McClure, S.5    Ryken, T.6
  • 21
    • 33846354167 scopus 로고    scopus 로고
    • Measurement and analysis of tissue temperature during microwave liver ablation
    • D. Yang, M.C. Converse, D.M. Mahvi, and J.G. Webster Measurement and analysis of tissue temperature during microwave liver ablation IEEE Trans Biomed Eng 54 2007 150 155
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 150-155
    • Yang, D.1    Converse, M.C.2    Mahvi, D.M.3    Webster, J.G.4
  • 22
    • 33846457355 scopus 로고    scopus 로고
    • Microwave ablation with a single small-gauge triaxial antenna: In vivo porcine liver model
    • C.L. Brace, P.F. Laeseke, L.A. Sampson, T.M. Frey, D.W. van der Weide, and F.T. Lee Jr Microwave ablation with a single small-gauge triaxial antenna: in vivo porcine liver model Radiology 242 2007 435 440
    • (2007) Radiology , vol.242 , pp. 435-440
    • Brace, C.L.1    Laeseke, P.F.2    Sampson, L.A.3    Frey, T.M.4    Van Der Weide, D.W.5
  • 23
    • 34447508063 scopus 로고    scopus 로고
    • Expanding the bioheat equation to include tissue internal water evaporation during heating
    • D. Yang, M.C. Converse, D.M. Mahvi, and J.G. Webster Expanding the bioheat equation to include tissue internal water evaporation during heating IEEE Trans Biomed Eng 54 2007 1382 1388
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 1382-1388
    • Yang, D.1    Converse, M.C.2    Mahvi, D.M.3    Webster, J.G.4
  • 24
    • 0033766550 scopus 로고    scopus 로고
    • Creation of radiofrequency lesions in a porcine model: Correlation with sonography, CT, and histopathology
    • S.S. Raman, D.S. Lu, D.J. Vodopich, J. Sayre, and C. Lassman Creation of radiofrequency lesions in a porcine model: correlation with sonography, CT, and histopathology AJR Am J Roentgenol 175 2000 1253 1258
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 1253-1258
    • Raman, S.S.1    Lu, D.S.2    Vodopich, D.J.3    Sayre, J.4    Lassman, C.5
  • 25
    • 0042386313 scopus 로고    scopus 로고
    • Radiologic appearance and complications of percutaneous computed tomography-guided radiofrequency-ablated pulmonary metastases from colorectal carcinoma
    • K. Steinke, J. King, D. Glenn, and D.L. Morris Radiologic appearance and complications of percutaneous computed tomography-guided radiofrequency-ablated pulmonary metastases from colorectal carcinoma J Comput Assist Tomogr 27 2003 750 757
    • (2003) J Comput Assist Tomogr , vol.27 , pp. 750-757
    • Steinke, K.1    King, J.2    Glenn, D.3    Morris, D.L.4
  • 27
    • 67049161897 scopus 로고    scopus 로고
    • Pulmonary thermal ablation: Comparison of radiofrequency and microwave devices by using gross pathologic and CT findings in a swine model
    • C.L. Brace, J.L. Hinshaw, P.F. Laeseke, L.A. Sampson, and F.T. Lee Jr Pulmonary thermal ablation: comparison of radiofrequency and microwave devices by using gross pathologic and CT findings in a swine model Radiology 251 2009 705 711
    • (2009) Radiology , vol.251 , pp. 705-711
    • Brace, C.L.1    Hinshaw, J.L.2    Laeseke, P.F.3    Sampson, L.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.