메뉴 건너뛰기




Volumn 24, Issue 7, 2010, Pages 420-425

Superior versus anteroinferior plating of the clavicle revisited: A mechanical study

Author keywords

Anteroinferior; Biomechanics; Clavicle; Plating; Superior

Indexed keywords

ARTICLE; BIOMECHANICS; BONE PLATE; CLAVICLE FRACTURE; FRACTURE FIXATION; FRACTURE TREATMENT; INTERMETHOD COMPARISON; LOADING TEST; PLATE FIXATION; PRIORITY JOURNAL; TORQUE; TORSION;

EID: 77955686648     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3181c3f6d4     Document Type: Article
Times cited : (63)

References (20)
  • 1
    • 0025484793 scopus 로고
    • Migration of pins used in operations on the shoulder
    • Lyons FA, Rockwood CA. Migration of pins used in operations on the shoulder. J Bone Joint Surg Am. 1990;72:1262-1267.
    • (1990) J Bone Joint Surg Am. , vol.72 , pp. 1262-1267
    • Lyons, F.A.1    Rockwood, C.A.2
  • 2
    • 0026045253 scopus 로고
    • Non-union of fractures of the midshaft of the clavicle: Treatment with a modified Hagie intramedullary pin and autogenous bone-grafting
    • Boehme D, Curtis RJ, De Haan JT, et al. Non-union of fractures of the midshaft of the clavicle: treatment with a modified Hagie intramedullary pin and autogenous bone-grafting. J Bone Joint Surg Am. 1991;73:1219-1226.
    • (1991) J Bone Joint Surg Am. , vol.73 , pp. 1219-1226
    • Boehme, D.1    Curtis, R.J.2    De Haan, J.T.3
  • 3
    • 0022374488 scopus 로고
    • The operative treatment of mid-shaft clavicular non-unions
    • Manske DJ, Szabo RM. The operative treatment of mid-shaft clavicular non-unions. J Bone Joint Surg Am. 1985;67:1367-1371.
    • (1985) J Bone Joint Surg Am. , vol.67 , pp. 1367-1371
    • Manske, D.J.1    Szabo, R.M.2
  • 4
    • 24644480089 scopus 로고    scopus 로고
    • Treatment of acute midshaft clavicle fractures: Systematic review of 2144 fractures
    • Zlowodzki M, Zelle BA, Cole PA, et al. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures. J Orthop Trauma. 2005;19:504-507.
    • (2005) J Orthop Trauma. , vol.19 , pp. 504-507
    • Zlowodzki, M.1    Zelle, B.A.2    Cole, P.A.3
  • 5
    • 33751055846 scopus 로고    scopus 로고
    • Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle
    • Collinge C, Devinney S, Herscovici D, et al. Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle. J Orthop Trauma. 2006;20:680-686.
    • (2006) J Orthop Trauma. , vol.20 , pp. 680-686
    • Collinge, C.1    Devinney, S.2    Herscovici, D.3
  • 6
    • 0036065856 scopus 로고    scopus 로고
    • Anteroinferior plating of midshaft clavicular nonunions
    • Kloen P, Sorkin AT, Rubel IF, et al. Anteroinferior plating of midshaft clavicular nonunions. J Orthop Trauma. 2002;16:425-430.
    • (2002) J Orthop Trauma. , vol.16 , pp. 425-430
    • Kloen, P.1    Sorkin, A.T.2    Rubel, I.F.3
  • 7
    • 14844287022 scopus 로고    scopus 로고
    • Plate fixation of middlethird fractures of the clavicle in the semi-professional athlete
    • Verborgt O, Pittoors K, Van Glabbeek F, et al. Plate fixation of middlethird fractures of the clavicle in the semi-professional athlete. Acta Orthop Belg. 2005;71:17-21.
    • (2005) Acta Orthop Belg. , vol.71 , pp. 17-21
    • Verborgt, O.1    Pittoors, K.2    Van Glabbeek, F.3
  • 8
    • 0040384447 scopus 로고
    • Biomechanics of the shoulder
    • Philadelphia: Lippincott Williams & Wilkins
    • DePalma AF. Biomechanics of the shoulder. In: Surgery of the Shoulder. Philadelphia: Lippincott Williams & Wilkins; 1983:65-85.
    • (1983) Surgery of the Shoulder , pp. 65-85
    • Depalma, A.F.1
  • 9
    • 0027575821 scopus 로고
    • Geometric properties and the predicted mechanical behavior of adult human clavicles
    • Harrington MA, Keller TS, Seiler JG, et al. Geometric properties and the predicted mechanical behavior of adult human clavicles. J Biomech. 1993; 26:417-426.
    • (1993) J Biomech. , vol.26 , pp. 417-426
    • Harrington, M.A.1    Keller, T.S.2    Seiler, J.G.3
  • 10
    • 84872438925 scopus 로고
    • Observations on the function of the clavicle
    • Inman VT, Saunders M. Observations on the function of the clavicle. Calif Med. 1946;65:158-166.
    • (1946) Calif Med. , vol.65 , pp. 158-166
    • Inman, V.T.1    Saunders, M.2
  • 14
    • 0030200943 scopus 로고    scopus 로고
    • Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect
    • Harnroongroj T, Vanadurongwan V. Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect. Clin Biomech. 1996;11:290-294.
    • (1996) Clin Biomech. , vol.11 , pp. 290-294
    • Harnroongroj, T.1    Vanadurongwan, V.2
  • 15
    • 0041346511 scopus 로고    scopus 로고
    • Effects of plate location and selection on the stability of midshaft clavicle osteotomies: A biomechanical study
    • Iannotti MR, Crosby LA, Stafford P, et al. Effects of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study. J Shoulder Elbow Surg. 2002;11:457-462.
    • (2002) J Shoulder Elbow Surg. , vol.11 , pp. 457-462
    • Iannotti, M.R.1    Crosby, L.A.2    Stafford, P.3
  • 16
    • 42049088290 scopus 로고    scopus 로고
    • Biomechanical evaluation of clavicle fracture plating techniques: Does a locking plate provide improved stability?
    • Celestre P, Robertson P, Mahar A, et al. Biomechanical evaluation of clavicle fracture plating techniques: does a locking plate provide improved stability? J Orthop Trauma. 2008;22:241-247.
    • (2008) J Orthop Trauma. , vol.22 , pp. 241-247
    • Celestre, P.1    Robertson, P.2    Mahar, A.3
  • 17
    • 26444439066 scopus 로고    scopus 로고
    • A new approach for plate fixation of midshaft clavicular fractures
    • Coupe BD,Wimhurst JA, Indar R, et al. A new approach for plate fixation of midshaft clavicular fractures. Injury. 2005;36:1166-1171.
    • (2005) Injury. , vol.36 , pp. 1166-1171
    • Coupe, B.D.1    Wimhurst, J.A.2    Indar, R.3
  • 18
    • 11244272783 scopus 로고    scopus 로고
    • Bilateral clavicle non-unions treated with anteroinferior locking compression plating (LCP): A case report
    • Kloen P. Bilateral clavicle non-unions treated with anteroinferior locking compression plating (LCP): a case report. Acta Orthop Belg. 2004;70: 609-611.
    • (2004) Acta Orthop Belg. , vol.70 , pp. 609-611
    • Kloen, P.1
  • 19
    • 43149116344 scopus 로고    scopus 로고
    • Locking compression plate in long standing clavicular nonunions with poor bone stock
    • Khan SA, Shamshery P, Gupta V, et al. Locking compression plate in long standing clavicular nonunions with poor bone stock. J Trauma. 2008;64: 439-441.
    • (2008) J Trauma. , vol.64 , pp. 439-441
    • Khan, S.A.1    Shamshery, P.2    Gupta, V.3
  • 20
    • 3042745625 scopus 로고    scopus 로고
    • Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture
    • Robinson CM, Court-Brown CM, McQueen MM, et al. Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture. J Bone Joint Surg Am. 2004;86:1359-1365.
    • (2004) J Bone Joint Surg Am. , vol.86 , pp. 1359-1365
    • Robinson, C.M.1    Court-Brown, C.M.2    McQueen, M.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.