메뉴 건너뛰기




Volumn 52, Issue 9, 2010, Pages 2114-2118

PMMA (polymethyl methacrylate) fiber optic probe as a noncontact liquid level sensor

Author keywords

Fiber optic level sensor; Fiber optic probe; PMMA fiber

Indexed keywords

BIOANALYTICS; DEGREE OF SENSITIVITY; DIGITAL MULTIMETERS; DYNAMIC RANGE; FIBER OPTIC PROBE; FIBER OPTIC TRANSMITTERS; FIBEROPTIC PROBES; HIGH PRECISION; LEVEL SENSORS; LIQUID LEVEL; LIQUID LEVEL SENSORS; LONG TERM STABILITY; LOW COSTS; NON-CONTACT; NON-CONTACT SENSING; NUMERICAL APERTURE; ON-LINE MEASUREMENT; PHOTODIODE DETECTOR; PMMA FIBER; PROCESS CHEMISTRY;

EID: 77955686240     PISSN: 08952477     EISSN: 10982760     Source Type: Journal    
DOI: 10.1002/mop.25415     Document Type: Article
Times cited : (26)

References (17)
  • 3
    • 34247862323 scopus 로고    scopus 로고
    • OTDR based fibre optic microbend sensor for distributed sensing applications in structural pressure monitoring
    • S. Binu, V.P. Mahadevan Pillai, and N. Chandrasekaran, OTDR based fibre optic microbend sensor for distributed sensing applications in structural pressure monitoring, J Opt 35 (2006), 36-44.
    • (2006) J Opt , vol.35 , pp. 36-44
    • Binu, S.1    Mahadevan Pillai, V.P.2    Chandrasekaran, N.3
  • 4
    • 46349099244 scopus 로고    scopus 로고
    • Fibre-optic sensing: A historic perspective
    • B. Culshaw and A. Kersey, Fibre-optic sensing: A historic perspective, J Lightwave Technol 26 (2008), 1064-1078.
    • (2008) J Lightwave Technol , vol.26 , pp. 1064-1078
    • Culshaw, B.1    Kersey, A.2
  • 5
    • 40249100335 scopus 로고    scopus 로고
    • Oil and gas applications: Probing oil fields
    • H. Nakstad and J.T. Kringlebotn, Oil and gas applications: Probing oil fields, Nat Photon 2 (2008), 147-149.
    • (2008) Nat Photon , vol.2 , pp. 147-149
    • Nakstad, H.1    Kringlebotn, J.T.2
  • 6
    • 0038372367 scopus 로고    scopus 로고
    • Review of the present status of optical fibre sensors
    • B. Lee, Review of the present status of optical fibre sensors, Opt Fibre Technol 9 (2003), 57-79.
    • (2003) Opt Fibre Technol , vol.9 , pp. 57-79
    • Lee, B.1
  • 7
    • 0026933081 scopus 로고
    • Sub-micrometer intracellular chemical optical fiber sensors
    • W. Tan, Z.Y. Shi, S. Smith, D. Birnbaum, and R. Kopelman, Sub-micrometer intracellular chemical optical fiber sensors, Science 258 (1992), 778-781.
    • (1992) Science , vol.258 , pp. 778-781
    • Tan, W.1    Shi, Z.Y.2    Smith, S.3    Birnbaum, D.4    Kopelman, R.5
  • 8
    • 0026254805 scopus 로고
    • Displacement response, detection limit, and dynamic range of fibre-optic lever sensors
    • G. He and F.W. Cuomo, Displacement response, detection limit, and dynamic range of fibre-optic lever sensors, IEEE J Lightwave Technol 9 (1991), 1618-1625.
    • (1991) IEEE J Lightwave Technol , vol.9 , pp. 1618-1625
    • He, G.1    Cuomo, F.W.2
  • 9
    • 4444383335 scopus 로고    scopus 로고
    • Multi-sensor system using plastic optical fibers for intrinsically safe level measurements
    • C. Vázquez, A.B. Gonzalo, S. Vargas, and J. Montalvo, Multi-sensor system using plastic optical fibers for intrinsically safe level measurements, Sens Actuators A 116 (2004), 22-32.
    • (2004) Sens Actuators A , vol.116 , pp. 22-32
    • Vázquez, C.1    Gonzalo, A.B.2    Vargas, S.3    Montalvo, J.4
  • 10
    • 33646255110 scopus 로고    scopus 로고
    • An optical-fibre re-fractometric liquid-level sensor for liquid nitrogen
    • K.E. Romo-Medrano and S.N. Khotiaintsev, An optical-fibre re-fractometric liquid-level sensor for liquid nitrogen, Meas Sci Technol 17 (2006), 998-1004.
    • (2006) Meas Sci Technol , vol.17 , pp. 998-1004
    • Romo-Medrano, K.E.1    Khotiaintsev, S.N.2
  • 11
    • 34748856394 scopus 로고    scopus 로고
    • Calibration of accelerometers by using an extrinsic fibre optic probe
    • S. Binu, Calibration of accelerometers by using an extrinsic fibre optic probe, Microwave Opt Technol Lett 49 (2007), 2700-2703.
    • (2007) Microwave Opt Technol Lett , vol.49 , pp. 2700-2703
    • Binu, S.1
  • 12
    • 34047275238 scopus 로고    scopus 로고
    • Fibre optic displacement sensor for the measurement of amplitude and frequency of vibration
    • S. Binu, V.P. Mahadevan Pillai, and N. Chandrasekaran, Fibre optic displacement sensor for the measurement of amplitude and frequency of vibration, Opt Laser Technol 39 (2007), 1537-1543.
    • (2007) Opt Laser Technol , vol.39 , pp. 1537-1543
    • Binu, S.1    Mahadevan Pillai, V.P.2    Chandrasekaran, N.3
  • 14
    • 0037208325 scopus 로고    scopus 로고
    • Fibre optic probes for biomedical optical spectroscopy
    • U. Utzinger and R.R. Richards-Kortum, Fibre optic probes for biomedical optical spectroscopy, J Biomed Opt 8 (2003), 121-147.
    • (2003) J Biomed Opt , vol.8 , pp. 121-147
    • Utzinger, U.1    Richards-Kortum, R.R.2
  • 15
    • 0018530576 scopus 로고
    • Fibre optic lever displacement transducer
    • R.O. Cook and C.W. Hamm, Fibre optic lever displacement transducer, Appl Opt 18 (1979), 3230-3241.
    • (1979) Appl Opt , vol.18 , pp. 3230-3241
    • Cook, R.O.1    Hamm, C.W.2
  • 16
    • 0011005302 scopus 로고    scopus 로고
    • Plastic optical fibres: An introduction to their technological processes and applications
    • J. Zubia and J. Arrue, Plastic optical fibres: An introduction to their technological processes and applications, Opt Fibre Technol 7 (2001), 101-140.
    • (2001) Opt Fibre Technol , vol.7 , pp. 101-140
    • Zubia, J.1    Arrue, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.