메뉴 건너뛰기




Volumn 24, Issue 4, 2010, Pages 252-255

Flow cytometric reticulocyte counting: A comparison between two methods

Author keywords

Blood disease; Erythropoiesis; Flow cytometric count; Reference intervals; Reticulocyte

Indexed keywords

AURAMINE; FLUORESCENT DYE; OXAZINE DERIVATIVE;

EID: 77955625483     PISSN: 08878013     EISSN: 10982825     Source Type: Journal    
DOI: 10.1002/jcla.20394     Document Type: Article
Times cited : (5)

References (18)
  • 2
    • 12644285335 scopus 로고
    • Apport du compteur de reticulocytes Sysmex R-100 pour le suivi de patients en aplasie post-therapeutique
    • Lesesve JF, Lacombe F, Bernard PH, Belloc F, Boisseau MR, Reiffers J. Apport du compteur de reticulocytes Sysmex R-100 pour le suivi de patients en aplasie post-therapeutique. Rev Fr Lab 1993;252:65-69.
    • (1993) Rev Fr Lab , vol.252 , pp. 65-69
    • Lesesve, J.F.1    Lacombe, F.2    Bernard, P.H.3    Belloc, F.4    Boisseau, M.R.5    Reiffers, J.6
  • 3
    • 7144228629 scopus 로고    scopus 로고
    • Proposed reference method for reticulocyte counting based on the determination of the reticulocyte to red cell ratio
    • International Council for Standardisation in Hematology Expert Panel on Cytometry
    • International Council for Standardisation in Hematology Expert Panel on Cytometry. Proposed reference method for reticulocyte counting based on the determination of the reticulocyte to red cell ratio. Clin Lab Haematol 1998;20:77-79.
    • (1998) Clin Lab Haematol , vol.20 , pp. 77-79
  • 4
    • 14444277199 scopus 로고
    • Omptage des reticulocytes sur frottis: Limite de confiance et utilization des resultats
    • Goguel A. omptage des reticulocytes sur frottis: Limite de confiance et utilization des resultats. Rev Fr Lab 1991;225:20-22.
    • (1991) Rev Fr Lab , vol.225 , pp. 20-22
    • Goguel, A.1
  • 5
    • 0022338842 scopus 로고
    • Analytic inaccuracy and imprecision in reticulocyte counting: A preliminary report from the college of American Pathologists reticulocyte project
    • Savage RA, Skoog DP, Rabinovitch A. Analytic inaccuracy and imprecision in reticulocyte counting: A preliminary report from the College of American Pathologists reticulocyte project. Blood Cells 1985;1:97-112. (Pubitemid 16178595)
    • (1985) Blood Cells , vol.11 , Issue.1 , pp. 97-112
    • Savage, R.A.1    Skoog, D.P.2    Rabinovitch, A.3
  • 6
    • 0020505199 scopus 로고
    • Flow cytometry of reticulocytes applied to clinical hematology
    • Tanke HJ, Rothbarth PH, Vossen JMJJ, et al. Flow cytometry of reticulocytes applied to clinical hematology. Blood 1983;61:1091-1097.
    • (1983) Blood , vol.61 , pp. 1091-1097
    • Tanke, H.J.1    Rothbarth, P.H.2    Vossen, J.M.J.J.3
  • 7
    • 0013640694 scopus 로고
    • National Committee for Clinical laboratory Standards. Villanova PA: National Committee for Clinical Laboratory Standards, NCCLS document H16-P
    • National Committee for Clinical laboratory Standards. Methods for reticulocyte counting: Proposed standards. Villanova PA: National Committee for Clinical Laboratory Standards, 1985. NCCLS document H16-P.
    • (1985) Methods for Reticulocyte Counting: Proposed Standards
  • 8
    • 0024375498 scopus 로고
    • Flow cytometric reticulocyte quantification using thiazole orange provides clinically useful reticulocyte maturity index
    • Davis BH, Bigelow NC. Flow cytometric reticulocyte quantification using thiazole orange provides clinically useful reticulocyte maturity index. Arch Pathol Lab Med 1989;113:684-689.
    • (1989) Arch Pathol Lab Med , vol.113 , pp. 684-689
    • Davis, B.H.1    Bigelow, N.C.2
  • 9
    • 0025162083 scopus 로고
    • Evaluation of reticulocyte counts by flow cytometry in a routine laboratory
    • Fergusson DJ, Lee SF, Gordon PA. Evaluation of reticulocyte counts by flow cytometry in a routine laboratory. Am J Hematol 1990;33:13-17.
    • (1990) Am J Hematol , vol.33 , pp. 13-17
    • Fergusson, D.J.1    Lee, S.F.2    Gordon, P.A.3
  • 10
    • 0004087604 scopus 로고    scopus 로고
    • National Committee for Clinical laboratory Standards. Villanova PA: National Committee for Clinical Laboratory Standards, NCCLS document H44-A
    • National Committee for Clinical laboratory Standards. Methods for reticulocyte counting (flow cytometry and supravital dyes); approved guidelines. Villanova PA: National Committee for Clinical Laboratory Standards, 1997. NCCLS document H44-A.
    • (1997) Methods for Reticulocyte Counting (Flow Cytometry and Supravital Dyes); Approved Guidelines
  • 11
    • 0029828269 scopus 로고    scopus 로고
    • Reticulocyte quantification by Coulter MAXM VCS (volume, conductivity, light scatter) technology
    • Buttarello M, Bulian P, De Pra' M, et al. Reticulocyte quantification by Coulter MAXM VCS (volume, conductivity, light scatter) technology. Clin Chem 1996;42:1930-1937. (Pubitemid 26415341)
    • (1996) Clinical Chemistry , vol.42 , Issue.12 , pp. 1930-1937
    • Buttarello, M.1    Bulian, P.2    De Pra, M.3    Barbera, P.4    Rizzotti, P.5
  • 12
    • 0029562718 scopus 로고
    • Laboratory evaluation of the Miles H3 automated reticulocyte counter: A comparative study with manual reference method and Sysmex R-1000
    • Buttarello M, Bulian P, Venudo A, et al. Laboratory evaluation of the Miles H3 automated reticulocyte counter: A comparative study with manual reference method and Sysmex R-1000.Arch Pathos Lab Med 1995;119:1141-1148.
    • (1995) Arch Pathos Lab Med , vol.119 , pp. 1141-1148
    • Buttarello, M.1    Bulian, P.2    Venudo, A.3
  • 13
    • 0002849130 scopus 로고    scopus 로고
    • College of American Pathologists' reticulocyte proficiency testing program using surrogate blood: Insights into contemporary clinical practice
    • Davis BH, Spier CM, Kachin J, et al. College of American Pathologists' reticulocyte proficiency testing program using surrogate blood: Insights into contemporary clinical practice. Lab Hematol 1997;3:84-91.
    • (1997) Lab Hematol , vol.3 , pp. 84-91
    • Davis, B.H.1    Spier, C.M.2    Kachin, J.3
  • 15
    • 0002241473 scopus 로고    scopus 로고
    • Immature reticulocyte fraction(IRF): By any name, a useful clinical parameter of erythropoietic activity
    • Davis BH. Immature reticulocyte fraction(IRF): By any name, a useful clinical parameter of erythropoietic activity. Lab Hematol 1996;2:2-8.
    • (1996) Lab Hematol , vol.2 , pp. 2-8
    • Davis, B.H.1
  • 17
    • 0030740848 scopus 로고    scopus 로고
    • Comparison of a semi-automated new Coulter methylene blue method with fluorescence flow cytometry in reticulocyte counting
    • Rudensky B. Comparison of semi-automated new Coulter methylene blue method with fluorescence flow cytometry in reticulocyte counting. Scand J Clin Lab Invest 1997;57:291-296. (Pubitemid 27296692)
    • (1997) Scandinavian Journal of Clinical and Laboratory Investigation , vol.57 , Issue.4 , pp. 291-296
    • Rudensky, B.1
  • 18
    • 0026552366 scopus 로고
    • Kinetics of erythrogenesis after bone marrow transplantation
    • Lazarus HM, Chahine A, Lacerna K, et al. Kinetics of erythrogenesis after bone marrow transplantation. Am J Clin Pathol 1992;97:574-583.
    • (1992) Am J Clin Pathol , vol.97 , pp. 574-583
    • Lazarus, H.M.1    Chahine, A.2    Lacerna, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.