메뉴 건너뛰기




Volumn 468, Issue 9, 2010, Pages 2377-2381

Intraoperative femur fracture is associated with stem and instrument design in primary total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

BONE STRESS; CONFERENCE PAPER; CONTROLLED STUDY; FEMUR FRACTURE; HUMAN; INCIDENCE; MAJOR CLINICAL STUDY; MEDICAL INSTRUMENTATION; PEROPERATIVE COMPLICATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SURGICAL APPROACH; TORQUE; TOTAL HIP PROSTHESIS;

EID: 77955574000     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1007/s11999-010-1314-8     Document Type: Conference Paper
Times cited : (55)

References (21)
  • 1
    • 42449154310 scopus 로고    scopus 로고
    • Case report: Superficial femoral artery injury resulting from cerclage wiring during revision THA
    • 10.1007/s11999-007-0109-z 18196363
    • T Aleto MA Ritter ME Berend 2008 Case report: superficial femoral artery injury resulting from cerclage wiring during revision THA Clin Orthop Relat Res. 466 749 753 10.1007/s11999-007-0109-z 18196363
    • (2008) Clin Orthop Relat Res. , vol.466 , pp. 749-753
    • Aleto, T.1    Ritter, M.A.2    Berend, M.E.3
  • 2
    • 5344276587 scopus 로고    scopus 로고
    • Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: Results at 2 to 16 Years
    • DOI 10.1016/j.arth.2004.06.008, PII S0883540304003298
    • KR Berend AV Lombardi Jr TH Mallory DJ Chonko KL Dodds JB Adams 2004 Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years J Arthroplasty 19 Suppl 2 17 21 10.1016/j.arth.2004.06.008 15457413 (Pubitemid 39349012)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.SUPPL. , pp. 17-21
    • Berend, K.R.1    Lombardi Jr., A.V.2    Mallory, T.H.3    Chonko, D.J.4    Dodds, K.L.5    Adams, J.B.6
  • 3
    • 0036084025 scopus 로고    scopus 로고
    • Management of periprosthetic fractures: The hip
    • DOI 10.1054/arth.2002.32682
    • DJ Berry 2002 Management of periprosthetic fractures: the hip J Arthroplasty. 17 11 13 10.1054/arth.2002.32682 12068395 (Pubitemid 34663215)
    • (2002) Journal of Arthroplasty , vol.17 , Issue.SUPPL. 1 , pp. 11-13
    • Berry, D.J.1
  • 4
    • 0029187931 scopus 로고    scopus 로고
    • Fractures of the femur after hip replacement
    • CP Duncan BA Masri 1996 Fractures of the femur after hip replacement Instr Course Lect. 44 293 304
    • (1996) Instr Course Lect. , vol.44 , pp. 293-304
    • Duncan, C.P.1    Masri, B.A.2
  • 6
    • 33751018574 scopus 로고    scopus 로고
    • Der minimalinvasive Hüftgelenkersatz in Rückenlage mit hochgelagertem kontralateralem Bein
    • DOI 10.1007/s00064-006-1180-4
    • R Graf M Azizbaig-Mohajer 2006 Minimally invasive total hip replacement with the patient in the supine position and the contralateral leg elevated Oper Orthop Traumatol. 18 317 329 10.1007/s00064-006-1180-4 17103130 (Pubitemid 44742300)
    • (2006) Operative Orthopadie und Traumatologie , vol.18 , Issue.4 , pp. 317-329
    • Azizbaig-Mohajer, M.1    Graf, R.2
  • 7
    • 0037852062 scopus 로고    scopus 로고
    • Principles of management and results of treating the fractured femur during and after total hip arthroplasty
    • 12690859
    • NV Greidanus PA Mitchell BA Masri DS Garbuz CP Duncan 2003 Principles of management and results of treating the fractured femur during and after total hip arthroplasty Instr Course Lect. 52 309 322 12690859
    • (2003) Instr Course Lect. , vol.52 , pp. 309-322
    • Greidanus, N.V.1    Mitchell, P.A.2    Masri, B.A.3    Garbuz, D.S.4    Duncan, C.P.5
  • 8
    • 0026602171 scopus 로고
    • Prophylactic cerclage: A method of preventing femur fracture in uncemented total hip arthroplasty
    • 1:STN:280:DyaK387ltVejtw%3D%3D 1738716
    • PJ Herzwurm J Walch KA Pettine FR Ebert 1992 Prophylactic cerclage: a method of preventing femur fracture in uncemented total hip arthroplasty Orthopedics. 15 143 146 1:STN:280:DyaK387ltVejtw%3D%3D 1738716
    • (1992) Orthopedics. , vol.15 , pp. 143-146
    • Herzwurm, P.J.1    Walch, J.2    Pettine, K.A.3    Ebert, F.R.4
  • 10
    • 0031704870 scopus 로고    scopus 로고
    • Hip arthroplasty: Management problems; Periprosthetic fractures associated with total hip arthroplasty
    • 1:STN:280:DyaK1cvjvF2ktQ%3D%3D 9769041
    • RF Kyle GE Crickard 1998 Hip arthroplasty: management problems; periprosthetic fractures associated with total hip arthroplasty Orthopedics. 21 982 984 1:STN:280:DyaK1cvjvF2ktQ%3D%3D 9769041
    • (1998) Orthopedics. , vol.21 , pp. 982-984
    • Kyle, R.F.1    Crickard, G.E.2
  • 13
    • 30344448619 scopus 로고    scopus 로고
    • Risk factors for intraoperative femoral fractures during total hip replacement
    • 1:STN:280:DC%2BD3M%2Fksl2qsA%3D%3D 10905677
    • A Moroni C Faldini F Piras S Giannini 2000 Risk factors for intraoperative femoral fractures during total hip replacement Ann Chir Gynaecol. 89 113 118 1:STN:280:DC%2BD3M%2Fksl2qsA%3D%3D 10905677
    • (2000) Ann Chir Gynaecol. , vol.89 , pp. 113-118
    • Moroni, A.1    Faldini, C.2    Piras, F.3    Giannini, S.4
  • 14
    • 0031228973 scopus 로고    scopus 로고
    • Hip arthroplasty: Management problems; Periprosthetic fractures: Early and late
    • MD Reis 1997 Hip arthroplasty: management problems; periprosthetic fractures: early and late Orthopedics. 20 789 800
    • (1997) Orthopedics. , vol.20 , pp. 789-800
    • Reis, M.D.1
  • 15
    • 33749431693 scopus 로고    scopus 로고
    • A Clinical, Radiographic, and Cost Comparison of Cerclage Techniques: Wires vs Cables
    • DOI 10.1016/j.arth.2006.01.002, PII S0883540306000088
    • MA Ritter JD Lutgring KE Davis ME Berend JB Meding 2006 A clinical, radiographic, and cost comparison of cerclage techniques: wires vs cables J Arthroplasty. 21 1064 1067 10.1016/j.arth.2006.01.002 17027552 (Pubitemid 44508653)
    • (2006) Journal of Arthroplasty , vol.21 , Issue.7 , pp. 1064-1067
    • Ritter, M.A.1    Lutgring, J.D.2    Davis, K.E.3    Berend, M.E.4    Meding, J.B.5
  • 16
    • 0036193465 scopus 로고    scopus 로고
    • Periprosthetic fractures of the femur
    • DOI 10.1016/S0030-5898(03)00077-4
    • AH Schmidt RF Kyle 2002 Periprosthetic fractures of the femur Orthop Clin. 33 143 152 10.1016/S0030-5898(03)00077-4 (Pubitemid 34204856)
    • (2002) Orthopedic Clinics of North America , vol.33 , Issue.1 , pp. 143-152
    • Schmidt, A.H.1    Kyle, R.F.2
  • 17
    • 0029556970 scopus 로고
    • Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous coated femoral components
    • 10.1016/S0883-5403(05)80082-8 1:STN:280:DyaK28zls1Cqsg%3D%3D 8749768
    • SF Schutzer J Grady-Benson M Jasty DO O'Connor C Bragdon WH Harris 1995 Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous coated femoral components J Arthroplasty. 10 823 829 10.1016/S0883-5403(05)80082-8 1:STN:280:DyaK28zls1Cqsg%3D%3D 8749768
    • (1995) J Arthroplasty. , vol.10 , pp. 823-829
    • Schutzer, S.F.1    Grady-Benson, J.2    Jasty, M.3    O'Connor, D.O.4    Bragdon, C.5    Harris, W.H.6
  • 18
    • 0024456162 scopus 로고
    • Femoral fracture during non-cemented total hip arthroplasty
    • 2777839
    • JT Schwartz Jr JG Mayer CA Engh 1989 Femoral fracture during non-cemented total hip arthroplasty J Bone Joint Surg Am. 71 1135 1142 2777839
    • (1989) J Bone Joint Surg Am. , vol.71 , pp. 1135-1142
    • Schwartz Jr., J.T.1    Mayer, J.G.2    Engh, C.A.3
  • 19
    • 0016832358 scopus 로고
    • Femoral fractures in conjunction with total hip replacement
    • 1:STN:280:DyaE2M7ovFGgsA%3D%3D 1141259
    • RD Scott RH Turner SM Leitzes OE Aufranc 1975 Femoral fractures in conjunction with total hip replacement J Bone Joint Surg Am. 57 494 501 1:STN:280:DyaE2M7ovFGgsA%3D%3D 1141259
    • (1975) J Bone Joint Surg Am. , vol.57 , pp. 494-501
    • Scott, R.D.1    Turner, R.H.2    Leitzes, S.M.3    Aufranc, O.E.4
  • 20
    • 0026650239 scopus 로고
    • Intraoperative femoral fractures in cementless total hip arthroplasty
    • 1:STN:280:DyaK383ivVGrtw%3D%3D 1565523
    • PF Sharkey WJ Hozack RE Booth Jr RH Rothman 1992 Intraoperative femoral fractures in cementless total hip arthroplasty Orthop Rev. 21 337 342 1:STN:280:DyaK383ivVGrtw%3D%3D 1565523
    • (1992) Orthop Rev. , vol.21 , pp. 337-342
    • Sharkey, P.F.1    Hozack, W.J.2    Booth Jr., R.E.3    Rothman, R.H.4
  • 21
    • 0028186551 scopus 로고
    • Incidence of intraoperative femoral fracture. Straight-stemmed versus anatomic cementless total hip arthroplasty
    • 1:STN:280:DyaK2c3isF2ntg%3D%3D 8171987
    • A Toni D Ciaroni A Sudanese F Femino MD Marraro AL Bueno Lozano A Giunti 1994 Incidence of intraoperative femoral fracture. Straight-stemmed versus anatomic cementless total hip arthroplasty Acta Orthop Belg. 60 43 54 1:STN:280:DyaK2c3isF2ntg%3D%3D 8171987
    • (1994) Acta Orthop Belg. , vol.60 , pp. 43-54
    • Toni, A.1    Ciaroni, D.2    Sudanese, A.3    Femino, F.4    Marraro, M.D.5    Bueno Lozano, A.L.6    Giunti, A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.