메뉴 건너뛰기




Volumn 39, Issue 7, 2010, Pages 701-705

Computed tomography fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures

Author keywords

Computed tomography fluoroscopy; Fracture; Pelvis; Screw fixation

Indexed keywords

ADULT; AGED; ARTICLE; BONE SCREW; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FLUOROSCOPY; FRACTURE HEALING; HUMAN; MALE; OPERATION DURATION; PATIENT SAFETY; PELVIS FRACTURE; PELVIS INJURY; PEROPERATIVE COMPLICATION; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SACROILIAC JOINT; VERTEBRA BODY; CLINICAL TRIAL; DEVICES; ILIAC BONE; MIDDLE AGED; OSTEOSYNTHESIS; PELVIC GIRDLE; PROCEDURES; PROSTHESIS IMPLANTATION; RADIOGRAPHY; SACRUM; SURGERY; TREATMENT OUTCOME;

EID: 77955555558     PISSN: 03642348     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00256-009-0826-3     Document Type: Article
Times cited : (15)

References (14)
  • 1
    • 0031266643 scopus 로고    scopus 로고
    • Iliosacral screw fixation: Early complications of the percutaneous technique
    • Routt ML, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma. 1997;11:584-589.
    • (1997) J Orthop Trauma , vol.11 , pp. 584-589
    • Routt, M.L.1    Simonian, P.T.2    Mills, W.J.3
  • 2
    • 0033072966 scopus 로고    scopus 로고
    • Early fixation of the vertically unstable pelvis: The role of iliosacral screw fixation of the posterior lesion
    • Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, O'Brien PJ. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999;13:107-113.
    • (1999) J Orthop Trauma , vol.13 , pp. 107-113
    • Keating, J.F.1    Werier, J.2    Blachut, P.3    Broekhuyse, H.4    Meek, R.N.5    O'Brien, P.J.6
  • 3
    • 0037397651 scopus 로고    scopus 로고
    • Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerized tomography
    • Ziran BH, Smith WR, Towers J, Morgan SJ. Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerized tomography. J Bone Joint Surg Br. 2003;85:411-418.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 411-418
    • Ziran, B.H.1    Smith, W.R.2    Towers, J.3    Morgan, S.J.4
  • 5
    • 0030788118 scopus 로고    scopus 로고
    • Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation
    • Jacob AL, Messmer P, Stock K, et al. Posterior pelvic ring fractures: closed reduction and percutaneous CT-guided sacroiliac screw fixation. Cardiovasc Intervent Radiol. 1997;20:285-294.
    • (1997) Cardiovasc Intervent Radiol , vol.20 , pp. 285-294
    • Jacob, A.L.1    Messmer, P.2    Stock, K.3
  • 6
    • 0035668865 scopus 로고    scopus 로고
    • CT guided percutaneous fixation of sacroiliac fractures in trauma patients
    • Blake-Toker A, Hawkins L, Nadalo L, et al. CT guided percutaneous fixation of sacroiliac fractures in trauma patients. J Trauma. 2001;51:1117-1121.
    • (2001) J Trauma , vol.51 , pp. 1117-1121
    • Blake-Toker, A.1    Hawkins, L.2    Nadalo, L.3
  • 7
    • 0035064218 scopus 로고    scopus 로고
    • Benefits and safety of CT fluoroscopy in interventional radiologic procedures
    • Carlson SK, Bender CE, Classic KL, et al. Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology. 2001;219:515-520.
    • (2001) Radiology , vol.219 , pp. 515-520
    • Carlson, S.K.1    Bender, C.E.2    Classic, K.L.3
  • 8
    • 0033042647 scopus 로고    scopus 로고
    • Real-time CT fluoroscopy: Evolution of an interventional tool
    • Daly B, Templeton PA. Real-time CT fluoroscopy: evolution of an interventional tool. Radiology. 1999;211:309-315.
    • (1999) Radiology , vol.211 , pp. 309-315
    • Daly, B.1    Templeton, P.A.2
  • 9
    • 0022521308 scopus 로고
    • Pelvic fractures: Value of plain radiography in early assessment and management
    • Young JW, Burgess AR, Brumback RJ, Poka A. Pelvic fractures: value of plain radiography in early assessment and management. Radiology. 1986;160:445-451.
    • (1986) Radiology , vol.160 , pp. 445-451
    • Young, J.W.1    Burgess, A.R.2    Brumback, R.J.3    Poka, A.4
  • 10
    • 0012513163 scopus 로고    scopus 로고
    • Fracture and dislocation compendium. Orthopaedic trauma association committee for coding and classification
    • Orthopaedic Trauma Association
    • Orthopaedic Trauma Association. Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma. 1996;10(Suppl 1):69.
    • (1996) J Orthop Trauma , vol.10 , Issue.SUPPL. 1 , pp. 69
  • 11
    • 0023529975 scopus 로고
    • Percutaneous computed-tomography-stabilization of pelvic fractures: Preliminary report
    • Ebraheim NA, Rusin JJ, Coombs RJ, Jackson WT, Holiday B. Percutaneous computed-tomography-stabilization of pelvic fractures: preliminary report. J Orthop Trauma. 1987;1:197-204.
    • (1987) J Orthop Trauma , vol.1 , pp. 197-204
    • Ebraheim, N.A.1    Rusin, J.J.2    Coombs, R.J.3    Jackson, W.T.4    Holiday, B.5
  • 12
    • 73149114866 scopus 로고    scopus 로고
    • CT fluoroscopy-guided biopsy of 1000 pulmonary lesions performed with 20-gauge coaxial cutting needles: Diagnostic yield and risk factors for diagnostic failure
    • in press
    • Hiraki T, Mimura H, Gobara H, et al. CT fluoroscopy-guided biopsy of 1000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest (in press).
    • Chest
    • Hiraki, T.1    Mimura, H.2    Gobara, H.3
  • 13
    • 0029832236 scopus 로고    scopus 로고
    • Guidance with real-time CT fluoroscopy: Early clinical experience
    • Katada K, Kato R, Anno H, et al. Guidance with real-time CT fluoroscopy: early clinical experience. Radiology. 1996;200:851-856.
    • (1996) Radiology , vol.200 , pp. 851-856
    • Katada, K.1    Kato, R.2    Anno, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.