메뉴 건너뛰기




Volumn 39, Issue 2, 2010, Pages 194-197

In-flight thoracic ultrasound detection of pneumothorax in combat

Author keywords

aviation medicine; chest tube thoracostomy; medical evacuation; pneumothorax; thoracic ultrasonography

Indexed keywords

ARTICLE; AUSCULTATION; AVIATION; BLAST INJURY; CASE REPORT; ECHOGRAPHY; HEMODYNAMICS; HOSTILITY; HUMAN; MALE; PHYSICAL EXAMINATION; PNEUMOTHORAX; PRIORITY JOURNAL; THORAX DRAINAGE;

EID: 77955553186     PISSN: 07364679     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jemermed.2009.08.026     Document Type: Article
Times cited : (26)

References (16)
  • 4
    • 0025774407 scopus 로고
    • Inability to assess breath sounds during air medical transport by helicopter
    • R.C. Hunt, D.M. Bryan, and S. Brinkley Inability to assess breath sounds during air medical transport by helicopter JAMA 265 1991 1982 1984
    • (1991) JAMA , vol.265 , pp. 1982-1984
    • Hunt, R.C.1    Bryan, D.M.2    Brinkley, S.3
  • 5
    • 41149105716 scopus 로고    scopus 로고
    • Focused assessment by sonography in trauma during emergency retrieval: A feasibility study
    • The F.A.S.T.E.R. trial
    • S. Mazur, A. Pearce, S. Alfred The F.A.S.T.E.R. trial Focused assessment by sonography in trauma during emergency retrieval: a feasibility study Injury 39 2008 512 518
    • (2008) Injury , vol.39 , pp. 512-518
    • Mazur, S.1    Pearce, A.2    Alfred, S.3
  • 6
    • 0034293001 scopus 로고    scopus 로고
    • Trauma ultrasound feasibility during helicopter transport
    • D.D. Price, S.R. Wilson, and T.G. Murphy Trauma ultrasound feasibility during helicopter transport Air Med J 19 2000 144 146
    • (2000) Air Med J , vol.19 , pp. 144-146
    • Price, D.D.1    Wilson, S.R.2    Murphy, T.G.3
  • 7
    • 0035039253 scopus 로고    scopus 로고
    • The "airmedical F.A.S.T." for trauma patientsthe initial report of a novel application for sonography
    • J.D. Polk, W.F. Fallon Jr, and B. Kovach The "Airmedical F.A.S.T." for trauma patientsthe initial report of a novel application for sonography Aviat Space Environ Med 72 2001 432 436
    • (2001) Aviat Space Environ Med , vol.72 , pp. 432-436
    • Polk, J.D.1    Fallon Jr., W.F.2    Kovach, B.3
  • 8
    • 0034793468 scopus 로고    scopus 로고
    • Aeromedical trauma sonography by flight crews with a miniature ultrasound unit
    • S.W. Melanson, J. McCarthy, and C.J. Stromski Aeromedical trauma sonography by flight crews with a miniature ultrasound unit Prehosp Emerg Care 5 2001 399 402
    • (2001) Prehosp Emerg Care , vol.5 , pp. 399-402
    • Melanson, S.W.1    McCarthy, J.2    Stromski, C.J.3
  • 9
    • 34447641451 scopus 로고    scopus 로고
    • Rapid detection of pneumothorax by ultrasonography in patients with multiple trauma
    • M. Zhang, Z.H. Liu, and J.X. Yang Rapid detection of pneumothorax by ultrasonography in patients with multiple trauma Crit Care 10 2006 R112
    • (2006) Crit Care , vol.10 , pp. 112
    • Zhang, M.1    Liu, Z.H.2    Yang, J.X.3
  • 10
    • 23944521630 scopus 로고    scopus 로고
    • A Prospective comparison of supine chest radiography and bedside ultrasound for the diagnosis of traumatic pneumothorax
    • M. Blaivas, M. Lyon, and S. Duggal A Prospective comparison of supine chest radiography and bedside ultrasound for the diagnosis of traumatic pneumothorax Acad Emerg Med 12 2005 844 849
    • (2005) Acad Emerg Med , vol.12 , pp. 844-849
    • Blaivas, M.1    Lyon, M.2    Duggal, S.3
  • 11
    • 38349076400 scopus 로고    scopus 로고
    • Occult traumatic pneumothorax diagnostic accuracy of lung ultrasonography in the emergency department
    • G. Soldati, A. Testa, and S. Sher Occult traumatic pneumothorax diagnostic accuracy of lung ultrasonography in the emergency department Chest 133 2008 204 211
    • (2008) Chest , vol.133 , pp. 204-211
    • Soldati, G.1    Testa, A.2    Sher, S.3
  • 12
    • 33749018539 scopus 로고    scopus 로고
    • Use of ultrasonography to avoid an unnecessary procedure in the prehospital combat environment: A case report
    • J.R. Do, J. McManus, and B. Harrison Use of ultrasonography to avoid an unnecessary procedure in the prehospital combat environment: a case report Prehosp Emerg Care 10 2006 502 506
    • (2006) Prehosp Emerg Care , vol.10 , pp. 502-506
    • Do, J.R.1    McManus, J.2    Harrison, B.3
  • 13
    • 12144280572 scopus 로고    scopus 로고
    • The potential of handheld sonography in the air medical transport of the trauma victim
    • A. Kirkpatrick, K. Breeck, and J. Wong The potential of handheld sonography in the air medical transport of the trauma victim Air Med J 24 2005 34 39
    • (2005) Air Med J , vol.24 , pp. 34-39
    • Kirkpatrick, A.1    Breeck, K.2    Wong, J.3
  • 14
    • 77955558548 scopus 로고    scopus 로고
    • Feasibility of using M-mode ultrasound for the detection of pneumothorax during helicopter transport
    • M. Lyon, P. Walton, and C. Fly Feasibility of using M-mode ultrasound for the detection of pneumothorax during helicopter transport Ann Emerg Med 52 2008 S147
    • (2008) Ann Emerg Med , vol.52 , pp. 147
    • Lyon, M.1    Walton, P.2    Fly, C.3
  • 15
    • 36248947905 scopus 로고    scopus 로고
    • Use of point-of-care ultrasound by a critical care retrieval team
    • S. Mazur, A. Pearce, and S. Alfred Use of point-of-care ultrasound by a critical care retrieval team Emerg Med Australas 19 2007 547 552
    • (2007) Emerg Med Australas , vol.19 , pp. 547-552
    • Mazur, S.1    Pearce, A.2    Alfred, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.