메뉴 건너뛰기




Volumn , Issue , 2005, Pages 85-89

Surface damage and wear in fixed, modular tibial inserts: The effects of conformity and constraint

Author keywords

[No Author keywords available]

Indexed keywords


EID: 77955550316     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1007/3-540-27658-0_13     Document Type: Chapter
Times cited : (3)

References (20)
  • 2
    • 0036898690 scopus 로고    scopus 로고
    • Osteolysis in failed total knee arthroplasty: A comparison of mobile-bearing and fixed-bearing knees
    • Huang CH et al (2002) Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees. J Bone Joint Surg [Am] 84:2224-2229
    • (2002) J Bone Joint Surg [Am] , vol.84 , pp. 2224-2229
    • Huang, C.H.1
  • 3
    • 0020826593 scopus 로고
    • Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses
    • Hood RW et al (1983) Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res 17:829-842 (Pubitemid 14225818)
    • (1983) Journal of Biomedical Materials Research , vol.17 , Issue.5 , pp. 829-842
    • Hood, R.W.1    Wright, T.M.2    Burstein, A.H.3
  • 4
    • 84981422019 scopus 로고
    • Kunststoffe in der Gelenkendoprothetik
    • Eyerer P (1986) Kunststoffe in der Gelenkendoprothetik. Z Werk-stofftechnik 17:284
    • (1986) Z Werk-stofftechnik , vol.17 , pp. 284
    • Eyerer, P.1
  • 5
    • 0001872604 scopus 로고    scopus 로고
    • Effect of resin type and manufacturing method on UHMWPE oxidation and quality at long aging and implant times
    • Furman B et al (1997) Effect of resin type and manufacturing method on UHMWPE oxidation and quality at long aging and implant times. Trans of 43rd Annual Meeting of the Orthopaedic Research Society
    • (1997) Trans of 43rd Annual Meeting of the Orthopaedic Research Society
    • Furman, B.1
  • 6
    • 0031105323 scopus 로고    scopus 로고
    • Polyethylene wear in total hip and knee arthroplasties
    • DOI 10.1002/(SICI)1097-4636(199721)38:1<55::AID-JBM8>3.0.CO;2-G
    • Lewis G (1997) Polyethylene wear in total hip and knee arthroplasties. J Biomed Mater Res 38:55-75 (Pubitemid 27131063)
    • (1997) Journal of Biomedical Materials Research , vol.38 , Issue.1 , pp. 55-75
    • Lewis, G.1
  • 10
    • 0036901564 scopus 로고    scopus 로고
    • In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty
    • DOI 10.1054/arth.2002.35793
    • Bertin KC et al (2002) In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty. J Arthroplasty 17:1040-1048 (Pubitemid 35462948)
    • (2002) Journal of Arthroplasty , vol.17 , Issue.8 , pp. 1040-1048
    • Bertin, K.C.1    Komistek, R.D.2    Dennis, D.A.3    Hoff, W.A.4    Anderson, D.T.5    Langer, T.6
  • 11
    • 0035217069 scopus 로고    scopus 로고
    • Cruciate-retaining and cruciate-substituting total knee arthroplasty: An in vitro comparison of the kinematics under muscle Loads
    • DOI 10.1054/arth.2001.28367
    • Li G et al (2001) Cruciate-retaining and cruciate-substituting total knee arthroplasty: an in vitro comparison of the kinematics under muscle loads. J Arthroplasty 16 [Suppl 1]:150-156 (Pubitemid 33151063)
    • (2001) Journal of Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 150-156
    • Li, G.1    Zayontz, S.2    Most, E.3    Otterberg, E.4    Sabbag, K.5    Rubash, H.E.6
  • 12
    • 0023815239 scopus 로고
    • Retention of the posterior cruciate in total knee arthroplasty
    • Andriacchi TP, Galante JO (1988) Retention of the posterior cruciate in total knee arthroplasty. J Arthroplasty 3 [Suppl]:S13-19
    • (1988) J Arthroplasty , vol.3 , Issue.SUPPL.
    • Andriacchi, T.P.1    Galante, J.O.2
  • 13
    • 0029052864 scopus 로고
    • Stresses in polyethylene components of contemporary total knee replacements
    • Bartel DL et al (1995) Stresses in polyethylene components of contemporary total knee replacements. Clin Orthop 317:76-82
    • (1995) Clin Orthop , vol.317 , pp. 76-82
    • Bartel, D.L.1
  • 16
    • 0026346472 scopus 로고
    • Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
    • Collier JP et al (1991) Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 273:232-242
    • (1991) Clin Orthop , vol.273 , pp. 232-242
    • Collier, J.P.1
  • 17
  • 18
    • 0026655386 scopus 로고
    • Polyethylene wear in unicondylar knee prostheses. 106 retrieved Marmor, PCA, and St. Georg tibial components compared
    • Blunn GW et al (1992) Polyethylene wear in unicondylar knee prostheses. 106 retrieved Marmor, PCA, and St. Georg tibial components compared. Acta Orthop Scand 63:247-255
    • (1992) Acta Orthop Scand , vol.63 , pp. 247-255
    • Blunn, G.W.1
  • 19
    • 0028838566 scopus 로고
    • Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement
    • Ritter MA et al (1995) Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement. Clin Orthop 321:79-85
    • (1995) Clin Orthop , vol.321 , pp. 79-85
    • Ritter, M.A.1
  • 20
    • 84892133122 scopus 로고    scopus 로고
    • Effect of contact area on the wear of ultrahigh molecular weight polyethylene in bidirectional pin-on-flat articulation
    • Mazzucco D, Spector M (2003) Effect of contact area on the wear of ultrahigh molecular weight polyethylene in bidirectional pin-on-flat articulation. Trans of 49th Annual Meeting of the Orthopedic Research Society 28:1
    • (2003) Trans of 49th Annual Meeting of the Orthopedic Research Society , vol.28 , pp. 1
    • Mazzucco, D.1    Spector, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.