메뉴 건너뛰기




Volumn 3, Issue 2, 2010, Pages 159-164

The perturbation correction factors for cylindrical ionization chambers in high-energy photon beams

Author keywords

Cylindrical ionization chamber; Dosimetry; Monte Carlo simulation; Perturbation correction factor

Indexed keywords

ALUMINUM; COBALT 60; GRAPHITE;

EID: 77955518873     PISSN: 18650333     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12194-010-0091-0     Document Type: Article
Times cited : (6)

References (15)
  • 1
    • 0003680967 scopus 로고    scopus 로고
    • Absorbed dose determination in external beam radiotherapy
    • IAEA Vienna: IAEA
    • IAEA. Absorbed dose determination in external beam radiotherapy. Technical Report Series 398. Vienna: IAEA; 2000.
    • (2000) Technical Report Series , vol.398
  • 2
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • DOI 10.1118/1.598691
    • PR Almond PJ Biggs BM Coursey WF Hanson MS Huq R Nath, et al. 1999 AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams Med Phys 26 1847 1870 10.1118/1.598691 1:STN:280: DyaK1MvjtlKqsQ%3D%3D (Pubitemid 29442268)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.O.7
  • 3
    • 0019137194 scopus 로고
    • Displacement corrections used in absorbed dose determination
    • DOI 10.1118/1.594817
    • JR Cunningham MR Sontag 1980 Displacement corrections used in absorbed dose determination Med Phys 7 672 676 10.1118/1.594817 1:STN:280: DyaL3M7it1Ckuw%3D%3D (Pubitemid 11196062)
    • (1980) Medical Physics , vol.7 , Issue.6 , pp. 672-676
    • Cunningham, J.R.1    Sontag, M.R.2
  • 5
    • 42949146907 scopus 로고    scopus 로고
    • Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation
    • DOI 10.1118/1.2898139
    • LLW Wang DWO Rogers 2008 Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation Med Phys 35 1747 1755 10.1118/1.2898139 1:CAS:528:DC%2BD1cXltlGjs74%3D (Pubitemid 351614788)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 1747-1755
    • Wang, L.L.W.1    Rogers, D.W.O.2
  • 9
    • 84907108726 scopus 로고
    • Ionization chamber dosimetry for photon and electron beams Theoretical considerations
    • Almond PR, Svensson H. Ionization chamber dosimetry for photon and electron beams Theoretical considerations. Acta Radiol Ther Phys Biol. 1977;16:177.
    • (1977) Acta Radiol Ther Phys Biol. , vol.16 , pp. 177
    • Almond, P.R.1    Svensson, H.2
  • 10
    • 0027535624 scopus 로고
    • Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams
    • 10.1088/0031-9155/38/2/005
    • CM Ma AE Nahum 1922 Effect of size and composition of the central electrode on the response of cylindrical ionization chambers in high-energy photon and electron beams Phys Med Biol 38 267 290 10.1088/0031-9155/38/2/005
    • (1922) Phys Med Biol , vol.38 , pp. 267-290
    • Ma, C.M.1    Nahum, A.E.2
  • 11
    • 45749111374 scopus 로고    scopus 로고
    • Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams
    • DOI 10.1088/0031-9155/53/11/005, PII S0031915508724370
    • J Wulff JT Heverhagen K Zink 2008 Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams Phys Med Biol 53 2823 2836 10.1088/0031-9155/53/11/005 1:STN:280:DC%2BD1cvitVagsA%3D%3D (Pubitemid 351868608)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11 , pp. 2823-2836
    • Wulff, J.1    Heverhagen, J.T.2    Zink, K.3
  • 12
    • 63649111792 scopus 로고    scopus 로고
    • Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors
    • 10.1118/1.3115982 1:STN:280:DC%2BD1MvjsFKguw%3D%3D
    • LLW Wang DJL Russa DWO Rogers 2009 Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors Med Phys 36 1785 1789 10.1118/1.3115982 1:STN:280:DC%2BD1MvjsFKguw%3D%3D
    • (2009) Med Phys , vol.36 , pp. 1785-1789
    • Wang, L.L.W.1    Russa, D.J.L.2    Rogers, D.W.O.3
  • 13
    • 0032717811 scopus 로고    scopus 로고
    • 60Co therapy source
    • 10.1118/1.598770 1:STN:280:DC%2BD3c%2Flt1GhsA%3D%3D
    • 60Co therapy source Med Phys 26 2494 2502 10.1118/1.598770 1:STN:280:DC%2BD3c%2Flt1GhsA%3D%3D
    • (1999) Med Phys , vol.26 , pp. 2494-2502
    • Mora, G.M.1    Maio, A.2    Rogers, D.W.O.3
  • 14
    • 0034023628 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations
    • DOI 10.1118/1.598918
    • I Kawrakow 2000 Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations Med Phys 27 499 513 10.1118/1.598918 1:CAS:528:DC%2BD3cXisFWntLw%3D (Pubitemid 30171798)
    • (2000) Medical Physics , vol.27 , Issue.3 , pp. 499-513
    • Kawrakow, I.1
  • 15
    • 31844450298 scopus 로고    scopus 로고
    • wall, for thimble ionization chambers
    • DOI 10.1118/1.2161403
    • wall, for thimble ionization chambers Med Phys 33 455 464 10.1118/1.2161403 (Pubitemid 43183990)
    • (2006) Medical Physics , vol.33 , Issue.2 , pp. 455-464
    • Buckley, L.A.1    Rogers, D.W.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.