메뉴 건너뛰기




Volumn 76, Issue 1, 2010, Pages 56-59

Point-of-use filtration method for the prevention of fungal contamination of hospital water

Author keywords

Filamentous fungi; Hospital infection; Point of use filters; Water supply

Indexed keywords

ARTICLE; ASPERGILLUS FUMIGATUS; COLONY FORMING UNIT; FILTER; FILTRATION; FUNGUS; HOSPITAL DEPARTMENT; NONHUMAN; SIMULATION; WATER CONTAMINATION; WATER SUPPLY; WATER TREATMENT;

EID: 77955513315     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2010.03.014     Document Type: Article
Times cited : (24)

References (13)
  • 1
    • 0035117474 scopus 로고    scopus 로고
    • Recovery of filamentous fungi from water in a paediatric bone marrow transplantation unit
    • Warris A., Gaustad P., Meis J.F., Voss A., Verweij P.E., Abrahamsen T.G. Recovery of filamentous fungi from water in a paediatric bone marrow transplantation unit. J Hosp Infect 2001, 47:143-148.
    • (2001) J Hosp Infect , vol.47 , pp. 143-148
    • Warris, A.1    Gaustad, P.2    Meis, J.F.3    Voss, A.4    Verweij, P.E.5    Abrahamsen, T.G.6
  • 2
    • 0041419052 scopus 로고    scopus 로고
    • Molecular epidemiology of Aspergillus fumigatus isolates recovered from water, air, and patients shows two clusters of genetically distinct strains
    • Warris A., Klaassen C.H., Meis J.F., et al. Molecular epidemiology of Aspergillus fumigatus isolates recovered from water, air, and patients shows two clusters of genetically distinct strains. J Clin Microbiol 2003, 41:4101-4106.
    • (2003) J Clin Microbiol , vol.41 , pp. 4101-4106
    • Warris, A.1    Klaassen, C.H.2    Meis, J.F.3
  • 3
    • 0037087045 scopus 로고    scopus 로고
    • Pathogenic Aspergillus species recovered from a hospital water system: a 3-year prospective study
    • Anaissie E.J., Stratton S.L., Dignani M.C., et al. Pathogenic Aspergillus species recovered from a hospital water system: a 3-year prospective study. Clin Infect Dis 2002, 34:780-790.
    • (2002) Clin Infect Dis , vol.34 , pp. 780-790
    • Anaissie, E.J.1    Stratton, S.L.2    Dignani, M.C.3
  • 4
    • 77955510173 scopus 로고    scopus 로고
    • Is nosocomial aspergillosis waterborne?
    • Warris A. Is nosocomial aspergillosis waterborne?. Filtration 2005, 1:3-8.
    • (2005) Filtration , vol.1 , pp. 3-8
    • Warris, A.1
  • 6
    • 0037090138 scopus 로고    scopus 로고
    • Contamination of hospital water with Aspergillus fumigatus and other molds
    • Warris A., Voss A., Abrahamsen T.G., Verweij P.E. Contamination of hospital water with Aspergillus fumigatus and other molds. Clin Infect Dis 2002, 34:1159-1160.
    • (2002) Clin Infect Dis , vol.34 , pp. 1159-1160
    • Warris, A.1    Voss, A.2    Abrahamsen, T.G.3    Verweij, P.E.4
  • 7
    • 0034122501 scopus 로고    scopus 로고
    • Nosocomial Legionnaire's disease in a children's hospital
    • Campins M., Ferrer A., Callis L., et al. Nosocomial Legionnaire's disease in a children's hospital. Ped Infect Dis J 2000, 19:223-224.
    • (2000) Ped Infect Dis J , vol.19 , pp. 223-224
    • Campins, M.1    Ferrer, A.2    Callis, L.3
  • 8
    • 17844370801 scopus 로고    scopus 로고
    • Use of terminal tap water filter systems for prevention of nosocomial legionellosis
    • Vonberg R.P., Eckmanns T., Bruderek J., Ruden H., Gastmeier P. Use of terminal tap water filter systems for prevention of nosocomial legionellosis. J Hosp Infect 2005, 60:159-162.
    • (2005) J Hosp Infect , vol.60 , pp. 159-162
    • Vonberg, R.P.1    Eckmanns, T.2    Bruderek, J.3    Ruden, H.4    Gastmeier, P.5
  • 9
    • 22144479076 scopus 로고    scopus 로고
    • Efficacy of new point-of-use water filter for preventing exposure to Legionella and waterborne bacteria
    • Sheffer P.J., Stout J.E., Wagener M.M., Muder R.R. Efficacy of new point-of-use water filter for preventing exposure to Legionella and waterborne bacteria. Am J Infect Control 2005, 33(5 Suppl. 1):S20-25.
    • (2005) Am J Infect Control , vol.33 , Issue.5 SUPPL. 1
    • Sheffer, P.J.1    Stout, J.E.2    Wagener, M.M.3    Muder, R.R.4
  • 10
    • 0036779614 scopus 로고    scopus 로고
    • Pseudomonas aeruginosa outbreak in a hematology oncology unit associated with contaminated surface cleaning equipment
    • Engelhart S., Krizek I., Glasmacher A., Fischnaller E., Marklein G., Exner M. Pseudomonas aeruginosa outbreak in a hematology oncology unit associated with contaminated surface cleaning equipment. J Hosp Infect 2002, 52:93-98.
    • (2002) J Hosp Infect , vol.52 , pp. 93-98
    • Engelhart, S.1    Krizek, I.2    Glasmacher, A.3    Fischnaller, E.4    Marklein, G.5    Exner, M.6
  • 11
    • 0037043239 scopus 로고    scopus 로고
    • The hospital water supply as a source of nosocomial infections. A plea for action
    • Anaissie E.J., Penzak S.R., Dignani M.C. The hospital water supply as a source of nosocomial infections. A plea for action. Arch Intern Med 2002, 162:1483-1492.
    • (2002) Arch Intern Med , vol.162 , pp. 1483-1492
    • Anaissie, E.J.1    Penzak, S.R.2    Dignani, M.C.3
  • 13
    • 48049104380 scopus 로고    scopus 로고
    • Point-of-use water filtration reduces endemic Pseudomonas aeruginosa infections on a surgical intensive care unit
    • Trautmann M., Halder S., Hoegel J., Royer H., Haller M. Point-of-use water filtration reduces endemic Pseudomonas aeruginosa infections on a surgical intensive care unit. Am J Infect Control 2008, 36:421-429.
    • (2008) Am J Infect Control , vol.36 , pp. 421-429
    • Trautmann, M.1    Halder, S.2    Hoegel, J.3    Royer, H.4    Haller, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.