메뉴 건너뛰기




Volumn 30, Issue 14-15, 2010, Pages 2116-2126

Optimal design of effluent-cooling systems using a mathematical programming model

Author keywords

Aqueous effluents; Cooling system; Cooling tower; MINLP; Optimization; Thermal treatment

Indexed keywords

AQUEOUS EFFLUENT; AQUEOUS EFFLUENTS; CAPITAL COSTS; DESIGN PARAMETERS; DETAILED MODELS; DISCHARGE TEMPERATURE; MATHEMATICAL PROGRAMMING MODELS; MIXED INTEGER NON-LINEAR PROGRAMMING PROBLEMS; OPTIMAL COOLING; OPTIMAL DESIGN; OPTIMAL OPERATING CONDITIONS; POWER CONSUMPTION; SYSTEM CONFIGURATIONS; THERMAL TREATMENT; TOTAL ANNUAL COSTS; WATER PUMP;

EID: 77955472792     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2010.05.021     Document Type: Article
Times cited : (18)

References (36)
  • 1
    • 0035799254 scopus 로고    scopus 로고
    • Design of cooling systems for effluent temperature reduction
    • J. Kim, L. Savulescu, and R. Smith Design of cooling systems for effluent temperature reduction Chemical Engineering Science 56 5 2001 1811 1830
    • (2001) Chemical Engineering Science , vol.56 , Issue.5 , pp. 1811-1830
    • Kim, J.1    Savulescu, L.2    Smith, R.3
  • 2
    • 0035927533 scopus 로고    scopus 로고
    • Cooling water system design
    • J. Kim, and R. Smith Cooling water system design Chemical Engineering Science 56 12 2001 3641 3658
    • (2001) Chemical Engineering Science , vol.56 , Issue.12 , pp. 3641-3658
    • Kim, J.1    Smith, R.2
  • 8
    • 34047184251 scopus 로고    scopus 로고
    • Superstructure-based MINLP formulation for synthesis of re-circulating cooling-water networks with intermediate mains
    • C.L. Chen, L.F. Lin, Y.J. Ciou, and W.C. Chen Superstructure-based MINLP formulation for synthesis of re-circulating cooling-water networks with intermediate mains Journal of Chemical Engineering of Japan 40 3 2007 235 243
    • (2007) Journal of Chemical Engineering of Japan , vol.40 , Issue.3 , pp. 235-243
    • Chen, C.L.1    Lin, L.F.2    Ciou, Y.J.3    Chen, W.C.4
  • 9
    • 77953550196 scopus 로고    scopus 로고
    • Application of ozone treatment and pinch technology in cooling water systems for water and energy conservation
    • A. Ataei, M. Gharaie, R. Parand, and M.H. Panjeshahi Application of ozone treatment and pinch technology in cooling water systems for water and energy conservation International Journal of Energy Research 34 6 2010 494 506
    • (2010) International Journal of Energy Research , vol.34 , Issue.6 , pp. 494-506
    • Ataei, A.1    Gharaie, M.2    Parand, R.3    Panjeshahi, M.H.4
  • 10
    • 33846527298 scopus 로고    scopus 로고
    • Simplified model for the determination of the steady state response of cooling systems
    • M. Picón-Nuñez, C. Nila-Gasca, and A. Morales-Fuentes Simplified model for the determination of the steady state response of cooling systems Applied Thermal Engineering 27 7 2007 1173 1181
    • (2007) Applied Thermal Engineering , vol.27 , Issue.7 , pp. 1173-1181
    • Picón-Nuñez, M.1    Nila-Gasca, C.2    Morales-Fuentes, A.3
  • 11
    • 33744974991 scopus 로고    scopus 로고
    • A complete model of wet cooling towers with fouling in fills
    • B.A. Qureshi, and S.M. Zubair A complete model of wet cooling towers with fouling in fills Applied Thermal Engineering 26 16 2006 1982 1989
    • (2006) Applied Thermal Engineering , vol.26 , Issue.16 , pp. 1982-1989
    • Qureshi, B.A.1    Zubair, S.M.2
  • 13
    • 0342468998 scopus 로고    scopus 로고
    • On the optimum sizing of cooling towers
    • M.S. Söylemez On the optimum sizing of cooling towers Energy Conversion and Management 42 7 2001 783 789
    • (2001) Energy Conversion and Management , vol.42 , Issue.7 , pp. 783-789
    • Söylemez, M.S.1
  • 14
    • 2442670566 scopus 로고    scopus 로고
    • On the optimum performance of forced draft counter flow cooling towers
    • M.S. Söylemez On the optimum performance of forced draft counter flow cooling towers Energy Conversion and Management 45 15-16 2004 2335 2341
    • (2004) Energy Conversion and Management , vol.45 , Issue.1516 , pp. 2335-2341
    • Söylemez, M.S.1
  • 18
    • 3142603394 scopus 로고    scopus 로고
    • Heat and mass transfer correlations for the design of small indirect contact cooling towers
    • J. Facão, and A. Oliveira Heat and mass transfer correlations for the design of small indirect contact cooling towers Applied Thermal Engineering 24 14-15 2004 1969 1978
    • (2004) Applied Thermal Engineering , vol.24 , Issue.1415 , pp. 1969-1978
    • Facão, J.1    Oliveira, A.2
  • 19
    • 0033990077 scopus 로고    scopus 로고
    • The investigation of cooling tower packing in various arrangements
    • H.R. Goshayshi, and J.F. Messinder The investigation of cooling tower packing in various arrangements Applied Thermal Engineering 20 1 2000 69 80
    • (2000) Applied Thermal Engineering , vol.20 , Issue.1 , pp. 69-80
    • Goshayshi, H.R.1    Messinder, J.F.2
  • 20
    • 33845500525 scopus 로고    scopus 로고
    • Thermal performance investigation of a wet cooling tower
    • M. Lemouari, M. Boumaza, and I.M. Mujtaba Thermal performance investigation of a wet cooling tower Applied Thermal Engineering 27 5-6 2007 902 909
    • (2007) Applied Thermal Engineering , vol.27 , Issue.56 , pp. 902-909
    • Lemouari, M.1    Boumaza, M.2    Mujtaba, I.M.3
  • 23
    • 0141860810 scopus 로고    scopus 로고
    • Loss coefficient correlation for wet-cooling tower fills
    • J.C. Kloppers, and D.G. Kröger Loss coefficient correlation for wet-cooling tower fills Applied Thermal Engineering 23 17 2003 2201 2211
    • (2003) Applied Thermal Engineering , vol.23 , Issue.17 , pp. 2201-2211
    • Kloppers, J.C.1    Kröger, D.G.2
  • 24
    • 17444374312 scopus 로고    scopus 로고
    • Refinement of the transfer characteristic correlation of wet-cooling tower fills
    • J.C. Kloppers, and D.G. Kröger Refinement of the transfer characteristic correlation of wet-cooling tower fills Heat Transfer Engineering 26 4 2005 35 41
    • (2005) Heat Transfer Engineering , vol.26 , Issue.4 , pp. 35-41
    • Kloppers, J.C.1    Kröger, D.G.2
  • 25
    • 0029289014 scopus 로고
    • Cost-optimal design for cooling towers
    • M. Kintner-Meyer, and A.F. Emery Cost-optimal design for cooling towers ASHRAE Journal 37 4 1995 46 55
    • (1995) ASHRAE Journal , vol.37 , Issue.4 , pp. 46-55
    • Kintner-Meyer, M.1    Emery, A.F.2
  • 26
    • 0037443768 scopus 로고    scopus 로고
    • Modeling of discrete/continuous optimization problems characterization and formulation of disjunctions and their relaxations
    • A. Vicchietti, S. Lee, and I.E. Grossmann Modeling of discrete/continuous optimization problems characterization and formulation of disjunctions and their relaxations Computers and Chemical Engineering 27 3 2003 433 448
    • (2003) Computers and Chemical Engineering , vol.27 , Issue.3 , pp. 433-448
    • Vicchietti, A.1    Lee, S.2    Grossmann, I.E.3
  • 27
    • 0029735625 scopus 로고    scopus 로고
    • Knowledge base for the systematic design of wet cooling towers. Part I: Selection and tower characteristics
    • DOI 10.1016/0140-7007(95)00059-3
    • A.K.M. Mohiudding, and K. Kant Knowledge base for the systematic design of wet cooling towers. Part I: selection and tower characteristics International Journal of Refrigeration 19 1 1996 43 51 (Pubitemid 126384976)
    • (1996) International Journal of Refrigeration , vol.19 , Issue.1 , pp. 43-51
    • Mohiuddin, A.K.M.1    Kant, K.2
  • 33
    • 0025459923 scopus 로고
    • A combined penalty function and outer approximation method for MINLP optimization
    • J. Viswanathan, and I.E. Grossmann A combined penalty function and outer approximation method for MINLP optimization Computers and Chemical Engineering 14 7 1990 769 782
    • (1990) Computers and Chemical Engineering , vol.14 , Issue.7 , pp. 769-782
    • Viswanathan, J.1    Grossmann, I.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.