메뉴 건너뛰기




Volumn 7, Issue 4, 2010, Pages 0410041-0410045

The resistive properties of proton exchange membrane fuel cells with stainless steel bipolar plates

Author keywords

Charge transfer; Electrochemical impedance spectroscopy; Mass transport and ohmic resistance

Indexed keywords

AIR SUPPORT; ANTI-CORROSION; BIPOLAR PLATES; CHARGE TRANSFER RESISTANCE; ELECTROCHEMICAL TREATMENTS; HUMIDITY EFFECTS; MASS TRANSPORT; MASS-TRANSPORT RESISTANCE; OHMIC RESISTANCE; ON-RESISTANCE; OPERATING CONDITION; PURE OXYGEN; RESISTANCE VARIATIONS; SINGLE CELLS;

EID: 77955459143     PISSN: 1550624X     EISSN: 15516989     Source Type: Journal    
DOI: 10.1115/1.3179760     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 33845633273 scopus 로고    scopus 로고
    • A flow channel design procedure for PEM fuel cells with effective water removal
    • Li, X., Sabir, I., and Park, J., 2007, "A Flow Channel Design Procedure for PEM Fuel Cells With Effective Water Removal", J. Power Sources, 163, pp. 933-942.
    • (2007) J. Power Sources , vol.163 , pp. 933-942
    • Li, X.1    Sabir, I.2    Park, J.3
  • 2
    • 33845664015 scopus 로고    scopus 로고
    • Metal bipolar plates for PEM fuel cell-A review
    • Tawfik, H., Hung, Y., and Mahajan, D., 2007, "Metal Bipolar Plates for PEM Fuel Cell-A Review", J. Power Sources, 163, pp. 755-767.
    • (2007) J. Power Sources , vol.163 , pp. 755-767
    • Tawfik, H.1    Hung, Y.2    Mahajan, D.3
  • 3
    • 34248574881 scopus 로고    scopus 로고
    • Analytical approach to polymer electrolyte membrane fuel cell performance and optimization
    • Das, P., Li, X., and Liu, Z. S., 2007, "Analytical Approach to Polymer Electrolyte Membrane Fuel Cell Performance and Optimization", J. Electroanal. Chem., 604, pp. 72-90.
    • (2007) J. Electroanal. Chem. , vol.604 , pp. 72-90
    • Das, P.1    Li, X.2    Liu, Z.S.3
  • 4
    • 33748419608 scopus 로고    scopus 로고
    • An analytical solution for transport of oxygen in cathode gas diffusion layer of PEMFC
    • DOI 10.1016/j.jpowsour.2006.01.019, PII S0378775306000863
    • Tsai, C. R., Chen, F., Ruoa, A. C, Chang, M. H., Chu, H. S., Soong, C. Y., Yan, W. M., and Cheng, C. H., 2006, "An Analytical Solution for Transport of Oxygen in Cathode Gas Diffusion Layer of PEMFC", J. Power Sources, 160, pp. 50-56. (Pubitemid 44344370)
    • (2006) Journal of Power Sources , vol.160 , Issue.1 , pp. 50-56
    • Tsai, C.R.1    Chen, F.2    Ruo, A.C.3    Chang, M.-H.4    Chu, H.-S.5    Soong, C.Y.6    Yan, W.M.7    Cheng, C.H.8
  • 5
    • 33744984810 scopus 로고    scopus 로고
    • Gas-phase mass-transfer resistance at pemfc electrodes: Part 2. Effects of the flow geometry and the related pressure field
    • Arato, E., Pinna, M., and Costa, P., 2006, "Gas-Phase Mass-Transfer Resistance at PEMFC Electrodes: Part 2. Effects of the Flow Geometry and the Related Pressure Field", J. Power Sources, 158, pp. 206-212.
    • (2006) J. Power Sources , vol.158 , pp. 206-212
    • Arato, E.1    Pinna, M.2    Costa, P.3
  • 6
    • 0032136025 scopus 로고    scopus 로고
    • Impedance measurements of polymer electrolyte membrane fuel cells running on constant load
    • Diard, J. P., Gorrec, B. L., Montella, C., Poinsignon, C., and Vitter, G., 1998, "Impedance Measurements of Polymer Electrolyte Membrane Fuel Cells Running on Constant Load", J. Power Sources, 74, pp. 244-245.
    • (1998) J. Power Sources , vol.74 , pp. 244-245
    • Diard, J.P.1    Gorrec, B.L.2    Montella, C.3    Poinsignon, C.4    Vitter, G.5
  • 8
    • 33750946385 scopus 로고    scopus 로고
    • AC impedance diagnosis of a 500 W PEM fuel cell stack. Part I: Stack impedance
    • DOI 10.1016/j.jpowsour.2006.05.003, PII S0378775306008196
    • Yuan, X., Sun, J. C., Blanco, M., Wang, H., Zhang, J., and Wilkinson, D. P., 2006, "AC Impedance Diagnosis of a 500 W PEM Fuel Cell Stack: Part I: Stack Impedance", J. Power Sources, 161, pp. 920-928. (Pubitemid 44738749)
    • (2006) Journal of Power Sources , vol.161 , Issue.2 , pp. 920-928
    • Yuan, X.1    Sun, J.C.2    Blanco, M.3    Wang, H.4    Zhang, J.5    Wilkinson, D.P.6
  • 9
    • 0035917297 scopus 로고    scopus 로고
    • Effect of membrane characteristics and humidification conditions on the impedance response of polymer electrolyte fuel cells
    • Freire, T. J. P., and Gonzalez, E. R., 2001, "Effect of Membrane Characteristics and Humidification Conditions on the Impedance Response of Polymer Electrolyte Fuel Cells", J. Electroanal. Chem., 503, pp. 57-68.
    • (2001) J. Electroanal. Chem. , vol.503 , pp. 57-68
    • Freire, T.J.P.1    Gonzalez, E.R.2
  • 12
    • 34247348669 scopus 로고    scopus 로고
    • Pem stack test and analysis in a power system at operational load via ac impedance
    • Zhu, W. H., Payne, R. U., and Tatarchuk, B. J., 2007, "PEM Stack Test and Analysis in a Power System at Operational Load via ac Impedance", J. Power Sources, 168, pp. 211-217.
    • (2007) J. Power Sources , vol.168 , pp. 211-217
    • Zhu, W.H.1    Payne, R.U.2    Tatarchuk, B.J.3
  • 13
    • 0042411056 scopus 로고    scopus 로고
    • The effects of electropolishing (EP) process parameters on corrosion resistance of 316L stainless steel
    • Lee, S. J., and Lai, J. J., 2003, "The Effects of Electropolishing (EP) Process Parameters on Corrosion Resistance of 316L Stainless Steel", J. Mater. Process. Technol., 140, pp. 206-210.
    • (2003) J. Mater. Process. Technol. , vol.140 , pp. 206-210
    • Lee, S.J.1    Lai, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.