메뉴 건너뛰기




Volumn 34, Issue 8, 2010, Pages 677-684

Vascular cryografts offer better biomechanical properties in chronically hemodialyzed patients: Role of cryograft type, arterial pathway, and diabetic nephropathy as matching determinants: Thoughts and progress

Author keywords

Biomechanical mismatch; Diabetic nephropathy; Hemodialysis; Human vascular homografts; Pulse wave velocity

Indexed keywords

ACOUSTIC WAVE VELOCITY; BIOMECHANICS; PATHOLOGY; PROSTHETICS; STIFFNESS; WAVE PROPAGATION;

EID: 77955456102     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00962.x     Document Type: Article
Times cited : (5)

References (20)
  • 2
    • 0036526328 scopus 로고    scopus 로고
    • Hemodialysis vascular access dysfunction from basic biology to clinical intervention
    • Roy-Chaudhury P, Kelly BS, Narayana A, et al. Hemodialysis vascular access dysfunction from basic biology to clinical intervention. Adv Ren Replace Ther 2002 9 : 74 84.
    • (2002) Adv Ren Replace Ther , vol.9 , pp. 74-84
    • Roy-Chaudhury, P.1    Kelly, B.S.2    Narayana, A.3
  • 3
    • 0028808319 scopus 로고
    • Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts
    • Trubel W, Schima H, Moritz A, et al. Compliance mismatch and formation of distal anastomotic intimal hyperplasia in externally stiffened and lumen-adapted venous grafts. Eur J Vasc Endovasc Surg 1995 10 : 415 423.
    • (1995) Eur J Vasc Endovasc Surg , vol.10 , pp. 415-423
    • Trubel, W.1    Schima, H.2    Moritz, A.3
  • 4
    • 0346158211 scopus 로고    scopus 로고
    • Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: A review
    • Haruguchi H, Teraoka S. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review. J Artif Organs 2003 6 : 227 235.
    • (2003) J Artif Organs , vol.6 , pp. 227-235
    • Haruguchi, H.1    Teraoka, S.2
  • 5
    • 28444441964 scopus 로고    scopus 로고
    • Femoral arteries energy dissipation and filtering function remain unchanged after cryopreservation procedure
    • Bia D, Zócalo Y, Pessana F, et al. Femoral arteries energy dissipation and filtering function remain unchanged after cryopreservation procedure. Transpl Int 2005 18 : 1346 1355.
    • (2005) Transpl Int , vol.18 , pp. 1346-1355
    • Bia, D.1    Zócalo, Y.2    Pessana, F.3
  • 6
    • 33747888562 scopus 로고    scopus 로고
    • Cryopreservation procedure does not modify human carotid homografts mechanical properties: An isobaric and dynamic analysis
    • Bia D, Pessana F, Armentano R, et al. Cryopreservation procedure does not modify human carotid homografts mechanical properties: an isobaric and dynamic analysis. Cell Tissue Bank 2006 7 : 183 194.
    • (2006) Cell Tissue Bank , vol.7 , pp. 183-194
    • Bia, D.1    Pessana, F.2    Armentano, R.3
  • 7
    • 36248987802 scopus 로고    scopus 로고
    • Differential functional coupling between human saphenous cryoallografts and arteries: Importance of the arterial type and the biomechanical parameter evaluated
    • Bia D, Zócalo Y, Pessana F, et al. Differential functional coupling between human saphenous cryoallografts and arteries: importance of the arterial type and the biomechanical parameter evaluated. Artif Organs 2007 31 : 809 818.
    • (2007) Artif Organs , vol.31 , pp. 809-818
    • Bia, D.1    Zócalo, Y.2    Pessana, F.3
  • 8
    • 33847077245 scopus 로고    scopus 로고
    • Functional properties of fresh and cryopreserved carotid and femoral arteries, and of venous and synthetic grafts: Comparison with arteries from normotensive and hypertensive patients
    • Bia D, Armentano RL, Zócalo Y, et al. Functional properties of fresh and cryopreserved carotid and femoral arteries, and of venous and synthetic grafts: comparison with arteries from normotensive and hypertensive patients. Cell Tissue Bank 2007 8 : 43 57.
    • (2007) Cell Tissue Bank , vol.8 , pp. 43-57
    • Bia, D.1    Armentano, R.L.2    Zócalo, Y.3
  • 9
    • 3543024458 scopus 로고    scopus 로고
    • Experience with cryopreserved cadaveric femoral vein allografts used for hemodialysis access
    • Madden RL, Lipkowitz GS, Browne BJ, Kurbanov A. Experience with cryopreserved cadaveric femoral vein allografts used for hemodialysis access. Ann Vasc Surg 2004 18 : 453 458.
    • (2004) Ann Vasc Surg , vol.18 , pp. 453-458
    • Madden, R.L.1    Lipkowitz, G.S.2    Browne, B.J.3    Kurbanov, A.4
  • 10
    • 0036064792 scopus 로고    scopus 로고
    • Management of infected hemodialysis access grafts using cryopreserved human vein allografts
    • Lin PH, Brinkman WT, Terramani TT, Lumsden AB. Management of infected hemodialysis access grafts using cryopreserved human vein allografts. Am J Surg 2002 184 : 31 6.
    • (2002) Am J Surg , vol.184 , pp. 31-36
    • Lin, P.H.1    Brinkman, W.T.2    Terramani, T.T.3    Lumsden, A.B.4
  • 11
    • 0032214065 scopus 로고    scopus 로고
    • Cryopreserved femoral arterial allografts for vascular access in hemodialysis
    • Takamoto S, Nakajima S, Okita Y, et al. Cryopreserved femoral arterial allografts for vascular access in hemodialysis. Transpl Proc 1998 30 : 3917 3919.
    • (1998) Transpl Proc , vol.30 , pp. 3917-3919
    • Takamoto, S.1    Nakajima, S.2    Okita, Y.3
  • 12
    • 0030895089 scopus 로고    scopus 로고
    • Increased restenosis in diabetes mellitus after coronary interventions is due to exaggerated intimal hyperplasia. A serial intravascular ultrasound study
    • Kornowski R, Mintz GS, Kent KM, et al. Increased restenosis in diabetes mellitus after coronary interventions is due to exaggerated intimal hyperplasia. A serial intravascular ultrasound study. Circulation 1997 95 : 1366 1369.
    • (1997) Circulation , vol.95 , pp. 1366-1369
    • Kornowski, R.1    Mintz, G.S.2    Kent, K.M.3
  • 13
    • 0028242696 scopus 로고
    • Diabetes mellitus and experimental vein graft structure and function
    • Davies MG, Kim JH, Klyachkin ML, et al. Diabetes mellitus and experimental vein graft structure and function. J Vasc Surg 1994 19 : 1031 1043.
    • (1994) J Vasc Surg , vol.19 , pp. 1031-1043
    • Davies, M.G.1    Kim, J.H.2    Klyachkin, M.L.3
  • 14
    • 33750318148 scopus 로고    scopus 로고
    • European network for non-invasive investigation of large arteries. Expert consensus document on arterial stiffness: Methodological issues and clinical applications
    • Laurent S, Cockcroft J, Van Bortel L, et al. European network for non-invasive investigation of large arteries. Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur Heart J 2006 27 : 2588 2605.
    • (2006) Eur Heart J , vol.27 , pp. 2588-2605
    • Laurent, S.1    Cockcroft, J.2    Van Bortel, L.3
  • 16
    • 2142695404 scopus 로고    scopus 로고
    • The aging of elastic and muscular arteries: A comparison of diabetic and nondiabetic subjects
    • Cameron JD, Bulpitt CJ, Pinto ES, Rajkumar C. The aging of elastic and muscular arteries: a comparison of diabetic and nondiabetic subjects. Diabetes Care 2003 26 : 2133 2138.
    • (2003) Diabetes Care , vol.26 , pp. 2133-2138
    • Cameron, J.D.1    Bulpitt, C.J.2    Pinto, E.S.3    Rajkumar, C.4
  • 17
    • 0034768073 scopus 로고    scopus 로고
    • Diabetes mellitus and renal failure: Effects on large artery stiffness
    • Aoun S, Blacher J, Safar M, Mourad JJ. Diabetes mellitus and renal failure: effects on large artery stiffness. J Hum Hypertens 2001 15 : 693 700.
    • (2001) J Hum Hypertens , vol.15 , pp. 693-700
    • Aoun, S.1    Blacher, J.2    Safar, M.3    Mourad, J.J.4
  • 18
    • 0034827942 scopus 로고    scopus 로고
    • Diabetes mellitus, aortic stiffness, and cardiovascular mortality in end-stage renal disease
    • Shoji T, Emoto M, Shinohara K, et al. Diabetes mellitus, aortic stiffness, and cardiovascular mortality in end-stage renal disease. J Am Soc Nephrol 2001 12 : 2117 2124.
    • (2001) J Am Soc Nephrol , vol.12 , pp. 2117-2124
    • Shoji, T.1    Emoto, M.2    Shinohara, K.3
  • 19
    • 20544446891 scopus 로고    scopus 로고
    • Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia
    • Cabrera-Fischer EI, Bia D, Cassanello GL, et al. Reduced elastic mismatch achieved by interposing vein cuff in expanded polytetrafluoroethylene femoral bypass decreases intimal hyperplasia. Artif Organs 2005 29 : 122 130.
    • (2005) Artif Organs , vol.29 , pp. 122-130
    • Cabrera-Fischer, E.I.1    Bia, D.2    Cassanello, G.L.3
  • 20


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.