메뉴 건너뛰기




Volumn 7, Issue 2, 2010, Pages 0245021-0245024

Durability test results of a polymer electrolyte membrane fuel cell operated at overnominal temperature with low humidified reactants

Author keywords

Durability; Electrochemical impedance spectroscopy; Experimental; Low humidity conditions; PEMFC; Reliability

Indexed keywords

AGING MECHANISM; AGING TIME; DURABILITY TEST; ELECTROCHEMICAL IMPEDANCE SPECTRA; EXPERIMENTAL; GAS UTILIZATION; IMPEDANCE SPECTRUM; LONG-TERM EXPERIMENTS; LOW HUMIDITY CONDITIONS; NYQUIST PLOTS; OPERATING CONDITION; PERFLUORINATED IONOMER MEMBRANES; POLARIZATION CURVES; POLYMER ELECTROLYTE MEMBRANE FUEL CELLS; RESPONSE SURFACE; STATIC LOADS; VOLTAGE VARIATION;

EID: 77955438289     PISSN: 1550624X     EISSN: 15516989     Source Type: Journal    
DOI: 10.1115/1.3182736     Document Type: Article
Times cited : (3)

References (17)
  • 2
    • 34748828559 scopus 로고    scopus 로고
    • Thermal dynamic modeling and nonlinear control of a proton exchange membrane fuel cell stack
    • Kolodziej, J. R., 2007, "Thermal Dynamic Modeling and Nonlinear Control of a Proton Exchange Membrane Fuel Cell Stack", ASME J. Fuel Cell Sci. Technol., 4(3), pp. 255-260.
    • (2007) ASME J. Fuel Cell. Sci. Technol. , vol.4 , Issue.3 , pp. 255-260
    • Kolodziej, J.R.1
  • 3
    • 34748896557 scopus 로고    scopus 로고
    • Polimeric electrolyte membrane fuel cells: Characterization test under variable temperature and relative humidity conditions
    • Rinaldi, F., and Marchesi, R., 2007, "Polimeric Electrolyte Membrane Fuel Cells: Characterization Test Under Variable Temperature and Relative Humidity Conditions", ASME J. Fuel Cell Sci. Technol., 4(3), pp. 231-237.
    • (2007) ASME J. Fuel Cell. Sci. Technol. , vol.4 , Issue.3 , pp. 231-237
    • Rinaldi, F.1    Marchesi, R.2
  • 4
    • 33749037159 scopus 로고    scopus 로고
    • Analysis of single pem fuel cell performances based on current density distribution measurement
    • Ghosh, P. C., Wüster, T., Dohle, H., Kimiaie, N., Mergel, J., and Stolten, D., 2006, "Analysis of Single PEM Fuel Cell Performances Based on Current Density Distribution Measurement", ASME J. Fuel Cell Sci. Technol., 3(3), pp. 351-357.
    • (2006) ASME J. Fuel Cell. Sci. Technol. , vol.3 , Issue.3 , pp. 351-357
    • Ghosh, P.C.1    Wüster, T.2    Dohle, H.3    Kimiaie, N.4    Mergel, J.5    Stolten, D.6
  • 5
    • 34249871936 scopus 로고    scopus 로고
    • Mechanical behavior of fuel cell membranes under humidity cycles and effect of swelling anisotropy on the fatigue stresses
    • Kusoglu, A., Karlsson, A. M., Santare, M. H., Cleghorn, S., and Johnson, W. B., 2007, "Mechanical Behavior of Fuel Cell Membranes Under Humidity Cycles and Effect of Swelling Anisotropy on the Fatigue Stresses", J. Power Sources, 170(2), pp. 345-358.
    • (2007) J. Power Sources , vol.170 , Issue.2 , pp. 345-358
    • Kusoglu, A.1    Karlsson, A.M.2    Santare, M.H.3    Cleghorn, S.4    Johnson, W.B.5
  • 6
    • 77955297877 scopus 로고    scopus 로고
    • Viscoelastic stress analysis of constrained proton exchange membranes under humidity cycling
    • Lai, Y.-H., Mittelsteadt, C. K., Gittleman, C. S., and Dillard, D. A., 2009, "Viscoelastic Stress Analysis of Constrained Proton Exchange Membranes Under Humidity Cycling", ASME J. Fuel Cell Sci. Technol., 6, p. 021002.
    • (2009) ASME J. Fuel Cell. Sci. Technol. , vol.6 , pp. 021002
    • Lai, Y.-H.1    Mittelsteadt, C.K.2    Gittleman, C.S.3    Dillard, D.A.4
  • 8
    • 34248328770 scopus 로고    scopus 로고
    • Strain accumulation in polymer electrolyte membrane and membrane electrode assembly materials during a single hydration/dehydration cycle
    • Hector, L. G., Jr., Lai, Y.-H., Tong, W., and Lukitsch, M. J., 2007, "Strain Accumulation in Polymer Electrolyte Membrane and Membrane Electrode Assembly Materials During a Single Hydration/Dehydration Cycle", ASME J. Fuel Cell Sci. Technol., 4(1), pp. 19-28.
    • (2007) ASME J. Fuel Cell. Sci. Technol. , vol.4 , Issue.1 , pp. 19-28
    • Hector Jr., L.G.1    Lai, Y.-H.2    Tong, W.3    Lukitsch, M.J.4
  • 9
    • 36349028145 scopus 로고    scopus 로고
    • Combined measurement of PEMFC performance decay and water droplet distribution under low humidity and high CO
    • Murahashi, T., Kobayashi, H., and Nishiyama, E., 2008, "Combined Measurement of PEMFC Performance Decay and Water Droplet Distribution Under Low Humidity and High CO", J. Power Sources, 175(1), pp. 98-105.
    • (2008) J. Power Sources , vol.175 , Issue.1 , pp. 98-105
    • Murahashi, T.1    Kobayashi, H.2    Nishiyama, E.3
  • 11
    • 0031209161 scopus 로고    scopus 로고
    • Operating proton exchange membrane fuel cells without external humidification of the reactant gases
    • Büchi, F. N., and Srinivasan, S., 1997, "Operating Proton Exchange Membrane Fuel Cells Without External Humidification of the Reactant Gases", J. Electrochem. Soc, 144(8), pp. 2767-2772.
    • (1997) J. Electrochem. Soc. , vol.144 , Issue.8 , pp. 2767-2772
    • Büchi, F.N.1    Srinivasan, S.2
  • 12
    • 1542333432 scopus 로고    scopus 로고
    • Large-scale current fluctuations in PEM fuel cells operating with reduced feed stream humidification
    • Atkins, J. R., Savett, S. C., and Creager, S. E., 2004, "Large-Scale Current Fluctuations in PEM Fuel Cells Operating With Reduced Feed Stream Humidification", J. Power Sources, 128(2), pp. 201-207.
    • (2004) J. Power Sources , vol.128 , Issue.2 , pp. 201-207
    • Atkins, J.R.1    Savett, S.C.2    Creager, S.E.3
  • 13
    • 36549069667 scopus 로고    scopus 로고
    • Comparison between two PEM fuel cell durability tests performed at constant current and under solicitations linked to transport mission profile
    • Wahdame, B., Candusso, D., François, X., Harel, F., Péra, M.-C., Hissel, D., and Kauffmann, J.-M., 2007, "Comparison Between Two PEM Fuel Cell Durability Tests Performed at Constant Current and Under Solicitations Linked to Transport Mission Profile", Int. J. Hydrogen Energy, 32(17), pp. 4523-4536.
    • (2007) Int. J. Hydrogen Energy , vol.32 , Issue.17 , pp. 4523-4536
    • Wahdame, B.1    Candusso, D.2    François, X.3    Harel, F.4    Péra, M.-C.5    Hissel, D.6    Kauffmann, J.-M.7
  • 14
    • 36849056828 scopus 로고    scopus 로고
    • Characterisation of polymer electrolyte fuel cell for embedded generators. Test bench design and methodology
    • X.-W. Zhang, ed., Research Signpost, Kerala, India/North Carolina State University, Raleigh, NC
    • Hissel, D., Péra, M.-C., Candusso, D., Harel, F., and Bégot, S., 2005, "Characterisation of Polymer Electrolyte Fuel Cell for Embedded Generators. Test Bench Design and Methodology", Advances in Fuel Cells, X.-W. Zhang, ed., Research Signpost, Kerala, India/North Carolina State University, Raleigh, NC.
    • (2005) Advances in Fuel Cells
    • Hissel, D.1    Péra, M.-C.2    Candusso, D.3    Harel, F.4    Bégot, S.5
  • 15
    • 24944541532 scopus 로고    scopus 로고
    • New design of a PEM fuel cell air automatic climate control unit
    • Glises, R., Hissel, D., Harel, F., and Péra, M.-C., 2005, "New Design of a PEM Fuel Cell Air Automatic Climate Control Unit", J. Power Sources, 150, pp. 78-85.
    • (2005) J. Power Sources , vol.150 , pp. 78-85
    • Glises, R.1    Hissel, D.2    Harel, F.3    Péra, M.-C.4
  • 16
    • 33845646313 scopus 로고    scopus 로고
    • Flow rate and humidification effects on a PEM fuel cell performance and operation
    • Guvelioglu, G. H., and Stenger, H. G., 2007, "Flow Rate and Humidification Effects on a PEM Fuel Cell Performance and Operation", J. Power Sources, 163(2), pp. 882-891.
    • (2007) J. Power Sources , vol.163 , Issue.2 , pp. 882-891
    • Guvelioglu, G.H.1    Stenger, H.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.