-
1
-
-
0036151079
-
Cardiac transplantation
-
Deng MC. Cardiac transplantation. Heart 2002;87:177-184
-
(2002)
Heart
, vol.87
, pp. 177-184
-
-
Deng, M.C.1
-
2
-
-
10844244925
-
Drug therapy in the heart transplant recipient: Part I: Cardiac rejection and immunosuppressive drugs
-
Lindenfeld J, Miller GG, Shakar SF, Zolty R, Lowes BD,Wolfel EE. Drug therapy in the heart transplant recipient: part I: cardiac rejection and immunosuppressive drugs. Circulation 2004;110:3734-3740
-
(2004)
Circulation
, vol.110
, pp. 3734-3740
-
-
Lindenfeld, J.1
Miller, G.G.2
Shakar, S.F.3
Zolty, R.4
Lowes Bdwolfel, E.E.5
-
3
-
-
35548942656
-
The role of endomyocardial biopsy in the management of cardiovascular disease: A scientific statement from the American Heart Association, the American College of Cardiology, and the European Society of Cardiology Endorsed by the Heart Failure Society of America and the Heart Failure Association of the European Society of Cardiology
-
Cooper LT, Baughman KL, Feldman AM, Frustaci A, Jessup M, Kuhl U. The role of endomyocardial biopsy in the management of cardiovascular disease: a scientific statement from the American Heart Association, the American College of Cardiology, and the European Society of Cardiology Endorsed by the Heart Failure Society of America and the Heart Failure Association of the European Society of Cardiology. J Am Coll Cardiol 2007;50:1914-1931
-
(2007)
J Am Coll Cardiol
, vol.50
, pp. 1914-1931
-
-
Cooper, L.T.1
Baughman, K.L.2
Feldman, A.M.3
Frustaci, A.4
Jessup, M.5
Kuhl, U.6
-
4
-
-
0021908131
-
Clinical experience with two-dimensional echocardiography to guide endomyocardial biopsy
-
Williams GA, Kaintz RP, Habermehl KK, Nelson JG, Kennedy HL. Clinical experience with two-dimensional echocardiography to guide endomyocardial biopsy. Clin Cardiol 1985;8:137-140
-
(1985)
Clin Cardiol
, vol.8
, pp. 137-140
-
-
Williams, G.A.1
Kaintz, R.P.2
Habermehl, K.K.3
Nelson, J.G.4
Kennedy, H.L.5
-
5
-
-
27744506571
-
The efficacy of real-time 3-dimensional echocardiography for right ventricular biopsy
-
Monica A, Cinthia D, Layna D, Christopher D. The efficacy of real-time 3-dimensional echocardiography for right ventricular biopsy. J Am Soc Echocardiogr 2005;18:1208-1212
-
(2005)
J Am Soc Echocardiogr
, vol.18
, pp. 1208-1212
-
-
Monica, A.1
Cinthia, D.2
Layna, D.3
Christopher, D.4
-
6
-
-
0022364688
-
Two-dimensional echocardiographic monitoring during percutaneous endomyocardial biopsy
-
Strachovsky G, Zeldis SM, Katz S, McNulty-Mackey M, Strachovsky G, Zeldis SM. Two-dimensional echocardiographic monitoring during percutaneous endomyocardial biopsy. J Am Coll Cardiol 1985;6:609-611
-
(1985)
J Am Coll Cardiol
, vol.6
, pp. 609-611
-
-
Strachovsky, G.1
Zeldis, S.M.2
Katz, S.3
McNulty-Mackey, M.4
Strachovsky, G.5
Zeldis, S.M.6
-
7
-
-
0345164236
-
Echocardiography-guided endomyocardial biopsy. A 5-year experience
-
Miller LW, Labovitz AJ, McBride LA, Pennington DG, Kanter K. Echocardiography-guided endomyocardial biopsy. A 5-year experience. Circulation 1988;78:99-102.
-
(1988)
Circulation
, vol.78
, pp. 99-102
-
-
Miller, L.W.1
Labovitz, A.J.2
McBride, L.A.3
Pennington, D.G.4
Kanter, K.5
-
8
-
-
0026702039
-
Echo-controlled endomyocardial biopsy after orthotopic and heterotopic heart transplantation
-
Lamp B, Hamann P, Schwammenthal E, Weyand M, Breithardt G, Scheld HH. Echo-controlled endomyocardial biopsy after orthotopic and heterotopic heart transplantation. Transplant Proc 1992;24:2015.
-
(1992)
Transplant Proc
, vol.24
, pp. 2015
-
-
Lamp, B.1
Hamann, P.2
Schwammenthal, E.3
Weyand, M.4
Breithardt, G.5
Scheld, H.H.6
-
9
-
-
0027655799
-
Pediatric endomyocardial biopsy performed solely with echocardiographic guidance
-
Balzer D, Moorhead S, Saffitz JE, Sekarski DR, Canter CE. Pediatric endomyocardial biopsy performed solely with echocardiographic guidance. J Am Soc Echocardiogr 1993;6:510-515
-
(1993)
J Am Soc Echocardiogr
, vol.6
, pp. 510-515
-
-
Balzer, D.1
Moorhead, S.2
Saffitz, J.E.3
Sekarski, D.R.4
Canter, C.E.5
-
10
-
-
0035186021
-
DeFilippi CR. Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: A comparison with fluoroscopy
-
McCreery CJ, McCulloch M, Ahmad M, deFilippi CR. Real-time 3-dimensional echocardiography imaging for right ventricular endomyocardial biopsy: a comparison with fluoroscopy. J Am Soc Echocardiogr 2001;14:927-933
-
(2001)
J Am Soc Echocardiogr
, vol.14
, pp. 927-933
-
-
McCreery, C.J.1
McCulloch, M.2
Ahmad, M.3
-
11
-
-
12144280824
-
Echo-guided endomyocardial biopsy in heart transplant recipients
-
Bedanova H, Necas J, Petrikovits E, Pokorny P, Kovalova S, Malik P. Echo-guided endomyocardial biopsy in heart transplant recipients. Transpl Int 2004;17:622-625
-
(2004)
Transpl Int
, vol.17
, pp. 622-625
-
-
Bedanova, H.1
Necas, J.2
Petrikovits, E.3
Pokorny, P.4
Kovalova, S.5
Malik, P.6
-
12
-
-
33847616622
-
Comparison of three-dimensional echocardiography to two-dimensional echocardiography and fluoroscopy for monitoring of endomyocardial biopsy
-
Amitai ME, Schnittger I, Popp RL, Chow J, Brown P, Liang DH. Comparison of three-dimensional echocardiography to two-dimensional echocardiography and fluoroscopy for monitoring of endomyocardial biopsy. Am J Cardiol 2007;99: 864-866
-
(2007)
Am J Cardiol
, vol.99
, pp. 864-866
-
-
Amitai, M.E.1
Schnittger, I.2
Popp, R.L.3
Chow, J.4
Brown, P.5
Liang, D.H.6
-
13
-
-
0026592734
-
Complications of transvenous right ventricular endomyocardial biopsy in adult patients with cardiomyopathy: A seven-year survey of 546 consecutive diagnostic procedures in a tertiary referral center
-
Deckers JW, Hare JM, Baughman KL. Complications of transvenous right ventricular endomyocardial biopsy in adult patients with cardiomyopathy: a seven-year survey of 546 consecutive diagnostic procedures in a tertiary referral center. J Am Coll Cardiol 1992;19:43-47
-
(1992)
J Am Coll Cardiol
, vol.19
, pp. 43-47
-
-
Deckers, J.W.1
Hare, J.M.2
Baughman, K.L.3
-
16
-
-
0027521040
-
Superior accuracy of anatomic positioning with echocardiographic-over fluoroscopicguided endomyocardial biopsy
-
Calvin AB, Morton JK, Frank VA, Thomas D, Richard B, Thomas W. Superior accuracy of anatomic positioning with echocardiographic-over fluoroscopicguided endomyocardial biopsy. Catheter Cardiovasc Diagn 1993;28:291-294
-
(1993)
Catheter Cardiovasc Diagn
, vol.28
, pp. 291-294
-
-
Calvin, A.B.1
Morton, J.K.2
Frank, V.A.3
Thomas, D.4
Richard, B.5
Thomas, W.6
-
17
-
-
0026581510
-
Realtime monitoring of the endomyocardial biopsy site with pediatric transesophageal echocardiography
-
Kawauchi M, Gundry SR, Boucek MM, de Begona JA, Vigesaa R, Bailey LL. Realtime monitoring of the endomyocardial biopsy site with pediatric transesophageal echocardiography. J Heart Lung Transplant 1992;11:306-310
-
(1992)
J Heart Lung Transplant
, vol.11
, pp. 306-310
-
-
Kawauchi, M.1
Gundry, S.R.2
Boucek, M.M.3
De Begona, J.A.4
Vigesaa, R.5
Bailey, L.L.6
-
18
-
-
0021908131
-
Clinical experience with two-dimensional echocardiography to guide endomyocardial biopsy
-
Williams GA, Kaintz RP, Habermehl KK, Nelson JG, Kennedy HL. Clinical experience with two-dimensional echocardiography to guide endomyocardial biopsy. Clin Cardiol 1985;8:137-140
-
(1985)
Clin Cardiol
, vol.8
, pp. 137-140
-
-
Williams, G.A.1
Kaintz, R.P.2
Habermehl, K.K.3
Nelson, J.G.4
Kennedy, H.L.5
-
19
-
-
0021280415
-
Two-dimensional echocardiographic guiding of endomyocardial biopsy
-
Pierard L, El Allaf D, DOrio V, Demoulin JC, Carlier J. Two-dimensional echocardiographic guiding of endomyocardial biopsy. Chest 1984;85:759-762
-
(1984)
Chest
, vol.85
, pp. 759-762
-
-
Pierard, L.1
El Allaf, D.2
Dorio, V.3
Demoulin, J.C.4
Carlier, J.5
-
20
-
-
0025123353
-
Echo-controlled endomyocardial biopsy
-
Ragni T, Martinelli L, Goggi C, Speziali G, Rinaldi M, Roda G. Echo-controlled endomyocardial biopsy. J Heart Lung Transplant 1990;9:538-542
-
(1990)
J Heart Lung Transplant
, vol.9
, pp. 538-542
-
-
Ragni, T.1
Martinelli, L.2
Goggi, C.3
Speziali, G.4
Rinaldi, M.5
Roda, G.6
-
21
-
-
0026261674
-
Surveillance for rejection by echocardiographically guided endomyocardial biopsy in the infant heart transplant recipient
-
Canter CE, Appleton RS, Saffitz JE, Bologna S, Miller L, Pennington DG. Surveillance for rejection by echocardiographically guided endomyocardial biopsy in the infant heart transplant recipient. Circulation 1991;84:310-315
-
(1991)
Circulation
, vol.84
, pp. 310-315
-
-
Canter, C.E.1
Appleton, R.S.2
Saffitz, J.E.3
Bologna, S.4
Miller, L.5
Pennington, D.G.6
-
22
-
-
0027166867
-
Safety of transvenous right ventricular endomyocardial biopsy guided by two-dimensional echocardiography
-
Blomstrom-Lundqvist C, Noor AM, Eskilsson J, Persson S. Safety of transvenous right ventricular endomyocardial biopsy guided by two-dimensional echocardiography. Clin Cardiol 1993;16:487-492
-
(1993)
Clin Cardiol
, vol.16
, pp. 487-492
-
-
Blomstrom-Lundqvist, C.1
Noor, A.M.2
Eskilsson, J.3
Persson, S.4
-
23
-
-
0031747298
-
Echo-guided endomyocardial biopsy in heterotopic heart transplantation. Case report
-
Grande AM, De Pieri G, Pederzolli C, Rinaldi M, Vigano M. Echo-guided endomyocardial biopsy in heterotopic heart transplantation. Case report. J Cardiovasc Surg 1998;39:223-225
-
(1998)
J Cardiovasc Surg
, vol.39
, pp. 223-225
-
-
Grande, A.M.1
De Pieri, G.2
Pederzolli, C.3
Rinaldi, M.4
Vigano, M.5
-
24
-
-
50249182904
-
Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer
-
Hyun Suk Y, Ramesh CB, Farouk M, Bijoy KK, Tajik AJ, Krishnaswamy C. Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer. J Am Soc Echocardiogr 2008;21:979-989
-
(2008)
J Am Soc Echocardiogr
, vol.21
, pp. 979-989
-
-
Hyun Suk, Y.1
Ramesh, C.B.2
Farouk, M.3
Bijoy, K.K.4
Tajik, A.J.5
Krishnaswamy, C.6
-
25
-
-
33645068884
-
Early experience with real-time three-dimensional echocardiographic guidance of right ventricular biopsy in children
-
Scheurer M, Bandisode V, Ruff P, Atz A, Shirali G. Early experience with real-time three-dimensional echocardiographic guidance of right ventricular biopsy in children. Echocardiography 2006;23:45-49
-
(2006)
Echocardiography
, vol.23
, pp. 45-49
-
-
Scheurer, M.1
Bandisode, V.2
Ruff, P.3
Atz, A.4
Shirali, G.5
-
26
-
-
0027521040
-
Superior accuracy of anatomic positioning with echocardiographic-over fluoroscopic-guided endomyocardial biopsy
-
Bell CA, Kern MJ, Aguirre FV, Donohue T, Bach R, Wolford T. Superior accuracy of anatomic positioning with echocardiographic-over fluoroscopic-guided endomyocardial biopsy. Catheter Cardiovasc Diagn 1993;28:291-294
-
(1993)
Catheter Cardiovasc Diagn
, vol.28
, pp. 291-294
-
-
Bell, C.A.1
Kern, M.J.2
Aguirre, F.V.3
Donohue, T.4
Bach, R.5
Wolford, T.6
-
27
-
-
17144457263
-
Tricuspid valve insufficiency as a complication of endomyocardial biopsy
-
Wiklund L, Caidahl K, Kjellstrom C, Nilsson B, Svensson G, Berglin E. Tricuspid valve insufficiency as a complication of endomyocardial biopsy. Transpl Int 1992; 5:S255-8.
-
(1992)
Transpl Int
, vol.5
-
-
Wiklund, L.1
Caidahl, K.2
Kjellstrom, C.3
Nilsson, B.4
Svensson, G.5
Berglin, E.6
-
28
-
-
0027571001
-
Tricuspid flail leaflets after orthotopic heart transplant: A new complication of endomyocardial biopsy
-
Reddy SC, Rath GA, Ziady GM, Matesic C, Kormos R. Tricuspid flail leaflets after orthotopic heart transplant: a new complication of endomyocardial biopsy. J Am Soc Echocardiogr 1993;6:223-226
-
(1993)
J Am Soc Echocardiogr
, vol.6
, pp. 223-226
-
-
Reddy, S.C.1
Rath, G.A.2
Ziady, G.M.3
Matesic, C.4
Kormos, R.5
|