메뉴 건너뛰기




Volumn 48, Issue 10, 2010, Pages 974-977

Laser distance measurement using a newly developed composite-type optical fiberscope for fetoscopic laser surgery

Author keywords

Composite type optical fiberscope (COF); Distance measurement; Endoscopic surgery; Fetal surgery; Laser blood flow meter

Indexed keywords

AMNIOTIC FLUID; COMMUNICATING VESSELS; ENDOSCOPIC SURGERY; EXPERIMENTAL ENVIRONMENT; FETAL SURGERY; IN-VIVO; IN-VIVO EXPERIMENTS; LASER IRRADIATIONS; LASER LIGHTS; MORTALITY RATE; NEW SYSTEM; TARGET OBJECT; TARGET VESSELS;

EID: 77955430670     PISSN: 01438166     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.optlaseng.2010.05.010     Document Type: Article
Times cited : (8)

References (17)
  • 2
    • 0034521928 scopus 로고    scopus 로고
    • Selective versus non-selective laser photocoagulation of placental vessels in twin-to-twin transfusion syndrome
    • R.A. Quintero, C. Comas, P.W. Bornick, M.H. Allen, and M. Kruger Selective versus non-selective laser photocoagulation of placental vessels in twin-to-twin transfusion syndrome Ultrasound Obstet Gynecol 16 2000 230 236
    • (2000) Ultrasound Obstet Gynecol , vol.16 , pp. 230-236
    • Quintero, R.A.1    Comas, C.2    Bornick, P.W.3    Allen, M.H.4    Kruger, M.5
  • 4
    • 0035127072 scopus 로고    scopus 로고
    • Selective laser photocoagulation of communicating vessels in severe twintwin transfusion syndrome in women with an anterior placenta
    • R.A. Quintero, P.W. Bornick, M.H. Allen, and P.K. Johnson Selective laser photocoagulation of communicating vessels in severe twintwin transfusion syndrome in women with an anterior placenta Obstet Gynecol 97 2001 477 481
    • (2001) Obstet Gynecol , vol.97 , pp. 477-481
    • Quintero, R.A.1    Bornick, P.W.2    Allen, M.H.3    Johnson, P.K.4
  • 5
    • 3042728865 scopus 로고    scopus 로고
    • Endoscopic laser surgery versus serial amnioreduction for severe twin-to-twin transfusion syndrome
    • M.V. Senat, J. Deprest, M. Boulvain, A. Paupe, N. Winer, and Y. Ville Endoscopic laser surgery versus serial amnioreduction for severe twin-to-twin transfusion syndrome N Engl J Med 351 2004 136 144
    • (2004) N Engl J Med , vol.351 , pp. 136-144
    • Senat, M.V.1    Deprest, J.2    Boulvain, M.3    Paupe, A.4    Winer, N.5    Ville, Y.6
  • 7
    • 0035164488 scopus 로고    scopus 로고
    • A new method to perform quantitative measurement of bronchoscopic images
    • P.K. McFawn, L. Forkert, and J.T. Fisher A new method to perform quantitative measurement of bronchoscopic images Eur Respir J 8 2001 817 826
    • (2001) Eur Respir J , vol.8 , pp. 817-826
    • McFawn, P.K.1    Forkert, L.2    Fisher, J.T.3
  • 9
    • 77955418574 scopus 로고    scopus 로고
    • Electronic endoscope system for 3-D shape measurement
    • K. Hasegawa, K. Noda, and T. Sato Electronic endoscope system for 3-D shape measurement Inst Electron Inf Commun Eng 2001 1222 1230 J84-D
    • (2001) Inst Electron Inf Commun Eng , pp. 1222-1230
    • Hasegawa, K.1    Noda, K.2    Sato, T.3
  • 12
    • 77949377375 scopus 로고    scopus 로고
    • Distance measuring navigation for fetoscopic laser photocoagulation to treat twin-to-twin transfusion syndrome: Feasibility evaluations
    • H. Yamashita, T. Yamashita, K. Masamune, H. Liao, K. Kim, and T. Chiba Distance measuring navigation for fetoscopic laser photocoagulation to treat twin-to-twin transfusion syndrome: feasibility evaluations IFMBE Proc 25 2009 197 200
    • (2009) IFMBE Proc , vol.25 , pp. 197-200
    • Yamashita, H.1    Yamashita, T.2    Masamune, K.3    Liao, H.4    Kim, K.5    Chiba, T.6
  • 13
    • 50249120755 scopus 로고    scopus 로고
    • A new optical fiber system with hybrid functions of power delivery and real-time remote observation for YAG laser welding
    • K. Oka A new optical fiber system with hybrid functions of power delivery and real-time remote observation for YAG laser welding Rev Laser Eng 31 2003 612 617
    • (2003) Rev Laser Eng , vol.31 , pp. 612-617
    • Oka, K.1
  • 14
    • 77950281413 scopus 로고    scopus 로고
    • The development of composite-type optical fiberscope system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels (FLPC)
    • Oka K, Seki T, Naganawa A, Yamashita H, Kim K, Chiba T. The development of composite-type optical fiberscope system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels (FLPC). Minim Invasiv Ther 2010;19(2):949
    • (2010) Minim Invasiv Ther , vol.19 , Issue.2 , pp. 94-99
    • Oka, K.1    Seki, T.2    Naganawa, A.3    Yamashita, H.4    Kim, K.5    Chiba, T.6
  • 15
    • 73349108114 scopus 로고    scopus 로고
    • Blood flow measurement system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels
    • T. Seki, K. Oka, A. Naganawa, H. Yamashita, K. Kim, and T. Chiba Blood flow measurement system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels Minim Invasiv Ther 18 2009 350 355
    • (2009) Minim Invasiv Ther , vol.18 , pp. 350-355
    • Seki, T.1    Oka, K.2    Naganawa, A.3    Yamashita, H.4    Kim, K.5    Chiba, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.