메뉴 건너뛰기




Volumn 9, Issue 9, 2009, Pages 1076-1083

Velocity profile measurement using digital signal processor-based optical tomography system

Author keywords

Digital signal processor (DSP); Optical tomography; Velocity measurement

Indexed keywords

ACQUISITION PROCESS; CROSS CORRELATIONS; DATA ACQUISITION SYSTEM; DIGITAL SIGNALS; DSP SYSTEM; EXTERNAL SIGNALS; PARALLEL BEAMS; PROCESS TOMOGRAPHY; PROCESSING TOOLS; SILICON FABRICATION TECHNOLOGIES; VELOCITY PROFILES;

EID: 77955414085     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2009.2025853     Document Type: Article
Times cited : (10)

References (18)
  • 3
    • 80053332851 scopus 로고    scopus 로고
    • Infrared tomography: Data distribution system for real-time mass flow rate measurement
    • A. R. Rahim, JF Pang, KS Chan, LC Leong, and MH F. Rahiman, "Infrared tomography: Data distribution system for real-time mass flow rate measurement," Sens. Transducers J., vol. 80, no. 6, pp. 1277-1288, 2007.
    • (2007) Sens. Transducers J. , vol.80 , Issue.6 , pp. 1277-1288
    • Rahim, A.R.1    Pang, J.F.2    Chan, K.S.3    Leong, L.C.4    Rahiman, M.H.F.5
  • 5
    • 0023378626 scopus 로고
    • Non-intrusive measurement of solids mass flow in pneumatic conveying
    • M. S. Beck, R. G. Green, and R. Thorn, "Non-intrusive measurement of solids mass flow in pneumatic conveying," J. Phys. E: Sci. Instrum., vol. 20, no. 7, pp. 835-840, Jul. 1987. (Pubitemid 17621621)
    • (1987) Journal of Physics E: Scientific Instruments , vol.20 , Issue.7 , pp. 835-840
    • Beck, M.S.1    Green, R.G.2    Thorn, R.3
  • 6
    • 0024732310 scopus 로고
    • Mass-flow measurement of solids using electrodynamic and capacitance transducers
    • Sep
    • C. G. Xie, A. L. Stott, S. M. Huang, A. Plaskowski, and M. S. Beck, "Mass-flow measurement of solids using electrodynamic and capacitance transducers," J. Phys. E: Sci. Instrum., vol. 22, no. 9, pp. 712-719, Sep. 1989.
    • (1989) J. Phys. E: Sci. Instrum. , vol.22 , Issue.9 , pp. 712-719
    • Xie, C.G.1    Stott, A.L.2    Huang, S.M.3    Plaskowski, A.4    Beck, M.S.5
  • 9
    • 43049113465 scopus 로고    scopus 로고
    • Velocity measurement using optical sensors. Semiconductor electronics, 2002
    • Dec. 19-21
    • S. Ibrahim and R. G. Green, "Velocity measurement using optical sensors. Semiconductor electronics, 2002," in Proc. IEEE ICSE Int. Conf., Dec. 19-21, 2002, pp. 126-129.
    • (2002) Proc. IEEE ICSE Int. Conf. , pp. 126-129
    • Ibrahim, S.1    Green, R.G.2
  • 10
    • 43049129940 scopus 로고    scopus 로고
    • Real time image reconstruction system using two data processing unit in optical tomography
    • Lodz, Poland Sep. 9-10
    • J. F. Pang, R. A. Rahim, and C. K. Chan, "Real time image reconstruction system using two data processing unit in optical tomography," in Proc. 3rd Int. Symp. Process Tomography, Lodz, Poland, Sep. 9-10, 2004, pp. 56-59.
    • (2004) Proc. 3rd Int. Symp. Process Tomography , pp. 56-59
    • Pang, J.F.1    Rahim, R.A.2    Chan, C.K.3
  • 11
    • 0030434764 scopus 로고    scopus 로고
    • Mass flow measurement of bulk solids in pneumatic pipelines
    • Y. Yan, "Mass flow measurement of bulk solids in pneumatic pipelines," Meas. Sci. Technol., vol. 7, no. 12, pp. 1687-1706, Dec. 1996. (Pubitemid 126531544)
    • (1996) Measurement Science and Technology , vol.7 , Issue.12 , pp. 1687-1706
    • Yan, Y.1
  • 12
    • 0020209109 scopus 로고
    • Non-intrusive methods of velocity measurement in pneumatic conveying
    • R. Thorn, M. S. Beck, and R. G. Green, "Non-intrusive methods of velocity measurement in pneumatic conveying," J. Phys. E: Sci. Instrum., vol. 15, pp. 1131-1139, 1982.
    • (1982) J. Phys. E: Sci. Instrum. , vol.15 , pp. 1131-1139
    • Thorn, R.1    Beck, M.S.2    Green, R.G.3
  • 13
    • 0025432134 scopus 로고
    • Flow velocity profile via time-domain correlation: Error analysis and computer simulation ultrasonics, ferroelectrics and frequency control
    • May
    • S. G. Foster, P. M. Embree, O'Brien, and W. D. Jr., "Flow velocity profile via time-domain correlation: Error analysis and computer simulation ultrasonics, ferroelectrics and frequency control," IEEE Trans., vol. 37, no. 3, pp. 164-175, May 1990.
    • (1990) IEEE Trans. , vol.37 , Issue.3 , pp. 164-175
    • Foster, S.G.1    Embree O'brien, P.M.2    Jr., W.D.3
  • 15
    • 33845622885 scopus 로고    scopus 로고
    • Ultrasonic transmission-mode tomography imaging for liquid/gas two-phase flow
    • MF R. Rahiman and A. R. Rahim, "Ultrasonic transmission-mode tomography imaging for liquid/gas two-phase flow," IEEE Sensors J., vol. 6, pp. 1706-1715, 2006.
    • (2006) IEEE Sensors J. , vol.6 , pp. 1706-1715
    • Rahiman, M.F.R.1    Rahim, A.R.2
  • 17
    • 58449128150 scopus 로고    scopus 로고
    • Optical tomography: Real-time velocity profile measurement using pixel-to-pixel & sensor-to-sensor method
    • A. R. Rahim, JF Pang, and KS Chan, "Optical tomography: Real-time velocity profile measurement using pixel-to-pixel & sensor-to-sensor method," J. Opt. Eng., vol. 45, no. 3, pp. 77-81, 2006.
    • (2006) J. Opt. Eng. , vol.45 , Issue.3 , pp. 77-81
    • Rahim, A.R.1    Pang, J.F.2    Chan, K.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.