메뉴 건너뛰기




Volumn 22, Issue 4, 2010, Pages 301-306

A low-noise low-power front-end amplifier for neural-recording applications

Author keywords

Biosignal amplifier; Neural recording; Operational transconductance amplifier; Subthreshold circuit design

Indexed keywords

BIO-SIGNAL AMPLIFIER; BIOLOGICAL SIGNALS; BRAIN-COMPUTER INTERFACE; CENTRAL NERVOUS SYSTEMS; CMOS PROCESSS; DESIRED SIGNAL; DIRECT CURRENT; ELECTRICAL ACTIVITIES; FRONT END; FRONT-END AMPLIFIER; FULLY DIFFERENTIAL; HEAT DISSIPATION; IN-VIVO; LOW NOISE; LOW POWER; MIXED MODE; NATURAL FUNCTIONS; NEURAL RECORDINGS; NOISE LEVELS; OPERATIONAL TRANS CONDUCTANCE AMPLIFIER; OUTPUT SWING; PARALLEL CHANNEL; POWER CONSUMPTION; PRACTICAL SOLUTIONS; RFIC DESIGN; SUBTHRESHOLD CIRCUITS; SYSTEM-ON-A-CHIP; TISSUE DAMAGE; TOTAL HARMONIC DISTORTIONS; ULTRA-LOW POWER; WIDE-BAND;

EID: 77955339679     PISSN: 10162372     EISSN: None     Source Type: Journal    
DOI: 10.4015/S1016237210002067     Document Type: Article
Times cited : (2)

References (23)
  • 1
    • 0032888084 scopus 로고    scopus 로고
    • A 100-channel system for real time detection and storage of extracellular spike waveforms
    • Guillory K, Normann RA, A 100-channel system for real time detection and storage of extracellular spike waveforms, J Neurosci Meth 91:21-29, 1999.
    • (1999) J Neurosci Meth , vol.91 , pp. 21-29
    • Guillory, K.1    Normann, R.A.2
  • 3
    • 77953849748 scopus 로고    scopus 로고
    • Effects of the microelectrodes geometry on action potential recording capabilities: A 3D FEM simulation study
    • Moulin1 C, Gliere A, Barbier D, et al., Effects of the microelectrodes geometry on action potential recording capabilities: A 3D FEM simulation study, 20th European Conference on Solid-State Transducers, 2006.
    • (2006) 20th European Conference on Solid-State Transducers
    • Moulinl, C.1    Gliere, A.2    Barbier, D.3
  • 6
    • 21844471300 scopus 로고    scopus 로고
    • Band tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays
    • Olsson RH III, Gulari MN, Wise KD, Band tunable and multiplexed integrated circuits for simultaneous recording and stimulation with microelectrode arrays, IEEE Trans Biomed Eng 52(7):1302-1311, 2005.
    • (2005) IEEE Trans Biomed Eng , vol.52 , Issue.7 , pp. 1302-1311
    • Olsson Iii, R.H.1    Gulari, M.N.2    Wise, K.D.3
  • 8
    • 1942542472 scopus 로고    scopus 로고
    • A fully integrated neural recording amplifier with DC input stabilization
    • Mosheni P, Najafi K, A fully integrated neural recording amplifier with DC input stabilization, IEEE Trans Biomed Eng 51:832-837, 2004.
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 832-837
    • Mosheni, P.1    Najafi, K.2
  • 9
    • 0035013786 scopus 로고    scopus 로고
    • A micropower low-noise log-domain amplifier for the sensing chain of a cardiac pacemaker
    • Gerosa A, Novo A, Mengalli A, et al., A micropower low-noise log-domain amplifier for the sensing chain of a cardiac pacemaker, Int Symp Circuits Syst 1:296-299, 2001.
    • (2001) Int Symp Circuits Syst , vol.1 , pp. 296-299
    • Gerosa, A.1    Novo, A.2    Mengalli, A.3
  • 11
    • 0026735250 scopus 로고
    • A glass/silicon composite intracortical electrode array
    • Jones KE, Campbell PK, Normann RA, A glass/silicon composite intracortical electrode array, Ann Biomed Eng 20:423-437, 1992.
    • (1992) Ann Biomed Eng , vol.20 , pp. 423-437
    • Jones, K.E.1    Campbell, P.K.2    Normann, R.A.3
  • 13
    • 84937994376 scopus 로고
    • The electrical properties of metal micro- electrodes
    • Robinson DA, The electrical properties of metal micro- electrodes, Proc IEEE 56:1065-1071, 1968.
    • (1968) Proc IEEE , vol.56 , pp. 1065-1071
    • Robinson, D.A.1
  • 14
    • 1942478627 scopus 로고    scopus 로고
    • Cultured neurons coupled to microelectrode arrays: Circuit models, simulations and experimental data
    • Martinoia S, Massobrio P, Bove M, et al., Cultured neurons coupled to microelectrode arrays: Circuit models, simulations and experimental data, IEEE Trans Biomed Eng 51:859-864, 2004.
    • (2004) IEEE Trans Biomed Eng , vol.51 , pp. 859-864
    • Martinoia, S.1    Massobrio, P.2    Bove, M.3
  • 15
    • 37049137333 scopus 로고
    • Site-binding model of the electrical double layer at the oxide/water interface
    • Yates DE, Levine S, Healy TW, Site-binding model of the electrical double layer at the oxide/water interface, J Chem Soc Faraday Trans 70:1807-1818, 1974.
    • (1974) J Chem Soc Faraday Trans , vol.70 , pp. 1807-1818
    • Yates, D.E.1    Levine, S.2    Healy, T.W.3
  • 17
    • 34247857458 scopus 로고    scopus 로고
    • Brain- silicon interface for high-resolution in vitro neural recording
    • Aziz JNY, Genov R, Bardakjian BL, et al., Brain- silicon interface for high-resolution in vitro neural recording, IEEE Trans Biomed Circuit Syst 1(1):2007.
    • (2007) IEEE Trans Biomed Circuit Syst , vol.1 , Issue.1
    • Jny, A.1    Genov, R.2    Bardakjian, B.L.3
  • 19
    • 49549100041 scopus 로고    scopus 로고
    • A 128-channel 6mW wireless neural recording IC with On-the-Fly spike sorting and UWB transmitter
    • Chae M, Liu W, Yang Z, et al., A 128-channel 6mW wireless neural recording IC with On-the-Fly spike sorting and UWB transmitter, IEEE International Solid- State Circuits Conference, 2008.
    • (2008) IEEE International Solid- State Circuits Conference
    • Chae, M.1    Liu, W.2    Yang, Z.3
  • 20
    • 0032424528 scopus 로고    scopus 로고
    • Characterization of tissue morphology, angiogenesis, and temperature in the adaptive response of muscle tissue to chronic heating
    • Seese TM, Harasaki H, Saidel GM, et al., Characterization of tissue morphology, angiogenesis, and temperature in the adaptive response of muscle tissue to chronic heating, Lab Invest 78(12):1553-1562, 1998.
    • (1998) Lab Invest , vol.78 , Issue.12 , pp. 1553-1562
    • Seese, T.M.1    Harasaki, H.2    Saidel, G.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.