메뉴 건너뛰기




Volumn 182, Issue 8, 2010, Pages 706-714

Is ultrasound equal to X-ray in pediatric fracture diagnosis?;Ist die Sonografie der Röntgendiagnostik in der pädiatrischen Frakturdiagnostik gleichwertig?

Author keywords

children, injuries; experimental study; infants, injuries; radiography; skeletal appendicular; ultrasound

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DISLOCATION; ECHOGRAPHY; FRACTURE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SWINE; X RAY;

EID: 77955256775     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-0029-1245371     Document Type: Article
Times cited : (20)

References (32)
  • 1
    • 47249098508 scopus 로고    scopus 로고
    • Zur Strahlenexposition von Kindern in der pädiatrischen Radiologie. Teil 1: Indikationen und Röntgenuntersuchungshäufigkeiten in der konventionellen radiologischen Diagnostik an einer Universitäts- Kinderklinik zwischen 1976 und 2003
    • Seidenbusch M C., Schneider K. Zur Strahlenexposition von Kindern in der pädiatrischen Radiologie. Teil 1: Indikationen und Rö ntgenuntersuchungshäufigkeiten in der konventionellen radiologischen Diagnostik an einer Universitäts-Kinderklinik zwischen 1976 und 2003. Fortschr Röntgenstr 2008 180 410-422
    • (2008) Fortschr Röntgenstr , vol.180 , pp. 410-422
    • Seidenbusch, M.C.1    Schneider, K.2
  • 2
    • 47249091800 scopus 로고    scopus 로고
    • Zur Strahlenexposition von Kindern in der pädiatrischen Radiologie. Teil 2: Der PÄDOS-Algorithmus zur rechnergestützten Dosisrekonstruktion in der Kinderradiologie am Beispiel der Rö ntgenuntersuchung des Schädels
    • Seidenbusch M C., Regulla D, Schneider K. Zur Strahlenexposition von Kindern in der pädiatrischen Radiologie. Teil 2: Der PÄDOS-Algorithmus zur rechnergestützten Dosisrekonstruktion in der Kinderradiologie am Beispiel der Röntgenuntersuchung des Schädels. Fortschr Röntgenstr 2008 180 522-539
    • (2008) Fortschr Röntgenstr , vol.180 , pp. 522-539
    • Seidenbusch, M.C.1    Regulla, D.2    Schneider, K.3
  • 3
    • 57649136651 scopus 로고    scopus 로고
    • Zur Strahlenexposition von Kindern in der pädiatrischen Radiologie. Teil 4: Einfalldosen bei der Röntgenuntersuchung des Thorax
    • Seidenbusch M C., Schneider K. Zur Strahlenexposition von Kindern in der pädiatrischen Radiologie. Teil 4: Einfalldosen bei der Rö ntgenuntersuchung des Thorax. Fortschr Röntgenstr 2008 180 1082-1103
    • (2008) Fortschr Röntgenstr , vol.180 , pp. 1082-1103
    • Seidenbusch, M.C.1    Schneider, K.2
  • 4
    • 47249117538 scopus 로고    scopus 로고
    • Phantomuntersuchung zur Strahlenreduktion mittels neuerer, auf Nadelstruktur basierender Speicherfolienradiografie und Zusatzfilterung in der Thoraxradiographie bei Jugendlichen und größeren Kindern
    • Heyme J P., Mentzel H J., Neumann R et al. Phantomuntersuchung zur Strahlenreduktion mittels neuerer, auf Nadelstruktur basierender Speicherfolienradiografie und Zusatzfilterung in der Thoraxradiographie bei Jugendlichen und größeren Kindern. Fortschr Röntgenstr 2008 180 231-237
    • (2008) Fortschr Röntgenstr , vol.180 , pp. 231-237
    • Heyme, J.P.1    Mentzel, H.J.2    Neumann, R.3
  • 5
    • 33745164246 scopus 로고    scopus 로고
    • Occult scaphoid fractures: Comparison of multidetector CT and MR imaging Initial Experience
    • Memarsadeghi M, Breitenseher M J., Schaefer-Prokop C et al. Occult scaphoid fractures: Comparison of multidetector CT and MR imaging Initial Experience. Radiology 2006 240 169-176
    • (2006) Radiology , vol.240 , pp. 169-176
    • Memarsadeghi, M.1    Breitenseher, M.J.2    Schaefer-Prokop, C.3
  • 6
    • 0029449006 scopus 로고
    • Einsatzmöglichkeiten der Sonographie als diagnostisches Verfahren bei Frakturen im Wachstumsalter
    • Rathfelder F J., Paar O. Einsatzmöglichkeiten der Sonographie als diagnostisches Verfahren bei Frakturen im Wachstumsalter. Unfallchirurg 1995 98 645-649
    • (1995) Unfallchirurg , vol.98 , pp. 645-649
    • Rathfelder, F.J.1    Paar, O.2
  • 7
    • 0033127525 scopus 로고    scopus 로고
    • Ultrasonographic diagnosis of an epiphyseal detachment of the upper end of the humerus due to birth injury
    • Schmit P, Hautefort P, Raison-Boulley A M. Ultrasonographic diagnosis of an epiphyseal detachment of the upper end of the humerus due to birth injury. J Radiol 1999 80 466-468
    • (1999) J Radiol , vol.80 , pp. 466-468
    • Schmit, P.1    Hautefort, P.2    Raison-Boulley, A.M.3
  • 8
    • 0034101643 scopus 로고    scopus 로고
    • Ultrasound imaging of forearm fractures in children: A viable alternative?
    • Williamson D, Watura R, Cobby M. Ultrasound imaging of forearm fractures in children: a viable alternative? J Accid Emerg Med 2000 17 22-24
    • (2000) J Accid Emerg Med , vol.17 , pp. 22-24
    • Williamson, D.1    Watura, R.2    Cobby, M.3
  • 9
    • 4644243835 scopus 로고    scopus 로고
    • Handheld ultrasound diagnosis of extremity fractures
    • Brooks A J., Price V, Simms M et al. Handheld ultrasound diagnosis of extremity fractures. J R Army Med Corps 2004 150 78-80
    • (2004) J R Army Med Corps , vol.150 , pp. 78-80
    • Brooks, A.J.1    Price, V.2    Simms, M.3
  • 10
    • 0242267523 scopus 로고    scopus 로고
    • Sonographische Beurteilung von supracondylären Humerusfrakturen
    • Pistor G, Graffstadt H. Sonographische Beurteilung von supracondylären Humerusfrakturen. Ultraschall in Med 2003 24 331-339
    • (2003) Ultraschall in Med , vol.24 , pp. 331-339
    • Pistor, G.1    Graffstadt, H.2
  • 11
    • 0036103429 scopus 로고    scopus 로고
    • Occult fractures of the waist of the scaphoid: Early diagnosis by high-spatial resolution sonography
    • Hauger O, Bonnefoy O, Moinard M et al. Occult fractures of the waist of the scaphoid: early diagnosis by high-spatial resolution sonography. AJR 2002 178 1239-1245
    • (2002) AJR , vol.178 , pp. 1239-1245
    • Hauger, O.1    Bonnefoy, O.2    Moinard, M.3
  • 12
    • 45949110813 scopus 로고    scopus 로고
    • Ultrasound in Diagnosis of Fractures in Children: Unnecessary Harassment or Useful Addition to X-ray?
    • Moritz J D., Berthold L D., Soenksen S F. et al. Ultrasound in Diagnosis of Fractures in Children: Unnecessary Harassment or Useful Addition to X-ray? Ultraschall in Med 2008 29 267-274
    • (2008) Ultraschall in Med , vol.29 , pp. 267-274
    • Moritz, J.D.1    Berthold, L.D.2    Soenksen, S.F.3
  • 13
    • 2442712696 scopus 로고    scopus 로고
    • Ultrasound for the early diagnosis of clinically suspected scaphoid fracture
    • Senall J A., Failla J M., Bouffard J A. et al. Ultrasound for the early diagnosis of clinically suspected scaphoid fracture. J Hand Surg 2004 29 400-405
    • (2004) J Hand Surg , vol.29 , pp. 400-405
    • Senall, J.A.1    Failla, J.M.2    Bouffard, J.A.3
  • 14
    • 0033652394 scopus 로고    scopus 로고
    • Ultrasound in the diagnosis of fractures in children
    • Hübner U, Schlicht W, Outzen S et al. Ultrasound in the diagnosis of fractures in children. J Bone Joint Surg Br 2000 82 1170-1173
    • (2000) J Bone Joint Surg Br , vol.82 , pp. 1170-1173
    • Hübner, U.1    Schlicht, W.2    Outzen, S.3
  • 15
    • 0345517138 scopus 로고    scopus 로고
    • Sonographic management of infantile clavicular fractures
    • Blab E, Geissler W, Rokitansky A. Sonographic management of infantile clavicular fractures. Pediatr Surg Int 1999 15 251-254
    • (1999) Pediatr Surg Int , vol.15 , pp. 251-254
    • Blab, E.1    Geissler, W.2    Rokitansky, A.3
  • 16
    • 84946655115 scopus 로고
    • On simultaneous confidence intervals for multinomial proportions
    • Goodman L A. On simultaneous confidence intervals for multinomial proportions. Technometrics 1965 7 247-254
    • (1965) Technometrics , vol.7 , pp. 247-254
    • Goodman, L.A.1
  • 17
    • 84981981465 scopus 로고
    • A test for homogeneity of the marginal distribution in a two-way classification
    • Stuart A. A test for homogeneity of the marginal distribution in a two-way classification. Biometrika 1955 42 412-416
    • (1955) Biometrika , vol.42 , pp. 412-416
    • Stuart, A.1
  • 19
    • 0030884070 scopus 로고    scopus 로고
    • Ultraschalldiagnostik von Rippen- und Sternumfrakturen
    • Bitschnau R, Gehmacher O, Kopf A et al. Ultraschalldiagnostik von Rippen- und Sternumfrakturen. Ultraschall in Med 1997 18 158-161
    • (1997) Ultraschall in Med , vol.18 , pp. 158-161
    • Bitschnau, R.1    Gehmacher, O.2    Kopf, A.3
  • 21
    • 1542780644 scopus 로고    scopus 로고
    • Potentials of ultrasound in the diagnosis of midfacial fractures
    • Friedrich R E., Heiland M, Bartel-Friedrich S. Potentials of ultrasound in the diagnosis of midfacial fractures. Clin Oral Invest 2003 7 226-229
    • (2003) Clin Oral Invest , vol.7 , pp. 226-229
    • Friedrich, R.E.1    Heiland, M.2    Bartel-Friedrich, S.3
  • 22
    • 0033785398 scopus 로고    scopus 로고
    • Assessment of zygomatico-orbital complex fractures using ultrasonography
    • McCann P J., Brocklebank L M., Ayoub A F. Assessment of zygomatico-orbital complex fractures using ultrasonography. Br J Maxillofac Surg 2000 38 525-529
    • (2000) Br J Maxillofac Surg , vol.38 , pp. 525-529
    • McCann, P.J.1    Brocklebank, L.M.2    Ayoub, A.F.3
  • 23
    • 0034183353 scopus 로고    scopus 로고
    • US versus conventional radiography in the diagnosis of sternal fractures
    • Engin G, Yekeler E, Guloglu R et al. US versus conventional radiography in the diagnosis of sternal fractures. Acta Radiol 2000 41 296-299
    • (2000) Acta Radiol , vol.41 , pp. 296-299
    • Engin, G.1    Yekeler, E.2    Guloglu, R.3
  • 24
    • 0028835284 scopus 로고
    • Diagnostic value of ultrasonography and conventional radiography for the assessment of sternal fractures
    • Hendrich C, Finkewitz U, Berner W. Diagnostic value of ultrasonography and conventional radiography for the assessment of sternal fractures. Injury 1995 26 601-604
    • (1995) Injury , vol.26 , pp. 601-604
    • Hendrich, C.1    Finkewitz, U.2    Berner, W.3
  • 25
    • 0023735641 scopus 로고
    • Sonographic detection of occult bone fractures
    • Graif M, Stahl-Kent V, Ben-Ami T et al. Sonographic detection of occult bone fractures. Pediatr Radiol 1988 18 383-385
    • (1988) Pediatr Radiol , vol.18 , pp. 383-385
    • Graif, M.1    Stahl-Kent, V.2    Ben-Ami, T.3
  • 26
    • 0034973336 scopus 로고    scopus 로고
    • Scaphoid fractures: Evaluation with high-spatial-resolution US Initial results
    • Herneth A M., Siegmeth A, Bader T R. et al. Scaphoid fractures: Evaluation with high-spatial-resolution US Initial results. Radiology 2001 220 231-235
    • (2001) Radiology , vol.220 , pp. 231-235
    • Herneth, A.M.1    Siegmeth, A.2    Bader, T.R.3
  • 27
    • 27644538913 scopus 로고    scopus 로고
    • Sonographic detection of radiographically occult fractures in paediatric ankle injuries
    • Simanovsky N, Hiller N, Leibner E et al. Sonographic detection of radiographically occult fractures in paediatric ankle injuries. Pediatr Radiol 2003 35 1062-1065
    • (2003) Pediatr Radiol , vol.35 , pp. 1062-1065
    • Simanovsky, N.1    Hiller, N.2    Leibner, E.3
  • 28
    • 0032870607 scopus 로고    scopus 로고
    • Sonographic detection of occult fractures in the foot and ankle
    • Wang C L., Shieh J Y., Wang T G. et al. Sonographic detection of occult fractures in the foot and ankle. J Clin Ultrasound 1999 27 421-425
    • (1999) J Clin Ultrasound , vol.27 , pp. 421-425
    • Wang, C.L.1    Shieh, J.Y.2    Wang, T.G.3
  • 30
    • 0029142897 scopus 로고
    • Sonographie geburtstraumatischer Extremitätenläsionen
    • Riebel T, Nasir R. Sonographie geburtstraumatischer Extremitä tenläsionen. Ultraschall in Med 1995 16 196-199
    • (1995) Ultraschall in Med , vol.16 , pp. 196-199
    • Riebel, T.1    Nasir, R.2
  • 31
    • 33646577848 scopus 로고    scopus 로고
    • Sonographic diagnosis in toddlers fracture in the emergency department
    • Lewis D, Logan P. Sonographic diagnosis in toddlers fracture in the emergency department. J Clin Ultrasound 2006 34 190-194
    • (2006) J Clin Ultrasound , vol.34 , pp. 190-194
    • Lewis, D.1    Logan, P.2
  • 32
    • 34548312132 scopus 로고    scopus 로고
    • Diagnosis and guided reduction of forearm fractures in children using bedside ultrasound
    • Chen L, Kim Y, Moore C L. Diagnosis and guided reduction of forearm fractures in children using bedside ultrasound. Pediatr Emerg Care 2007 23 528-531
    • (2007) Pediatr Emerg Care , vol.23 , pp. 528-531
    • Chen, L.1    Kim, Y.2    Moore, C.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.