Volumn 26, Issue 2, 2010, Pages 217-221

Performance analysis of three-stage liquid desiccant deep dehumidification processor driven by heat pump

Author keywords

Air conditioning; Deep dehumidification; Liquid desiccant; Performance test

Indexed keywords

AIR HUMIDITY RATIO; COEFFICIENT OF PERFORMANCE; DRY STATE; EXHAUST AIR; HEAT PUMPS; HUMID AIR; LIQUID DESICCANT; LIQUID PIPELINES; LITHIUM BROMIDE; OUTDOOR AIR; OUTDOOR-AIR TEMPERATURE; PERFORMANCE ANALYSIS; PERFORMANCE TESTS; SIMULATION RESULT; SUPPLY AIR TEMPERATURE; TEST RESULTS;

EID: 77955255764     PISSN: 10037985     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (7)
  • 1
    • 38949187716 scopus 로고    scopus 로고
    • Liquid desiccant air-conditioning system and its applications
    • in Chinese
    • Jiang Y, Li Z, Chen X Y, et al. Liquid desiccant air-conditioning system and its applications[J]. Heating Ventilation and Air Conditioning, 2004, 34(11): 88-97.(in Chinese)
    • (2004) Heating Ventilation and Air Conditioning , vol.34 , Issue.11 , pp. 88-97
    • Jiang, Y.1    Li, Z.2    Chen, X.Y.3
  • 2
    • 4544295327 scopus 로고    scopus 로고
    • Experimental study on the performance of liquid desiccant cooling air conditioning with energy storage
    • in Chinese
    • Zhang X S, Yin Y G, Cao Y R. Experimental study on the performance of liquid desiccant cooling air conditioning with energy storage[J]. Journal of Engineering Thermophysics, 2004, 25(4): 546-549.(in Chinese)
    • (2004) Journal of Engineering Thermophysics , vol.25 , Issue.4 , pp. 546-549
    • Zhang, X.S.1    Yin, Y.G.2    Cao, Y.R.3
  • 3
    • 37849188544 scopus 로고    scopus 로고
    • A new heat pump desiccant dehumidifier for supermarket application
    • Lazzarin R M, Castellotti F. A new heat pump desiccant dehumidifier for supermarket application[J]. Energy and Buildings, 2007, 39(1): 59-65.
    • (2007) Energy and Buildings , vol.39 , Issue.1 , pp. 59-65
    • Lazzarin, R.M.1    Castellotti, F.2
  • 4
    • 77955234824 scopus 로고    scopus 로고
    • Liquid desiccant total heat exchanger and heat pump combined fresh air handling units
    • in Chinese
    • Liu X H, Li Z, Jiang Y. Liquid desiccant total heat exchanger and heat pump combined fresh air handling units[J]. Heating Ventilation and Air Conditioning, 2004, 34(11): 98-102.(in Chinese)
    • (2004) Heating Ventilation and Air Conditioning , vol.34 , Issue.11 , pp. 98-102
    • Liu, X.H.1    Li, Z.2    Jiang, Y.3
  • 5
    • 77955241759 scopus 로고    scopus 로고
    • System principle and performance tests of heat pump two-stage liquid desiccant outdoor air handler
    • in Chinese
    • Liu S Q, Liu X H, Jiang Y. System principle and performance tests of heat pump two-stage liquid desiccant outdoor air handler[J]. Heating Ventilation and Air Conditioning, 2008, 38(1): 54-63.(in Chinese)
    • (2008) Heating Ventilation and Air Conditioning , vol.38 , Issue.1 , pp. 54-63
    • Liu, S.Q.1    Liu, X.H.2    Jiang, Y.3
  • 6
    • 77955250845 scopus 로고    scopus 로고
    • Handbook of heat pump driven liquid desiccant deep dehumidification processor
    • Beijing Sinorefine Ltd, 2009-04-15
    • Beijing Sinorefine Ltd. Handbook of heat pump driven liquid desiccant deep dehumidification processor[EB/OL]. [2009-04-15]. http://www.sinorefine.com.cn.
  • 7
    • 77955244269 scopus 로고    scopus 로고
    • Simulation method and application of liquid desiccant air conditioning system
    • in Chinese
    • Liu S Q, Liu X H, Jiang Y. Simulation method and application of liquid desiccant air conditioning system[J]. Special Topic on Air-Conditioning, 2006(5): 49-52.(in Chinese)
    • (2006) Special Topic on Air-Conditioning , Issue.5 , pp. 49-52
    • Liu, S.Q.1    Liu, X.H.2    Jiang, Y.3