Volumn 15, Issue 8, 2010, Pages 451-458

Development of caprine liver quality control materials for trace element analysis of biological tissues

Author keywords

Aluminum; ETAAS; ICP MS; Lanthanides; Mercury; Metals; Secondary reference materials

Indexed keywords


EID: 77955226158     PISSN: 09491775     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00769-010-0660-2     Document Type: Article
Times cited : (9)

References (13)
  • 1
    • 1542379761 scopus 로고    scopus 로고
    • Traceability of environmental chemical measurements
    • Quevauviller P (2004) Traceability of environmental chemical measurements. Trends Anal Chem 23: 171-177.
    • (2004) Trends Anal Chem , vol.23 , pp. 171-177
    • Quevauviller, P.1
  • 2
    • 0030830529 scopus 로고    scopus 로고
    • Comparability and traceability in analytical measurements and reference materials
    • Thompson M (1997) Comparability and traceability in analytical measurements and reference materials. Analyst 122: 1201-1205.
    • (1997) Analyst , vol.122 , pp. 1201-1205
    • Thompson, M.1
  • 3
    • 0032822186 scopus 로고    scopus 로고
    • Moving from official to traceable methods
    • Walsh MC (1999) Moving from official to traceable methods. Trends Anal Chem 18: 616-623.
    • (1999) Trends Anal Chem , vol.18 , pp. 616-623
    • Walsh, M.C.1
  • 4
    • 77955202294 scopus 로고    scopus 로고
    • Joint Committee for Guides in Metrology (JCGM) (2008) International vocabulary of metrology-basic and general concepts and associated terms (VIM).
  • 5
    • 0026576376 scopus 로고
    • Monitoring human exposure to lead: An assessment of current laboratory performance for the determination of blood lead
    • Parsons PJ (1992) Monitoring human exposure to lead: an assessment of current laboratory performance for the determination of blood lead. Environ Res 57: 149-162.
    • (1992) Environ Res , vol.57 , pp. 149-162
    • Parsons, P.J.1
  • 7
    • 46249095513 scopus 로고    scopus 로고
    • Development of candidate reference materials for the measurement of lead in bone
    • Hetter KM, Bellis DJ, Geraghty C, Todd AC, Parsons PJ (2008) Development of candidate reference materials for the measurement of lead in bone. Anal Bioanal Chem 391: 2011-2021.
    • (2008) Anal Bioanal Chem , vol.391 , pp. 2011-2021
    • Hetter, K.M.1    Bellis, D.J.2    Geraghty, C.3    Todd, A.C.4    Parsons, P.J.5
  • 8
    • 39749188325 scopus 로고    scopus 로고
    • Characterization of candidate reference materials for bone lead via interlaboratory study and double isotope dilution mass spectrometry
    • Bellis DJ, Hetter KM, Verostek MF, Parsons PJ (2008) Characterization of candidate reference materials for bone lead via interlaboratory study and double isotope dilution mass spectrometry. J Anal Atom Spectrom 23: 298-308.
    • (2008) J Anal Atom Spectrom , vol.23 , pp. 298-308
    • Bellis, D.J.1    Hetter, K.M.2    Verostek, M.F.3    Parsons, P.J.4
  • 9
    • 0030198763 scopus 로고    scopus 로고
    • Microwave digestion of biological samples with tetramethylammonium hydroxide and ethylenediaminetetraacetic acid for element determination
    • Zhou CY, Wong MK, Koh LL, Wee YC (1996) Microwave digestion of biological samples with tetramethylammonium hydroxide and ethylenediaminetetraacetic acid for element determination. Talanta 43: 1061-1068.
    • (1996) Talanta , vol.43 , pp. 1061-1068
    • Zhou, C.Y.1    Wong, M.K.2    Koh, L.L.3    Wee, Y.C.4
  • 10
    • 0034878788 scopus 로고    scopus 로고
    • A new test for 'sufficient homogeneity
    • Fearn T, Thompson M (2001) A new test for 'sufficient homogeneity'. Analyst 126: 1414-1417.
    • (2001) Analyst , vol.126 , pp. 1414-1417
    • Fearn, T.1    Thompson, M.2
  • 11
    • 77955185218 scopus 로고    scopus 로고
    • Joint Committee for Guides in Metrology (JCGM) (2008) Evaluation of measurement data-guide to the expression of uncertainty in measurement (GUM). First edn.
  • 12
    • 77955217166 scopus 로고    scopus 로고
    • Eurolab (2007) Measurement uncertainty revisited: alternative approaches to uncertainty evaluation (Technical Report No. 1/2007).
  • 13
    • 0036310862 scopus 로고    scopus 로고
    • Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC Technical Report)
    • Thompson M, Ellison SLR, Wood R (2002) Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC Technical Report). Pure Appl Chem 74: 835-855.
    • (2002) Pure Appl Chem , vol.74 , pp. 835-855
    • Thompson, M.1    Ellison, S.L.R.2    Wood, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.